I'm estimating the BNS range of aLIGO. Here is a quick note about the calculation.

  •  The range can be calculated by GWINC, more details about the calculation can be found in T090049
  •  This is for NS-NS (1.4M_solar) CBC.
  •  The change in sensitivity due to material parameters results in a different LIGO detection range.
  • One sigma here means one standard deviation. +/- one sigma cover 68% of the normal distribution. 

For example, the normal configuration for aLIGO will have BNS in spiral range equal to 178.29 Mpc (based on the current code available on gwinc.