40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Entry  Sat Aug 2 23:07:39 2014, Evan, Notes, NoiseBudget, AlGaAs python noise budget noiseBudget.pdf
    Reply  Wed Aug 20 19:00:03 2014, Evan, Notes, NoiseBudget, AlGaAs python noise budget noiseBudget.pdf
       Reply  Mon Aug 25 20:54:38 2014, Evan, Notes, NoiseBudget, AlGaAs python noise budget: TO implemented noiseBudget.pdf
Message ID: 1464     Entry time: Sat Aug 2 23:07:39 2014     Reply to this: 1482
Author: Evan 
Type: Notes 
Category: NoiseBudget 
Subject: AlGaAs python noise budget 

I have started a python implementation of the AlGaAs noise budget. All parameters, functions, etc. are defined in a single notebook, and this same notebook generates the plot. The python uncertainties package facilitates estimation of uncertainties in material parameters, optical parameters, etc.

Currently, the coating thermo-optic trace is not an actual calculation; it is just a flat line culled from figure 5.9 of Tara's thesis.

The PDH shot noise trace is shown assuming an incident power of 1 mW on each cavity, a PDH modulation index of 0.2 rad, and a cavity visibility of 0.92.

Attachment 1: noiseBudget.pdf  674 kB  Uploaded Sun Aug 3 20:08:49 2014  | Show | Show all
ELOG V3.1.3-