40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
PSL |
Not logged in |
 |
|
Mon Jul 29 22:30:34 2013, tara, Notes, optic, coating optimization for AlGaAs    
|
Wed Jul 31 00:31:39 2013, tara, Notes, optic, coating optimization for AlGaAs
|
Fri Aug 9 17:58:01 2013, tara, Notes, optic, coating optimization for AlGaAs    
|
Tue Aug 27 16:11:26 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis 8x
|
Wed Aug 28 21:21:38 2013, tara, Notes, optic, GWINC for TO calculation: recap
|
Sun Sep 1 18:38:37 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis 7x
|
Mon Sep 2 18:31:46 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis
|
Wed Sep 18 21:55:11 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis
|
Thu Sep 19 20:38:17 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis
|
Fri Sep 20 19:26:45 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis   
|
Fri Sep 20 21:19:29 2013, Matt A., Notes, optic, coating optimization for AlGaAs:error analysis
|
Sat Sep 21 23:49:29 2013, rana, Notes, optic, coating optimization for AlGaAs:error analysis
|
Sun Sep 22 00:27:09 2013, some random goon, Notes, optic, coating optimization for AlGaAs:error analysis
|
Mon Sep 23 18:07:22 2013, rana, Notes, optic, coating optimization for AlGaAs:error analysis
|
Mon Sep 23 18:50:05 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis  
|
Thu Sep 26 23:25:40 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis 8x
|
Thu Oct 3 10:34:32 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis
|
Thu Oct 10 01:59:24 2013, tara, Notes, optic, coating optimization for AlGaAs:error analysis
|
Fri Oct 11 15:23:54 2013, tara, Notes, optic, coating optimization for AlGaAs:electric field in coating layer 6x
|
Mon Oct 14 21:02:00 2013, tara, Notes, optic, coating optimization for AlGaAs:variation in x
|
Sun Oct 27 20:12:25 2013, tara, Notes, optic, photothermal noise in AlGaAs 
|
Wed Dec 18 21:05:28 2013, tara, Notes, optic, photothermal noise in AlGaAs: thickness resolution 8x
|
Sat May 17 22:01:28 2014, tara, Notes, optic, Coating TO opt for Adv LIGO: ETM 7x
|
Sun May 18 10:45:42 2014, tara, Notes, optic, Coating TO opt for Adv LIGO   
|
Sat Jun 20 10:14:50 2015, Evan, Notes, optic, coating optimization for AlGaAs:electric field in coating layer
|
|
Message ID: 1359
Entry time: Thu Oct 3 10:34:32 2013
In reply to: 1356
Reply to this: 1363
|
Author: |
tara |
Type: |
Notes |
Category: |
optic |
Subject: |
coating optimization for AlGaAs:error analysis |
|
|
The new optimization is less sensitive to the values of refractive indices, but the overall error will not change much if other material parameters have the uncertainties as we estimate.
Summary: see update of error analysis in PSL:1356. The issues from the previous entry are cleared
- I made sure that the monte carlo tests were correct
- The new optimization (called opt4, and opt5) will make the TO noise level/Transmission less sensitive to nH and nL values. But with the current estimate of uncertainties in other parameters, the performance will be about the same to that of the original optimization (called opt1).
1) show error analysis |