Entry  Mon Sep 17 19:06:36 2012, tara, Notes, PMC, stainless steel pmc 
    Reply  Mon Sep 24 16:41:19 2012, tara, Notes, PMC, stainless steel pmc pzt_snap.png
       Reply  Thu Nov 15 00:33:01 2012, tara, Notes, PMC, stainless steel pmc 
          Reply  Thu Nov 15 18:59:17 2012, tara, Notes, PMC, stainless steel pmc IMG_1982.jpg
Message ID: 1078     Entry time: Thu Nov 15 18:59:17 2012     In reply to: 1077
Author: tara 
Type: Notes 
Category: PMC 
Subject: stainless steel pmc 

The PMC round trip is ~ 0.32m. The end mirror has ROC = 1.0m. The spotsize is 384 micron.  The end mirror has radius ~2.5 mm. The clipping loss will be ~ 1*10^-43 on the curve mirror, and much smaller at the flat mirrors. The number seems very small but I think it is correct.

 This is just a simple integration for power of the beam P(a) where a = radius of the mirror (2.5mm). The total loss on all three mirrors per one trip is definitely way below 1ppm.

[add calculation]IMG_1982.jpg