Not logged in |
 |
|
Tue Jun 10 17:00:18 2014, tara, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters    
|
Mon Jun 23 17:13:06 2014, tara, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters
|
Mon Jun 23 19:23:57 2014, rana, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters
|
Thu Jun 26 03:41:31 2014, tara, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters  
|
Wed Jul 2 20:05:32 2014, tara, Notes, NoiseBudget, aLIGO Noise budget with uncertainties in material parameters 6x
|
|
Message ID: 1432
Entry time: Mon Jun 23 17:13:06 2014
In reply to: 1428
Reply to this: 1433
|
Author: |
tara |
Type: |
Notes |
Category: |
NoiseBudget |
Subject: |
aLIGO Noise budget with uncertainties in material parameters |
|
|
I'm estimating the BNS range of aLIGO. Here is a quick note about the calculation.
- The range can be calculated by GWINC, more details about the calculation can be found in T090049
- This is for NS-NS (1.4M_solar) CBC.
- The change in sensitivity due to material parameters results in a different LIGO detection range.
- One sigma here means one standard deviation. +/- one sigma cover 68% of the normal distribution.
For example, the normal configuration for aLIGO will have BNS in spiral range equal to 178.29 Mpc (based on the current code available on gwinc. |