40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  PSL  Not logged in ELOG logo
Entry  Tue Jul 2 11:21:24 2013, Erica, DailyProgress, fiber optic, mode matching snip_of_beam_profiling_6_27.JPGP1020518.JPG
    Reply  Wed Jul 3 09:46:48 2013, Erica, DailyProgress, fiber optic, mode matching 130703-095332.jpg
       Reply  Thu Jul 11 01:40:19 2013, Erica, DailyProgress, fiber optic, mode matching P1020690.JPGP1020692.JPG
          Reply  Fri Jul 12 00:51:39 2013, Erica, Notes, fiber optic, mode matching P1020705.JPGP1020703.JPG7_11_13_beam_profile.PNG7_11_13_beam_from_fixed_lens.PNG
             Reply  Tue Jul 16 10:27:47 2013, Erica, Notes, fiber optic, mode matching, beam recombination 
                Reply  Tue Jul 16 11:02:47 2013, Erica, Notes, fiber optic, mode matching, beam recombination 130805-120628.jpg
                   Reply  Wed Jul 17 11:58:47 2013, Erica, Notes, fiber optic, mode matching, beam recombination 7_16_13_determining_polarization_axis.PNGTEK0000.PNG
                      Reply  Wed Jul 17 18:29:37 2013, Erica, DailyProgress, fiber optic, reducing drift in the recombined beam 
                         Reply  Sat Jul 20 23:39:09 2013, Erica, DailyProgress, fiber optic, reducing drift in the recombined beam 
                            Reply  Tue Jul 23 10:29:12 2013, Erica, DailyProgress, fiber optic, reducing drift in the recombined beam shielded_10s_TEK0005.PNGunshielded_10s_TEK0027.PNG
                               Reply  Tue Jul 23 11:43:00 2013, Evan, DailyProgress, Electronics Equipment, Zach's op-amp recommendations 
                               Reply  Fri Jul 26 11:07:44 2013, Erica, DailyProgress, BEAT, circuit for measuring temperature fluctations on CTN table P1030056.JPGP1030057.JPGP1030059.JPGP1030056.JPG
                                  Reply  Fri Jul 26 11:22:45 2013, Erica, DailyProgress, BEAT, circuit for measuring temperature fluctations on CTN table 
                                     Reply  Fri Jul 26 11:45:28 2013, Erica, DailyProgress, BEAT, circuit for measuring temperature fluctations on CTN table 
                                        Reply  Mon Jul 29 13:30:26 2013, Erica, DailyProgress, BEAT, adding resistor, capacitor, and sockets w_o_capacitor_7_26_13.JPGcapacitor_7_26_13.JPGP1030066.JPGP1030070.JPG
                                           Reply  Tue Jul 30 12:23:41 2013, Erica, DailyProgress, BEAT, addressed noise problem, DC signal 
                                              Reply  Thu Aug 1 00:25:02 2013, Erica, DailyProgress, fiber optic, insulating foam 731_7graph.PNG731_11graph.PNGP1030318.JPG
                                                 Reply  Fri Aug 2 12:38:41 2013, tara, DailyProgress, fiber optic, insulating foam chmbrtmp.JPGfringe.JPG
                                                    Reply  Tue Aug 6 12:31:24 2013, Erica, DailyProgress, fiber optic, insulating foam P1030403.JPG
                                                       Reply  Wed Aug 7 13:27:00 2013, Erica, DailyProgress, fiber optic, more foam, calculations for convertion from voltage to frequency P1030409.JPGP1030417.JPGP1030420.JPG
                                                          Reply  Wed Aug 7 18:53:20 2013, Erica, DailyProgress, fiber optic, noise budget, Matlab notes. noise_budget.PNGP1030427.JPG
                                                             Reply  Tue Aug 13 12:39:36 2013, Erica, DailyProgress, fiber optic, rewrote calculations for converting from voltage noise to frequency noise P1030458.JPGP1030459.JPGP1030460.JPG
                                                       Reply  Tue Aug 13 12:28:20 2013, Erica, Notes, Electronics Equipment, new AD 590 circuit and its noise calculation, beam alignment P1030461.JPGP1030454.JPGP1030456.JPGP1030457.JPGAD590circuit2.PNG
                                                          Reply  Fri Aug 16 10:35:44 2013, Erica, Notes, Electronics Equipment, AD590 msrmt, conversion to freq noise 
                   Reply  Tue Jul 30 16:19:32 2013, Erica, Notes, fiber optic, setup for beam recombination new_setup.PNGbeam_recombination2.PNG
                   Reply  Mon Aug 5 12:21:00 2013, Erica, Notes, fiber optic, calculation: phase change for fiber 130805-121449.jpg
    Reply  Tue Jul 30 15:48:47 2013, Erica, DailyProgress, fiber optic, noise for GYRO 
Message ID: 1279     Entry time: Mon Aug 5 12:21:00 2013     In reply to: 1241
Author: Erica 
Type: Notes 
Category: fiber optic 
Subject: calculation: phase change for fiber 


I'm not sure of the exact material of the fiber and therefore its index of refraction and coefficient of thermal expansion, so I'll have to email Thorlabs.

Right now I have
n = 1.5
alpha = 10^-6 /K
lambda = 1064nm
L = 60m

to give a deltaT of about 10 mK for the temperature changed needed to change the length of the fiber by one wavelength, or for the phase to change by 2pi.
Attachment 1: 130805-121449.jpg  169 kB  Uploaded Mon Aug 5 13:22:30 2013  | Show | Show all
ELOG V3.1.3-