40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
PSL |
Not logged in |
 |
|
Wed Jun 13 19:00:26 2012, Sarah, DailyProgress, Laser, Transfer Functions 12x
|
Fri Jun 22 22:34:28 2012, tara, DailyProgress, NoiseBudget, RIN coupling to Frequency noise
|
Wed Jun 27 18:51:56 2012, Sarah, DailyProgress, Laser, Transfer Functions    
|
Fri Jul 6 18:59:49 2012, tara, DailyProgress, Laser, Transfer Functions  
|
Tue Jul 10 02:55:37 2012, tara, DailyProgress, Laser, Transfer Functions
|
Mon Jul 16 19:08:34 2012, tara, DailyProgress, NoiseBudget, Transfer Functions (RIN to Frequency noise via photothermal)
|
Tue Jul 17 19:05:32 2012, tara, DailyProgress, NoiseBudget, Transfer Functions (RIN to Frequency noise via photothermal) 7x
|
Tue Jul 24 17:02:35 2012, Sarah, DailyProgress, NoiseBudget, Transfer Functions (RIN to Frequency noise via photothermal) 8x
|
Fri Aug 3 02:46:15 2012, tara, DailyProgress, NoiseBudget, Transfer Functions (RIN to Frequency noise via photothermal) 
|
Tue Aug 13 21:45:51 2013, tara, DailyProgress, NoiseBudget, Transfer Functions (RIN to Frequency noise via photothermal)   
|
Fri Aug 16 04:35:58 2013, tara, DailyProgress, NoiseBudget, Transfer Functions (RIN to Frequency noise via photothermal) 
|
Thu Aug 22 13:36:19 2013, tara, DailyProgress, NoiseBudget, Transfer Functions (RIN to Frequency noise via photothermal) 
|
Wed Jul 11 11:13:38 2012, Sarah, DailyProgress, Laser, Transfer Functions 7x
|
Sun Jul 15 23:20:32 2012, tara, DailyProgress, NoiseBudget, Transfer Functions (power fluctuation to Frequency noise via photothermal effect) 
|
Thu Jul 19 03:01:26 2012, tara, DailyProgress, NoiseBudget, Transfer Functions (power fluctuation to Frequency noise via photothermal effect) 
|
Thu Jul 19 23:56:45 2012, rana, DailyProgress, NoiseBudget, Transfer Functions (power fluctuation to Frequency noise via photothermal effect)
|
Fri Jul 20 01:32:45 2012, tara, DailyProgress, NoiseBudget, Transfer Functions (power fluctuation to Frequency noise via photothermal effect)
|
|
Message ID: 1025
Entry time: Thu Jul 19 23:56:45 2012
In reply to: 1023
Reply to this: 1027
|
Author: |
rana |
Type: |
DailyProgress |
Category: |
NoiseBudget |
Subject: |
Transfer Functions (power fluctuation to Frequency noise via photothermal effect) |
|
|
Does the coating term include the thermo-optic cancellation between thermo-refractive and thermo-elastic? I think you have to use the Evans/Ballmer paper for that (i.e. the GWINC code that I sent you before).
I am surprised if we can use these other papers without modification since the boundary conditions of our optic are fixed. The edge of the mirror doesn't move since its contacted to the spacer. How do you account for that? |