40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
PSL |
Not logged in |
 |
|
Mon Nov 12 22:56:10 2012, tara, Notes, NoiseBudget, Thermoelastic noise in spacer and substrate
|
Tue Nov 13 01:56:24 2012, tara, Notes, NoiseBudget, Thermoelastic noise in spacer and substrate
|
Wed Nov 14 00:25:48 2012, tara, Notes, NoiseBudget, ฺBrownian noise in spacer and substrate
|
Wed Nov 14 19:46:47 2012, tara, Notes, NoiseBudget, Thermoelastic noise in spacer and substrate 
|
Tue Nov 20 11:50:29 2012, rana, Notes, NoiseBudget, Thermoelastic noise in spacer and substrate
|
Wed Nov 21 20:16:55 2012, rana, Notes, NoiseBudget, Thermoelastic noise in spacer and substrate
|
Mon Nov 26 15:36:46 2012, rana, Notes, NoiseBudget, Thermoelastic noise in spacer and substrate
|
Tue Nov 27 05:30:03 2012, rana, Notes, NoiseBudget, Thermoelastic noise in spacer and substrate
|
Tue Nov 27 05:38:01 2012, tara, Notes, NoiseBudget, Thermoelastic noise in spacer and substrate 
|
|
Message ID: 1081
Entry time: Mon Nov 26 15:36:46 2012
In reply to: 1080
Reply to this: 1082
|
Author: |
rana |
Type: |
Notes |
Category: |
NoiseBudget |
Subject: |
Thermoelastic noise in spacer and substrate |
|
|
If the Cerdonio paper is correct, then just use those equations instead of the Thorne ones. |