As we are doing mode matching I compiled a list of presently available lenses to save time looking or ordering. See below.
A dynamically updated version is here: https://docs.google.com/spreadsheets/d/1x4-VQ85Wl7kGUH-V7HffCr6B7wIcD1y3VxXO4j6H5T0/edit?usp=sharing (this may not be a stable link far into the future)
At the time of posting the list is as follows:
Code |
Vendor |
Type |
ROC1 |
ROC2 |
n |
f |
location |
note |
KBC040 |
Newport |
Bi-Concave |
|
|
|
-75.00 |
40m |
|
KBC043 |
Newport |
Bi-Concave |
|
|
|
-50.00 |
40m |
|
KBC046 |
Newport |
Bi-Concave |
|
|
|
-25.00 |
40m |
|
KBX043 |
Newport |
Bi-Convex |
|
|
|
19.00 |
40m |
|
KBX046 |
Newport |
Bi-Convex |
|
|
|
25.40 |
40m |
|
KBX064 |
Newport |
Bi-Convex |
|
|
|
100.00 |
40m |
|
KBX064.AR.33 |
Newport |
Bi-Convex |
|
|
|
100.00 |
40m |
|
KBX088 |
Newport |
Bi-Convex |
|
|
|
1000.00 |
40m |
|
KPC028 |
Newport |
Plano-Concave |
|
|
|
-200.00 |
40m |
|
KPC031 |
Newport |
Plano-Concave |
|
|
|
-150.00 |
40m |
|
KPC034 |
Newport |
Plano-Concave |
|
|
|
-100.00 |
40m |
|
KPC037 |
Newport |
Plano-Concave |
|
|
|
-75.00 |
40m |
|
KPC043 |
Newport |
Plano-Concave |
|
|
|
-25.00 |
40m |
|
KPX076 |
Newport |
Plano-Convex |
|
|
|
25.00 |
40m |
|
KPX079AR.18 PCX Lens, BK7 |
Newport |
Plano-Convex |
|
|
|
38.10 |
40m |
|
KPX115AR.33 PCX BK7 |
Newport |
Plano-Convex |
|
|
|
400.00 |
40m |
|
LA1172-C |
Thorlabs |
Plano-Convex |
|
|
|
400.00 |
40m |
Thorlabs pre-mounted |
LA1464-C |
Thorlabs |
Plano-Convex |
|
|
|
1000.00 |
40m |
Thorlabs pre-mounted |
LA1484-C |
Thorlabs |
Plano-Convex |
|
|
|
300.00 |
40m |
Thorlabs pre-mounted |
LA1509-C |
Thorlabs |
Plano-Convex |
|
|
|
100.00 |
40m |
Thorlabs pre-mounted |
LA1908-C |
Thorlabs |
Plano-Convex |
|
|
|
500.00 |
40m |
Thorlabs pre-mounted |
LA1951-C |
Thorlabs |
Plano-Convex |
|
|
|
25.40 |
40m |
Thorlabs pre-mounted |
LA1978-C |
Thorlabs |
Plano-Convex |
|
|
|
750.00 |
40m |
Thorlabs pre-mounted |
LB1056-C |
Thorlabs |
Bi-Convex |
|
|
|
250.00 |
40m |
Thorlabs pre-mounted |
LB1391-C |
Thorlabs |
Bi-Convex |
|
|
|
400.00 |
40m |
Thorlabs pre-mounted |
LB1409-C |
Thorlabs |
Bi-Convex |
|
|
|
1000.00 |
40m |
Thorlabs pre-mounted |
LB1471-C |
Thorlabs |
Bi-Convex |
|
|
|
50.00 |
40m |
Thorlabs pre-mounted |
LB1475-C |
Thorlabs |
Bi-Convex |
|
|
|
750.00 |
40m |
Thorlabs pre-mounted |
LB1761-C |
Thorlabs |
Bi-Convex |
|
|
|
25.40 |
40m |
Thorlabs pre-mounted |
LB1779-C |
Thorlabs |
Bi-Convex |
|
|
|
300.00 |
40m |
Thorlabs pre-mounted |
LB1869-C |
Thorlabs |
Bi-Convex |
|
|
|
500.00 |
40m |
Thorlabs pre-mounted |
LB1901-C |
Thorlabs |
Bi-Convex |
|
|
|
75.00 |
40m |
Thorlabs pre-mounted |
LB1904-C |
Thorlabs |
Bi-Convex |
|
|
|
125.00 |
40m |
Thorlabs pre-mounted |
LC1715-C |
Thorlabs |
Plano-Concave |
|
|
|
-50.00 |
40m |
Thorlabs pre-mounted |
LC2297-C |
Thorlabs |
Plano-Concave |
|
|
|
-25.00 |
40m |
Thorlabs pre-mounted |
LC2679-C |
Thorlabs |
Plano-Concave |
|
|
|
-30.00 |
40m |
Thorlabs pre-mounted |
LD1170-C |
Thorlabs |
Bi-Concave |
|
|
|
-75.00 |
40m |
Thorlabs pre-mounted |
LD1464-C |
Thorlabs |
Bi-Concave |
|
|
|
-50.00 |
40m |
Thorlabs pre-mounted |
LD2297-C |
Thorlabs |
Bi-Concave |
|
|
|
-25.00 |
40m |
Thorlabs pre-mounted |
PLCX-25.4-103-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
103 |
1.44963 |
229.08 |
PSL |
|
PLCX-25.4-103.0-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
103 |
1.44963 |
229.08 |
40m |
|
PLCX-25.4-1030.2-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
1030.2 |
1.44963 |
2291.22 |
40m |
|
PLCX-25.4-12.9-C-1064 |
CVI |
Plano-Convex |
1.00E+99 |
12.9 |
1.5066 |
25.46 |
40m |
|
PLCX-25.4-13.1-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
13.1 |
1.44963 |
29.14 |
40m |
(Chipped) |
PLCX-25.4-154.5-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
154.5 |
1.44963 |
343.62 |
PSL |
|
PLCX-25.4-1545.0-C-633-1064 |
CVI |
Plano-Convex |
1.00E+99 |
1545 |
1.5066 |
3049.74 |
40m |
|
PLCX-25.4-180.3-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
180.3 |
1.44963 |
401.00 |
PSL |
|
PLCX-25.4-180.3-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
180.3 |
1.44963 |
401.00 |
PSL |
|
PLCX-25.4-20.6-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
20.6 |
1.44963 |
45.82 |
PSL |
|
PLCX-25.4-257.5-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
257.5 |
1.44963 |
572.69 |
PSL |
|
PLCX-25.4-257.5-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
257.5 |
1.44963 |
572.69 |
PSL |
|
PLCX-25.4-257.5-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
257.5 |
1.44963 |
572.69 |
PSL |
|
PLCX-25.4-2575-C-1064 |
CVI |
Plano-Convex |
1.00E+99 |
2575 |
1.5066 |
5082.91 |
40m |
|
PLCX-25.4-309.1-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
309.1 |
1.44963 |
687.45 |
PSL |
|
PLCX-25.4-309.1-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
309.1 |
1.44963 |
687.45 |
PSL |
|
PLCX-25.4-309.1-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
309.1 |
1.44963 |
687.45 |
PSL |
|
PLCX-25.4-357.5-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
357.5 |
1.44963 |
795.10 |
PSL |
|
PLCX-25.4-38.6-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
38.6 |
1.44963 |
85.85 |
PSL |
|
PLCX-25.4-46.4-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
46.4 |
1.44963 |
103.20 |
PSL |
|
PLCX-25.4-46.4-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
46.4 |
1.44963 |
103.20 |
PSL |
|
PLCX-25.4-51.5-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
51.5 |
1.44963 |
114.54 |
PSL |
|
PLCX-25.4-515.1-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
515.1 |
1.44963 |
1145.61 |
PSL |
|
PLCX-25.4-64.4-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
64.4 |
1.44963 |
143.23 |
PSL |
|
PLCX-25.4-77.3-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
77.3 |
1.44963 |
171.92 |
40m |
|
PLCX-25.4-77.3-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
77.3 |
1.44963 |
171.92 |
40m |
|
PLCX-25.4-772.6-UV-1064 |
CVI |
Plano-Convex |
1.00E+99 |
772.6 |
1.44963 |
1718.30 |
40m |
|
SPX028AR.1 PLXLens, UV |
Newport |
Plano-Convex |
|
|
|
200.00 |
40m |
|
Unspecified |
Unspecified |
Unspecified |
|
|
|
100.00 |
40m |
|
|