40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Entry  Mon Apr 3 21:52:50 2017, Craig and Andrew, DailyProgress, BEAT, Transmission Beat Note Achieved + Visibility and Power Measurements 
    Reply  Tue Apr 4 17:32:40 2017, rana, DailyProgress, BEAT, Transmission Beat Note Achieved + Visibility and Power Measurements 
Message ID: 1834     Entry time: Tue Apr 4 17:32:40 2017     In reply to: 1833
Author: rana 
Type: DailyProgress 
Category: BEAT 
Subject: Transmission Beat Note Achieved + Visibility and Power Measurements 

That plot was so bad, I had to delete it. No ticks or labels on the x-axis !  This is supposed to be science, not performance art.

If you have ~0.5 mW in each beam, and the RF transimpedance of the 1811 is 40 kOhms, you should be getting a HUGE beat signal. It should saturate the 1811.