Wed Dec 19 17:47:02 2018, anchal, DailyProgress, TempCtrl, Cavity Temperature Sensor Circuit v1.1
|
Mon Dec 24 16:52:26 2018, rana, DailyProgress, TempCtrl, Cavity Temperature Sensor Circuit v1.1
|
Tue Jan 29 17:47:14 2019, anchal, DailyProgress, TempCtrl, Cavity Temperature Sensor Breadboard Circuit Noise Analysis 
|
Wed Jan 30 12:17:05 2019, rana, DailyProgress, TempCtrl, Cavity Temperature Sensor Breadboard Circuit Noise Analysis
|
|
Message ID: 2299
Entry time: Wed Jan 30 12:17:05 2019
In reply to: 2298
|
Author: |
rana |
Type: |
DailyProgress |
Category: |
TempCtrl |
Subject: |
Cavity Temperature Sensor Breadboard Circuit Noise Analysis |
|
|
that's a good start, but we don't care about the noise above 10 Hz. So you should re-take the data and plot from 1 mHz to 10 Hz. Instead of using SR785, just record the time series on a cymac somewhere. You can run a cable into Gabriele's lab if you have to. |