I ran another Comsol simulation with a simplified version of the PMC spacer. This time I put fixed constraints on two circular regions on the sides of the PMC near where it was clamped for the ringdown measurement. Comsol says the spacer has a mode where it twists about these clamp points, and the frequency of the mode is 270 Hz.

Attachment 1: pmc_clamp_twist_mode.jpg  24 kB  | Hide | Hide all
pmc_clamp_twist_mode.jpg