40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Entry  Tue Jun 10 17:00:18 2014, tara, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters BRnoise_YLYH.pngBRnoise_YH.pngBRnoise_YL.pngBR_YH_correlate.pngYoungs_dep.m.zip
    Reply  Mon Jun 23 17:13:06 2014, tara, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters 
       Reply  Mon Jun 23 19:23:57 2014, rana, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters 
          Reply  Thu Jun 26 03:41:31 2014, tara, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters BNS.pngstrain.pngstrain.png
             Reply  Wed Jul 2 20:05:32 2014, tara, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters 6x
Message ID: 1433     Entry time: Mon Jun 23 19:23:57 2014     In reply to: 1432     Reply to this: 1436
Author: rana 
Type: Notes 
Category: NoiseBudget 
Subject: aLIGO Noise budget with uncertainties in material parameters 

 

 That GWINC link is more than a year old. You're best off just updating your CVS checkout of the code, or getting a new zip file from someone else if your CVS is broken. When I run gwinc with nomm.m, I get R_BNS = 189.5 Mpc.