Message ID: 207     Entry time: Sun Jul 11 00:52:14 2010
Author: Megan 
Type: Summary 
Category: VCO 
Subject: VCO Noise 

I graphed the VCO phase noise with the previously measured data - the data I have seems to be a bit higher. I also converted the phase noise into frequency noise for both VCOs and the previous measurement. Just for reference, "VCO 1" is the one that we were measuring the noise of the different parts of the VCO and that has its lid off.  "VCO 2" is the one we brought over from the PSL lab that is currently still in one piece.

Attachment 1: PhaseNoisePreviousMeasure.png  20 kB  | Hide | Hide all
PhaseNoisePreviousMeasure.png
Attachment 2: FrequencyNoisePreviousMeasure.png  17 kB  | Hide | Hide all
FrequencyNoisePreviousMeasure.png