40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Message ID: 1561     Entry time: Tue Aug 4 14:15:14 2015
Author: Aidan 
Type: Summary 
Category: Computers 
Subject: DAQD not running on FB2. FB2 trend disk is full 

Like the title says ...

If I try running DAQD per https://nodus.ligo.caltech.edu:30889/ATFWiki/doku.php?id=main:experiments:psl:add_channel_for_daq_in_fb2

then it fails and the log file reveals that this is when it tries to write a GWF file to the trend folder. Manually trying to write anything to this location results in a "disk full" message.

The trusty df command yields the following.

[controls@fb2 frames]$ df
Filesystem           1K-blocks      Used Available Use% Mounted on
/dev/mapper/VolGroup00-LogVol00
                     232477448 125679200  94798608  58% /
/dev/sda1               101086     25961     69906  28% /boot
tmpfs                  1029664         0   1029664   0% /dev/shm
/dev/sdc1            240362656 205728852  34633804  86% /frames/full
/dev/sdd1            307663800 307663800         0 100% /frames/trend

 

 

ELOG V3.1.3-