Author: Kira, Craig 
Type: DailyProgress 
Category: TempCtrl 
Subject: heating/cooling data fitting 

Yeah, that's what I'm using.

Quote:

What model are you using to fit this?  What is p0, popt, or pcov? 

I looked at the curve_fit tutorial, so it seems like your model is:

$M(x, \alpha, \beta, \gamma) = \alpha \exp{(-\beta x)} + \gamma$

where x is your data,  \alpha, \beta, and \gamma are your model parameters, p0 are your initial parameter values, popt are you optimal model fit values, and pcov is your covariance matrix.

Quote:

I fit the data that Kevin and I gathered a while ago for the heating/cooling test we performed.

 

 