Message ID: 1624     Entry time: Wed Apr 6 15:02:50 2016     In reply to: 1623     Reply to this: 1627
Author: tara 
Type: DailyProgress 
Category: PMC 
Subject: test on new PMC 
  • Note: V input for RFPD should be +/- 15 V (schematic)
  • Power for driving 21.5 MHz resonant EOM, can be up to 20 dBm , PSL:791 (seems that we have used only 9 dBm from the LO driver card, PSL:1092 )
  • power for mixer (LO) , 23 dBm ( Minicircuit Ray-3, see the schematic)
  • Schematic for LO for PMC , DCC
ELOG V3.1.3-