Message ID: 2223
Entry time: Wed Aug 1 17:31:19 2018
In reply to: 2222
Reply to this: 2224
2225
|
Author: |
awade |
Type: |
DailyProgress |
Category: |
ISS |
Subject: |
Final Design for ISS Servo v3.2 |
|
|
AD743 is discontinued. We have a few in stock, and there are still a few SOIC-16 version that you can buy.
But better to design with a op amp that is replaceable into the future.
Quote: |
I checked with some replacements of opamp at stage 1 to reduce the noise due to current noise. It seems AD743 is the best balanced opamp for this location. Attached is the circuit schematic of this final version v3.2 , with LISO analysis and also the analysis done to reach to this opamp.
|
|