40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Entry  Sun Aug 14 21:24:11 2016, awade, Misc, TempCtrl, Kapton stick on resistive heaters 
    Reply  Thu Aug 25 07:36:06 2016, rana, Misc, TempCtrl, Kapton stick on resistive heaters 
       Reply  Tue Aug 30 10:28:07 2016, Aidan, Misc, TempCtrl, Kapton stick on resistive heaters 
          Reply  Mon Sep 26 19:52:52 2016, awade & Aidan, Misc, Documentation, Heat shields arrived, checked 20160926_New1.45inchRefCavShieldsAndCaps.zip
             Reply  Tue Sep 27 10:05:36 2016, awade & Aidan, Misc, Documentation, Heat shields arrived, checked 
Message ID: 1706     Entry time: Sun Aug 14 21:24:11 2016     Reply to this: 1707
Author: awade 
Type: Misc 
Category: TempCtrl 
Subject: Kapton stick on resistive heaters 

 

Edit: Datasheet was removed.

We have some kapton heaters, I found them in a draw when cleaning. These should be useful for our new shield temperature control.

These are from the kit KH-KIT-EFH-15001.  I don't know how old they are or if Kapton stickiness goes off, but here is a list of remaining available sick on resistive heaters and their Ohmage:​

Kapton resistive heaters in stock
Quantity Dimensions  Resistance [Ohm] Shape
1 0.75"x2.5" 23.5 Rectangular
1 0.75"x3.25" 33.2 Rectangular
1 1"x3" 40 Rectangular
2 2"x3" 103.7 Rectangular
2 2.5"x2.5" 108.6 Rectangular
2 1.5"x8" 252.0 Rectangular
3 3"x3" 153.7 Rectangular
1 1.5"x4.5" 120.3 Rectangular
1 6"x1" ? Rectangular
2 1.5"D 32.8 Circular
1 2"D 59.4 Circular
1 3"D 169.0 Circular

 

Data sheet is attached. Note that heating ranges from 3-8 W per square inch at the 12 V supply level for various different choices of shape and wire pattern.

 

ELOG V3.1.3-