Entry  Wed Feb 27 10:16:09 2013, koji, tara, DailyProgress, Vacuum, opening vac chamber 
    Reply  Sun Mar 3 22:08:26 2013, tara, DailyProgress, Vacuum, opening vac chamber IMG_2255.JPGIMG_2258.JPGheater.pngdownload.jpg
       Reply  Wed Mar 6 12:48:50 2013, tara, DailyProgress, Vacuum, thermal shield + peek supports are baked photo(13).JPG
       Reply  Wed Mar 6 21:56:12 2013, tara, DailyProgress, Vacuum, note on feedthrough 
Message ID: 1108     Entry time: Sun Mar 3 22:08:26 2013     In reply to: 1106     Reply to this: 1109   1111
Author: tara 
Type: DailyProgress 
Category: Vacuum 
Subject: opening vac chamber 

 I found all necessary parts for the heater (crimp connectors, heating wire). I'll bake all parts once all the wiring is ready

 

 IMG_2255.JPGIMG_2258.JPG

fig1: left Dsub connector for the cable, Right, heater(yellowish wire around the tube) is connected to wiring cable with crimp connectors.

download.jpg

fig2: crimp connector( vacuum compatible material). I need to borrow the suitable crimp tool from Down, see PSL:775

heater.png

fig3: above, previous wiring (one heater,3 sensors), below current wiring (two heaters, two sensors)