40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Entry  Tue Jul 2 11:21:24 2013, Erica, DailyProgress, fiber optic, mode matching snip_of_beam_profiling_6_27.JPGP1020518.JPG
    Reply  Wed Jul 3 09:46:48 2013, Erica, DailyProgress, fiber optic, mode matching 130703-095332.jpg
       Reply  Thu Jul 11 01:40:19 2013, Erica, DailyProgress, fiber optic, mode matching P1020690.JPGP1020692.JPG
          Reply  Fri Jul 12 00:51:39 2013, Erica, Notes, fiber optic, mode matching P1020705.JPGP1020703.JPG7_11_13_beam_profile.PNG7_11_13_beam_from_fixed_lens.PNG
             Reply  Tue Jul 16 10:27:47 2013, Erica, Notes, fiber optic, mode matching, beam recombination 
                Reply  Tue Jul 16 11:02:47 2013, Erica, Notes, fiber optic, mode matching, beam recombination 130805-120628.jpg
                   Reply  Wed Jul 17 11:58:47 2013, Erica, Notes, fiber optic, mode matching, beam recombination 7_16_13_determining_polarization_axis.PNGTEK0000.PNG
                      Reply  Wed Jul 17 18:29:37 2013, Erica, DailyProgress, fiber optic, reducing drift in the recombined beam 
                         Reply  Sat Jul 20 23:39:09 2013, Erica, DailyProgress, fiber optic, reducing drift in the recombined beam 
                            Reply  Tue Jul 23 10:29:12 2013, Erica, DailyProgress, fiber optic, reducing drift in the recombined beam shielded_10s_TEK0005.PNGunshielded_10s_TEK0027.PNG
                               Reply  Tue Jul 23 11:43:00 2013, Evan, DailyProgress, Electronics Equipment, Zach's op-amp recommendations 
                               Reply  Fri Jul 26 11:07:44 2013, Erica, DailyProgress, BEAT, circuit for measuring temperature fluctations on CTN table P1030056.JPGP1030057.JPGP1030059.JPGP1030056.JPG
                                  Reply  Fri Jul 26 11:22:45 2013, Erica, DailyProgress, BEAT, circuit for measuring temperature fluctations on CTN table 
                                     Reply  Fri Jul 26 11:45:28 2013, Erica, DailyProgress, BEAT, circuit for measuring temperature fluctations on CTN table 
                                        Reply  Mon Jul 29 13:30:26 2013, Erica, DailyProgress, BEAT, adding resistor, capacitor, and sockets w_o_capacitor_7_26_13.JPGcapacitor_7_26_13.JPGP1030066.JPGP1030070.JPG
                                           Reply  Tue Jul 30 12:23:41 2013, Erica, DailyProgress, BEAT, addressed noise problem, DC signal 
                                              Reply  Thu Aug 1 00:25:02 2013, Erica, DailyProgress, fiber optic, insulating foam 731_7graph.PNG731_11graph.PNGP1030318.JPG
                                                 Reply  Fri Aug 2 12:38:41 2013, tara, DailyProgress, fiber optic, insulating foam chmbrtmp.JPGfringe.JPG
                                                    Reply  Tue Aug 6 12:31:24 2013, Erica, DailyProgress, fiber optic, insulating foam P1030403.JPG
                                                       Reply  Wed Aug 7 13:27:00 2013, Erica, DailyProgress, fiber optic, more foam, calculations for convertion from voltage to frequency P1030409.JPGP1030417.JPGP1030420.JPG
                                                          Reply  Wed Aug 7 18:53:20 2013, Erica, DailyProgress, fiber optic, noise budget, Matlab notes. noise_budget.PNGP1030427.JPG
                                                             Reply  Tue Aug 13 12:39:36 2013, Erica, DailyProgress, fiber optic, rewrote calculations for converting from voltage noise to frequency noise P1030458.JPGP1030459.JPGP1030460.JPG
                                                       Reply  Tue Aug 13 12:28:20 2013, Erica, Notes, Electronics Equipment, new AD 590 circuit and its noise calculation, beam alignment P1030461.JPGP1030454.JPGP1030456.JPGP1030457.JPGAD590circuit2.PNG
                                                          Reply  Fri Aug 16 10:35:44 2013, Erica, Notes, Electronics Equipment, AD590 msrmt, conversion to freq noise 
                   Reply  Tue Jul 30 16:19:32 2013, Erica, Notes, fiber optic, setup for beam recombination new_setup.PNGbeam_recombination2.PNG
                   Reply  Mon Aug 5 12:21:00 2013, Erica, Notes, fiber optic, calculation: phase change for fiber 130805-121449.jpg
    Reply  Tue Jul 30 15:48:47 2013, Erica, DailyProgress, fiber optic, noise for GYRO 
Message ID: 1296     Entry time: Tue Aug 13 12:39:36 2013     In reply to: 1286
Author: Erica 
Type: DailyProgress 
Category: fiber optic 
Subject: rewrote calculations for converting from voltage noise to frequency noise 
The equation for voltage is derived here: 1241
Attachment 1: P1030458.JPG  1.187 MB  | Show | Show all
Attachment 2: P1030459.JPG  3.340 MB  | Show | Show all
Attachment 3: P1030460.JPG  3.411 MB  | Show | Show all
ELOG V3.1.3-