191
|
Wed Nov 16 09:35:59 2016 |
Gabriele | General | Measurements | S1600477 |
2016-11-16
- 9:34am in chamber, balanced
- 9:35am, roughing pump on
- 9:46am, turbo pump on
- Excitations:
-
Quiet time before excitation: 1163360707
Excitation (1100 Hz) at 1163360739 (60 s)
Excitation (broad band) at 1163360801 (60 s)
Quiet time after excitation: 1163360863
-
Quiet time before excitation: 1163368093
Excitation (1100 Hz) at 1163368125 (60 s)
Excitation (broad band) at 1163368187 (60 s)
Quiet time after excitation: 1163368249
-
3:31pm, pumps off
Results
2016-11-16 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1114.2 2.3007e+07 2.2987e+07 2.3027e+07
1133.4 2.2807e+06 2.2763e+06 2.2851e+06
2556.5 8.4325e+06 8.2252e+06 8.6504e+06
4452.8 8.8612e+06 8.8539e+06 8.8684e+06
4516.8 2.6142e+05 2.6001e+05 2.6284e+05
6792.4 6.6102e+06 6.6082e+06 6.6123e+06
6819.1 1.1027e+07 1.1024e+07 1.1031e+07
6864.1 1.9002e+06 1.8925e+06 1.9080e+06
9565.8 4.6820e+06 4.6648e+06 4.6993e+06
10275.1 1.5716e+07 1.5709e+07 1.5723e+07
12763.8 4.3417e+06 4.3388e+06 4.3447e+06
12886.1 6.6216e+05 6.5444e+05 6.7006e+05
14262.2 1.2383e+07 1.2361e+07 1.2405e+07
16179.4 5.6376e+06 5.6260e+06 5.6492e+06
16200.8 1.4003e+07 1.3963e+07 1.4043e+07
16388.5 4.0876e+06 4.0841e+06 4.0911e+06
17292.4 2.4283e+06 2.3986e+06 2.4587e+06
18752.8 1.3368e+07 1.3331e+07 1.3405e+07
18921.3 1.1843e+06 1.1815e+06 1.1871e+06
23710.2 1.1569e+07 1.1554e+07 1.1584e+07
23997.7 1.1157e+06 1.1157e+06 1.1158e+06
24816.8 2.5474e+06 2.5335e+06 2.5615e+06
25111.0 7.5175e+06 7.2921e+06 7.7572e+06
27302.7 1.4825e+07 1.4792e+07 1.4858e+07
29047.5 7.2879e+06 7.2272e+06 7.3495e+06
29140.0 4.9904e+06 4.9903e+06 4.9904e+06
29261.0 5.6779e+06 5.6778e+06 5.6779e+06
29673.0 4.5825e+05 4.5824e+05 4.5825e+05
29707.5 3.0382e+06 3.0381e+06 3.0382e+06
31013.6 8.4799e+05 8.4798e+05 8.4800e+05
31038.5 2.4742e+06 2.4742e+06 2.4742e+06
31914.0 6.6181e+06 6.4402e+06 6.8060e+06
2016-11-16 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1114.0 2.2032e+07 2.2016e+07 2.2049e+07
1133.4 1.9600e+06 1.9526e+06 1.9676e+06
2556.4 8.2944e+06 8.2588e+06 8.3304e+06
4452.9 8.1942e+06 8.1921e+06 8.1962e+06
4516.9 2.7235e+05 2.6914e+05 2.7564e+05
6792.4 6.0530e+06 6.0514e+06 6.0545e+06
6819.2 1.0600e+07 1.0597e+07 1.0602e+07
6864.1 1.8208e+06 1.8175e+06 1.8241e+06
9565.9 4.2971e+06 4.2755e+06 4.3189e+06
10275.1 1.4597e+07 1.4574e+07 1.4621e+07
12763.8 3.9316e+06 3.9287e+06 3.9344e+06
12886.2 6.4555e+05 6.3907e+05 6.5217e+05
14262.3 1.1328e+07 1.1324e+07 1.1331e+07
16179.5 5.2117e+06 5.1197e+06 5.3072e+06
16201.0 1.3620e+07 1.3572e+07 1.3668e+07
16388.6 3.7046e+06 3.6996e+06 3.7097e+06
17292.3 2.2071e+06 2.2070e+06 2.2072e+06
18921.6 1.2022e+06 1.1964e+06 1.2080e+06
21494.3 8.4330e+06 8.4082e+06 8.4580e+06
23710.4 1.0625e+07 1.0605e+07 1.0645e+07
23997.5 1.0698e+06 1.0697e+06 1.0698e+06
24817.0 2.3920e+06 2.3880e+06 2.3961e+06
25111.0 7.3811e+06 7.1248e+06 7.6564e+06
27302.9 1.3847e+07 1.3819e+07 1.3874e+07
29047.9 6.7327e+06 6.6911e+06 6.7749e+06
29673.0 4.4653e+05 4.4652e+05 4.4654e+05
29707.5 2.7395e+06 2.7224e+06 2.7569e+06
|
193
|
Wed Nov 16 15:57:21 2016 |
Gabriele | General | Measurements | S1600481 |
2016-11-16
- 3:56pm, in chamber, balanced
- 3:57pm, roughing pump on
- 4:07pm, turbo pump on
- Excitations:
-
Quiet time before excitation: 1163383462
Excitation (1100 Hz) at 1163383494 (60 s)
Excitation (broad band) at 1163383556 (60 s)
Quiet time after excitation: 1163383618
-
Quiet time before excitation: 1163394448
Excitation (1100 Hz) at 1163394480 (60 s)
Excitation (broad band) at 1163394542 (60 s)
Quiet time after excitation: 1163394604
-
Quiet time before excitation: 1163405434
xcitation (1100 Hz) at 1163405466 (60 s)
Excitation (broad band) at 1163405528 (60 s)
Quiet time after excitation: 1163405590
2016-11-17
Results
2016-11-16 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1094.3 1.2707e+07 1.2695e+07 1.2720e+07
2510.4 6.6163e+06 6.5897e+06 6.6431e+06
2548.6 1.1938e+05 1.1913e+05 1.1964e+05
4373.1 4.5232e+06 4.5188e+06 4.5275e+06
4435.8 2.3382e+05 2.3366e+05 2.3398e+05
6671.1 3.5757e+06 3.5748e+06 3.5767e+06
6697.5 1.8817e+07 1.8807e+07 1.8827e+07
6744.3 2.8118e+06 2.7759e+06 2.8485e+06
9395.6 2.2865e+06 2.2775e+06 2.2955e+06
10093.3 1.1448e+06 1.1445e+06 1.1452e+06
10240.0 2.0555e+06 2.0452e+06 2.0660e+06
11475.6 8.4917e+04 8.4913e+04 8.4921e+04
12537.1 2.2927e+06 2.2865e+06 2.2989e+06
15891.2 2.2520e+06 2.2469e+06 2.2572e+06
15914.6 7.8120e+06 7.8077e+06 7.8163e+06
16099.4 1.7394e+06 1.7372e+06 1.7415e+06
18426.5 8.3448e+05 8.2560e+05 8.4355e+05
21118.1 7.2440e+06 7.2347e+06 7.2532e+06
24381.7 1.0371e+06 1.0342e+06 1.0400e+06
24699.4 2.2364e+06 2.2168e+06 2.2563e+06
25794.0 5.1477e+06 5.0369e+06 5.2635e+06
26149.5 1.0102e+06 1.0102e+06 1.0102e+06
26830.0 1.0373e+07 1.0152e+07 1.0604e+07
28636.6 3.6000e+06 3.5828e+06 3.6174e+06
28745.9 1.7322e+07 1.7311e+07 1.7334e+07
29887.3 1.1030e+07 1.0956e+07 1.1105e+07
30842.6 2.4718e+06 2.4380e+06 2.5066e+06
31616.4 7.0754e+05 7.0753e+05 7.0755e+05
31640.4 1.9543e+06 1.9543e+06 1.9544e+06
32236.4 2.9076e+06 2.8843e+06 2.9313e+06
2016-11-16 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1094.0 1.1214e+07 1.1205e+07 1.1222e+07
2510.4 5.5745e+06 5.5710e+06 5.5780e+06
2548.5 1.3663e+05 1.3573e+05 1.3755e+05
4373.0 3.7426e+06 3.7368e+06 3.7484e+06
4435.8 2.3376e+05 2.3329e+05 2.3423e+05
6671.1 2.9264e+06 2.9246e+06 2.9282e+06
6697.5 1.6992e+07 1.6933e+07 1.7052e+07
6744.2 2.3626e+06 2.3012e+06 2.4273e+06
9395.5 2.0654e+06 2.0480e+06 2.0831e+06
10093.2 1.0860e+06 1.0850e+06 1.0870e+06
10239.9 2.0757e+06 2.0666e+06 2.0849e+06
11475.6 8.7886e+04 8.7883e+04 8.7890e+04
12537.0 1.8327e+06 1.8228e+06 1.8426e+06
14012.0 5.2022e+06 5.1550e+06 5.2502e+06
15891.1 2.1796e+06 2.1738e+06 2.1855e+06
15914.4 9.3495e+06 9.3457e+06 9.3534e+06
16099.4 1.6351e+06 1.6122e+06 1.6588e+06
21118.0 7.0081e+06 6.9894e+06 7.0268e+06
24381.5 9.2600e+05 9.1906e+05 9.3305e+05
24700.0 2.0943e+06 2.0943e+06 2.0943e+06
26830.0 9.4362e+06 9.3340e+06 9.5407e+06
28544.3 3.8658e+06 3.8010e+06 3.9328e+06
28636.3 3.0021e+06 2.9410e+06 3.0657e+06
28745.5 1.6500e+07 1.6430e+07 1.6571e+07
29887.7 1.0548e+07 1.0517e+07 1.0579e+07
30843.0 2.1072e+06 2.0887e+06 2.1260e+06
31616.6 6.3649e+05 6.3647e+05 6.3650e+05
31640.6 1.5725e+06 1.5725e+06 1.5726e+06
32236.5 2.8396e+06 2.8396e+06 2.8397e+06
2016-11-16 C
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1094.0 1.0880e+07 1.0873e+07 1.0886e+07
2188.0 1.0548e+07 1.0120e+07 1.1012e+07
2510.3 5.5686e+06 5.5662e+06 5.5709e+06
2548.5 1.4731e+05 1.4406e+05 1.5070e+05
3949.0 1.7959e+04 1.7957e+04 1.7961e+04
4373.0 3.7404e+06 3.7350e+06 3.7459e+06
4435.7 2.3448e+05 2.3401e+05 2.3495e+05
6671.0 2.9331e+06 2.9319e+06 2.9343e+06
6697.5 1.6931e+07 1.6927e+07 1.6936e+07
6744.3 2.3960e+06 2.3820e+06 2.4101e+06
9395.5 2.1238e+06 2.1073e+06 2.1405e+06
10093.2 1.0588e+06 1.0583e+06 1.0592e+06
10239.8 2.2057e+06 2.1138e+06 2.3059e+06
11310.5 8.0028e+04 8.0025e+04 8.0032e+04
12537.0 1.9366e+06 1.8964e+06 1.9785e+06
14012.0 4.0122e+06 3.9559e+06 4.0700e+06
15891.3 2.2887e+06 2.2460e+06 2.3331e+06
15914.3 1.1138e+07 1.1136e+07 1.1140e+07
16099.3 1.7494e+06 1.7465e+06 1.7523e+06
21117.9 7.0869e+06 7.0802e+06 7.0935e+06
24381.4 9.2827e+05 9.2825e+05 9.2828e+05
24700.0 1.9847e+06 1.9846e+06 1.9847e+06
26829.7 9.1098e+06 8.9846e+06 9.2385e+06
28544.0 3.9652e+06 3.9652e+06 3.9653e+06
28746.0 1.5590e+07 1.5326e+07 1.5863e+07
29887.6 1.0657e+07 1.0505e+07 1.0813e+07
30843.4 2.0614e+06 2.0613e+06 2.0614e+06
32236.6 2.9582e+06 2.9062e+06 3.0122e+06
|
194
|
Thu Nov 17 09:35:51 2016 |
Gabriele | General | Measurements | S1600483 |
2016-11-17
- 9:24am in chamber, balanced
- 9:35am roughing pump on
- 9:46am, turbo pump on
- Excitations
-
Quiet time before excitation: 1163451715
Excitation (1100 Hz) at 1163451747 (60 s)
Excitation (broad band) at 1163451809 (60 s)
Quiet time after excitation: 1163451871
-
Quiet time before excitation: 1163459101
Excitation (1100 Hz) at 1163459133 (60 s)
Excitation (broad band) at 1163459195 (60 s)
Quiet time after excitation: 1163459257
- 5:12pm, pumps off
Results
2016-11-17 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1110.6 5.2498e+06 5.2441e+06 5.2555e+06
1129.0 1.9008e+06 1.8988e+06 1.9028e+06
2546.3 2.5599e+06 2.5581e+06 2.5616e+06
2583.7 6.4098e+05 6.4022e+05 6.4174e+05
3600.5 1.4764e+06 1.4762e+06 1.4766e+06
4375.0 1.7752e+06 1.7646e+06 1.7859e+06
4433.3 1.7154e+06 1.7143e+06 1.7164e+06
4494.9 2.5500e+05 2.5476e+05 2.5523e+05
5266.0 2.1175e+06 2.1173e+06 2.1177e+06
6760.5 1.4261e+06 1.4249e+06 1.4273e+06
6778.3 7.4161e+06 7.3905e+06 7.4418e+06
6833.2 1.0592e+06 1.0586e+06 1.0597e+06
6893.1 5.8100e+04 5.8096e+04 5.8104e+04
9460.5 1.3366e+06 1.3366e+06 1.3367e+06
9518.8 1.2075e+06 1.2066e+06 1.2084e+06
9577.0 1.4045e+06 1.4044e+06 1.4046e+06
10361.5 9.2547e+05 9.1119e+05 9.4021e+05
12698.7 9.8384e+05 9.8240e+05 9.8528e+05
14185.0 3.7722e+06 3.6989e+06 3.8485e+06
16093.2 1.3155e+06 1.3120e+06 1.3190e+06
16105.8 4.9502e+06 4.8453e+06 5.0597e+06
16300.5 8.9537e+05 8.9535e+05 8.9540e+05
20280.0 4.6430e+05 4.6429e+05 4.6431e+05
21990.6 2.5384e+06 2.5383e+06 2.5384e+06
23585.0 2.3607e+06 2.3607e+06 2.3608e+06
24661.0 1.9657e+05 1.9657e+05 1.9658e+05
25335.0 2.1695e+06 2.1694e+06 2.1695e+06
25641.0 3.7421e+05 3.7420e+05 3.7422e+05
27148.6 5.0750e+06 5.0749e+06 5.0751e+06
28901.1 1.5001e+06 1.5001e+06 1.5002e+06
29471.0 6.6842e+06 6.6841e+06 6.6843e+06
29536.0 5.1655e+05 5.1655e+05 5.1656e+05
31209.5 6.6357e+05 6.6356e+05 6.6358e+05
31845.0 1.1993e+06 1.1992e+06 1.1993e+06
2016-11-17 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1110.5 5.1474e+06 5.1428e+06 5.1520e+06
1129.0 1.7959e+06 1.7941e+06 1.7977e+06
2487.7 2.2593e+06 2.2231e+06 2.2966e+06
2546.1 2.4932e+06 2.4917e+06 2.4948e+06
2583.6 6.7688e+05 6.7638e+05 6.7738e+05
2604.4 2.3700e+06 2.3388e+06 2.4020e+06
4374.7 1.4494e+06 1.4112e+06 1.4898e+06
4433.2 1.6734e+06 1.6723e+06 1.6745e+06
4494.8 2.5845e+05 2.5822e+05 2.5869e+05
6760.3 1.3915e+06 1.3904e+06 1.3925e+06
6778.0 7.2310e+06 7.2210e+06 7.2410e+06
6833.0 1.0473e+06 1.0469e+06 1.0478e+06
6893.0 5.8318e+04 5.8314e+04 5.8322e+04
9460.3 1.0963e+06 1.0962e+06 1.0963e+06
9518.4 1.1841e+06 1.1833e+06 1.1849e+06
9576.6 1.1146e+06 1.1145e+06 1.1146e+06
10217.0 8.1285e+05 8.1281e+05 8.1289e+05
10361.1 9.0908e+05 8.9989e+05 9.1846e+05
12698.2 9.8778e+05 9.7292e+05 1.0031e+06
14184.5 3.8766e+06 3.8765e+06 3.8767e+06
16092.6 1.2675e+06 1.2645e+06 1.2704e+06
16105.1 4.7982e+06 4.6884e+06 4.9132e+06
16299.9 8.4326e+05 8.4043e+05 8.4612e+05
20241.0 4.9087e+05 4.9086e+05 4.9088e+05
20279.4 4.9025e+05 4.9023e+05 4.9026e+05
21368.0 2.6590e+06 2.6589e+06 2.6591e+06
21643.5 3.3917e+05 3.3916e+05 3.3918e+05
23584.4 2.1538e+06 2.1538e+06 2.1539e+06
23734.6 3.5223e+05 3.5223e+05 3.5224e+05
27147.4 4.9544e+06 4.8874e+06 5.0233e+06
28899.9 1.4530e+06 1.4374e+06 1.4690e+06
29080.0 8.8363e+06 8.8362e+06 8.8365e+06
29522.4 4.6567e+05 4.6567e+05 4.6568e+05
30440.3 1.2458e+06 1.2457e+06 1.2458e+06
31211.0 6.6406e+05 6.6405e+05 6.6407e+05
|
197
|
Thu Nov 17 17:54:13 2016 |
Gabriele | General | Measurements | S1600439 after CO2 laser polishing |
Previous measurments
- post annealing 144
- pre annealing 137
2016-11-17
- 5:52pm, in chamber, balanced
- 5:53pm, roughing pump on
- 6:04pm, turbo pump on
- 6:05pm, air filters off
- Excitations:
-
Quiet time before excitation: 1163480205
Excitation (1100 Hz) at 1163480237 (60 s)
Excitation (broad band) at 1163480299 (60 s)
Quiet time after excitation: 1163480361
-
Quiet time before excitation: 1163494791
Excitation (1100 Hz) at 1163494824 (60 s)
Excitation (broad band) at 1163494886 (60 s)
Quiet time after excitation: 1163494948
-
Quiet time before excitation: 1163509378
Excitation (1100 Hz) at 1163509411 (60 s)
Excitation (broad band) at 1163509473 (60 s)
Quiet time after excitation: 1163509535
2016-11-18
Results
2016-11-17 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1127.6 3.7205e+07 3.7099e+07 3.7311e+07
1149.8 5.7351e+05 5.7170e+05 5.7532e+05
2516.5 1.1828e+07 1.1490e+07 1.2186e+07
2574.8 1.3400e+07 1.3395e+07 1.3404e+07
2633.3 1.2628e+07 1.2459e+07 1.2802e+07
4474.7 2.4553e+07 2.4547e+07 2.4559e+07
4544.8 1.8667e+05 1.8641e+05 1.8693e+05
6759.0 1.8704e+07 1.8468e+07 1.8946e+07
6789.3 2.5840e+07 2.5830e+07 2.5850e+07
6817.2 1.9911e+07 1.9909e+07 1.9914e+07
6875.5 1.9155e+07 1.8915e+07 1.9401e+07
6896.6 3.0284e+06 3.0201e+06 3.0366e+06
9593.1 1.3325e+07 1.3319e+07 1.3332e+07
10242.1 1.3837e+07 1.3830e+07 1.3844e+07
10407.9 1.8996e+06 1.8632e+06 1.9374e+06
12793.6 1.1109e+07 1.1108e+07 1.1110e+07
12852.0 1.0545e+07 9.7561e+06 1.1473e+07
16145.3 3.0830e+06 3.0717e+06 3.0943e+06
16157.3 3.1104e+06 3.1087e+06 3.1120e+06
16421.2 9.5753e+05 9.5258e+05 9.6254e+05
18715.3 8.1385e+06 8.1309e+06 8.1461e+06
20416.5 2.5193e+05 2.5192e+05 2.5193e+05
21438.5 1.0088e+07 1.0036e+07 1.0141e+07
21741.0 2.0006e+05 2.0006e+05 2.0007e+05
23667.3 1.4606e+07 1.4548e+07 1.4665e+07
23826.4 2.5707e+05 2.5707e+05 2.5708e+05
23986.1 6.6046e+06 6.5724e+06 6.6371e+06
24849.9 3.1250e+06 3.1187e+06 3.1313e+06
25164.4 8.5725e+06 8.4512e+06 8.6973e+06
25462.9 4.0887e+06 4.0761e+06 4.1014e+06
25483.9 4.1145e+06 4.0637e+06 4.1666e+06
27245.8 1.4814e+07 1.4743e+07 1.4884e+07
28991.0 1.3488e+07 1.3478e+07 1.3497e+07
29095.2 5.2186e+06 5.2043e+06 5.2330e+06
29167.4 1.6466e+07 1.6231e+07 1.6707e+07
29749.1 5.0360e+05 5.0359e+05 5.0361e+05
30206.6 4.2957e+06 4.2020e+06 4.3937e+06
31045.1 3.1095e+06 3.1029e+06 3.1161e+06
31088.9 9.3908e+06 9.3757e+06 9.4060e+06
31710.0 2.4880e+06 2.4880e+06 2.4880e+06
31969.7 1.1411e+07 1.1372e+07 1.1451e+07
2016-11-17 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1127.9 3.7152e+07 3.7077e+07 3.7227e+07
2574.7 1.4429e+07 1.4424e+07 1.4434e+07
2633.0 1.6022e+07 1.4847e+07 1.7399e+07
4474.6 2.4432e+07 2.4419e+07 2.4445e+07
4544.7 1.9919e+05 1.9877e+05 1.9961e+05
6789.2 2.5907e+07 2.5888e+07 2.5927e+07
6817.0 1.9832e+07 1.9829e+07 1.9835e+07
6896.5 2.9655e+06 2.9546e+06 2.9765e+06
9593.0 1.3275e+07 1.3236e+07 1.3313e+07
10242.0 1.3491e+07 1.3479e+07 1.3502e+07
10407.7 1.8960e+06 1.8810e+06 1.9113e+06
12793.4 1.1592e+07 1.1590e+07 1.1594e+07
16144.7 4.6655e+06 4.5884e+06 4.7452e+06
16157.0 3.1237e+06 3.1216e+06 3.1258e+06
16420.9 1.3524e+06 1.3493e+06 1.3555e+06
17291.0 3.3682e+06 3.2925e+06 3.4475e+06
18714.9 8.1669e+06 8.1601e+06 8.1737e+06
20351.4 9.4653e+05 9.4188e+05 9.5123e+05
20416.2 1.1000e+06 1.0988e+06 1.1012e+06
21438.1 8.4404e+06 8.3969e+06 8.4845e+06
23666.9 1.4674e+07 1.4646e+07 1.4703e+07
23825.7 2.6272e+05 2.6271e+05 2.6272e+05
23987.0 5.6799e+06 5.6251e+06 5.7359e+06
24849.4 4.3992e+06 4.3821e+06 4.4165e+06
25165.0 9.0003e+06 8.8068e+06 9.2025e+06
25463.6 4.1230e+06 4.1124e+06 4.1336e+06
25484.8 4.1183e+06 4.0858e+06 4.1513e+06
28990.5 1.3604e+07 1.3550e+07 1.3658e+07
29094.6 5.9875e+06 5.9654e+06 6.0097e+06
29167.0 1.6703e+07 1.6387e+07 1.7032e+07
29748.5 5.6280e+05 5.6279e+05 5.6281e+05
30207.5 4.1567e+06 4.0927e+06 4.2228e+06
31045.8 3.2297e+06 3.2207e+06 3.2388e+06
31089.5 9.4448e+06 9.4187e+06 9.4709e+06
31711.0 2.4572e+06 2.4571e+06 2.4572e+06
31970.4 1.1648e+07 1.1605e+07 1.1691e+07
|
199
|
Fri Nov 18 09:27:26 2016 |
Gabriele | General | Measurements | CO2 polishing improves the Q !! |
The plot below shows that the Q values of S1600439 improved a lot after the CO2 laser polishing. About 15 modes have Q above 10e6. The first mode at 1kHz has a Q of 37e6, the highest ever measured so far!

Here's a comparison of the Q values of this sample before annealing, after annealing and after CO2 polishing.

|
200
|
Fri Nov 18 11:39:59 2016 |
Gabriele | General | Measurements | S1600480 |
Note: marked at "D?" by Alena
2016-11-18
- 11:38am, in chamber, balanced
- 11:39am, roughing pump on
- 11:51am, turbo pump on
- 3:54pm, excitation (3kV), quiet time before 1163547289, quiet time after 1163548497
- Automated excitations:
-
Quiet time before excitation: 1163563312
Excitation (1100 Hz) at 1163563344 (60 s)
Excitation (broad band) at 1163563406 (60 s)
Quiet time after excitation: 1163563468
-
Quiet time before excitation: 1163577898
Excitation (1100 Hz) at 1163577931 (60 s)
Excitation (broad band) at 1163577993 (60 s)
Quiet time after excitation: 1163578055
-
Quiet time before excitation: 1163592485
Excitation (1100 Hz) at 1163592517 (60 s)
Excitation (broad band) at 1163592579 (60 s)
Quiet time after excitation: 1163592641
2016-11-20
Results
2016-11-18 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1104.1 1.0173e+07 1.0152e+07 1.0195e+07
1124.3 8.2131e+05 8.1929e+05 8.2333e+05
2532.6 5.0306e+06 5.0249e+06 5.0363e+06
2573.3 1.3847e+06 1.3808e+06 1.3886e+06
4411.2 2.8588e+06 2.8563e+06 2.8613e+06
4476.9 2.0843e+05 2.0731e+05 2.0956e+05
6729.4 2.6143e+06 2.6132e+06 2.6155e+06
6747.8 1.2395e+07 1.2374e+07 1.2417e+07
6806.2 2.1725e+06 2.1449e+06 2.2008e+06
6873.5 1.4735e+05 1.4563e+05 1.4911e+05
9478.1 2.0101e+06 2.0082e+06 2.0120e+06
10171.9 9.4754e+06 9.4682e+06 9.4827e+06
10325.5 2.9800e+06 2.9785e+06 2.9815e+06
12648.0 1.7468e+06 1.7413e+06 1.7524e+06
12773.7 5.3335e+05 5.2619e+05 5.4072e+05
14123.2 7.1655e+06 7.1632e+06 7.1678e+06
16018.0 2.2296e+06 2.2274e+06 2.2319e+06
16033.8 6.7662e+06 6.7549e+06 6.7775e+06
16242.7 1.5742e+06 1.5712e+06 1.5773e+06
17697.8 1.1028e+06 1.0837e+06 1.1227e+06
18281.0 1.5366e+06 1.5366e+06 1.5366e+06
18573.5 4.3588e+05 4.3587e+05 4.3589e+05
18745.4 3.4263e+05 3.4262e+05 3.4264e+05
20032.7 3.3234e+05 3.3233e+05 3.3235e+05
20150.9 1.1528e+06 1.1528e+06 1.1529e+06
20206.1 1.2661e+06 1.2631e+06 1.2691e+06
21282.5 1.0456e+07 1.0450e+07 1.0462e+07
21568.7 5.5263e+05 5.4626e+05 5.5915e+05
22166.5 2.8542e+06 2.8541e+06 2.8542e+06
23484.9 5.0281e+06 5.0189e+06 5.0374e+06
23636.0 4.3875e+05 4.3874e+05 4.3876e+05
24559.0 1.9874e+05 1.9873e+05 1.9874e+05
24598.4 1.3312e+06 1.2994e+06 1.3647e+06
25479.2 4.4672e+06 4.3821e+06 4.5558e+06
27041.0 4.9796e+06 4.9564e+06 5.0031e+06
28764.5 2.2975e+06 2.2895e+06 2.3055e+06
28862.1 2.7554e+06 2.7260e+06 2.7855e+06
29272.0 7.3791e+05 7.3790e+05 7.3792e+05
29453.0 3.7211e+05 3.7211e+05 3.7212e+05
29617.4 5.4367e+06 5.3598e+06 5.5159e+06
30529.7 1.9682e+06 1.9682e+06 1.9683e+06
31344.8 9.4048e+05 9.4047e+05 9.4050e+05
31970.0 4.2696e+06 4.2435e+06 4.2960e+06
32227.0 6.7855e+06 6.7854e+06 6.7856e+06
2016-11-18 B
 

% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1104.0 1.0297e+07 1.0284e+07 1.0311e+07
1124.4 1.1668e+06 1.1652e+06 1.1684e+06
2532.6 5.0152e+06 5.0134e+06 5.0170e+06
2573.3 1.4606e+06 1.4576e+06 1.4637e+06
4411.3 3.3395e+06 3.3382e+06 3.3409e+06
4477.1 2.0944e+05 2.0896e+05 2.0991e+05
6729.7 2.6053e+06 2.6046e+06 2.6061e+06
6748.2 1.2388e+07 1.2379e+07 1.2398e+07
6806.5 2.1415e+06 2.1369e+06 2.1461e+06
6873.8 1.4706e+05 1.4619e+05 1.4794e+05
9478.4 2.0036e+06 2.0025e+06 2.0046e+06
10172.5 9.4094e+06 9.3186e+06 9.5020e+06
10326.0 2.9820e+06 2.9804e+06 2.9836e+06
12648.4 1.7268e+06 1.7241e+06 1.7295e+06
12774.1 4.9106e+05 4.7983e+05 5.0283e+05
14123.6 3.1322e+06 3.1310e+06 3.1335e+06
16018.6 2.2761e+06 2.2742e+06 2.2780e+06
16034.5 8.0306e+06 8.0250e+06 8.0361e+06
16243.3 1.5954e+06 1.5909e+06 1.5998e+06
18574.2 3.3307e+06 3.3155e+06 3.3460e+06
18746.1 9.1765e+05 9.1638e+05 9.1892e+05
20151.5 1.0945e+06 1.0635e+06 1.1273e+06
20206.9 1.2644e+06 1.2579e+06 1.2709e+06
21283.4 1.0704e+07 1.0692e+07 1.0717e+07
21569.6 5.5770e+05 5.5558e+05 5.5983e+05
23485.8 5.0910e+06 5.0796e+06 5.1023e+06
24599.2 1.2773e+06 1.2665e+06 1.2883e+06
25477.5 4.3947e+06 4.3268e+06 4.4648e+06
25828.0 7.4575e+05 7.2022e+05 7.7315e+05
27042.2 4.9480e+06 4.9335e+06 4.9625e+06
28765.8 2.2507e+06 2.2298e+06 2.2721e+06
28863.2 2.7105e+06 2.6968e+06 2.7243e+06
28961.6 8.5083e+06 8.4642e+06 8.5529e+06
29615.6 5.4281e+06 5.2865e+06 5.5774e+06
30528.4 1.9676e+06 1.9223e+06 2.0150e+06
31343.4 9.0249e+05 8.8999e+05 9.1536e+05
31968.6 4.2914e+06 4.2817e+06 4.3012e+06
2016-11-18 C
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1104.1 1.0082e+07 1.0063e+07 1.0100e+07
1124.5 1.3397e+06 1.3366e+06 1.3427e+06
2532.8 4.9558e+06 4.9513e+06 4.9604e+06
2573.5 1.4059e+06 1.3996e+06 1.4122e+06
4411.6 3.1148e+06 3.1116e+06 3.1180e+06
4477.4 2.1088e+05 2.1055e+05 2.1121e+05
6730.2 2.5865e+06 2.5850e+06 2.5881e+06
6748.7 1.2747e+07 1.2486e+07 1.3019e+07
6807.0 2.1437e+06 2.1251e+06 2.1626e+06
6874.2 1.5494e+05 1.5375e+05 1.5614e+05
9479.1 2.0187e+06 1.9656e+06 2.0748e+06
10173.2 9.4877e+06 9.4764e+06 9.4990e+06
10326.7 3.0116e+06 3.0106e+06 3.0127e+06
12649.3 1.7115e+06 1.6986e+06 1.7247e+06
14124.9 9.1986e+05 9.1825e+05 9.2148e+05
16019.8 2.2901e+06 2.2890e+06 2.2913e+06
16035.7 8.1365e+06 8.1202e+06 8.1529e+06
16244.6 1.5627e+06 1.5520e+06 1.5735e+06
18575.7 5.0190e+06 5.0085e+06 5.0296e+06
18747.6 2.2873e+06 2.2850e+06 2.2896e+06
20153.0 1.1379e+06 1.1286e+06 1.1474e+06
20208.4 1.2843e+06 1.2797e+06 1.2891e+06
21285.1 1.0850e+07 1.0800e+07 1.0899e+07
23487.6 5.1931e+06 5.1699e+06 5.2165e+06
23638.5 4.6983e+05 4.5937e+05 4.8078e+05
24562.0 2.0605e+05 1.9793e+05 2.1488e+05
25474.4 4.3828e+06 4.2782e+06 4.4926e+06
27044.4 4.4216e+06 4.4140e+06 4.4293e+06
28767.9 2.2400e+06 2.2194e+06 2.2610e+06
28865.5 2.4306e+06 2.3822e+06 2.4810e+06
28963.9 8.4171e+06 8.3301e+06 8.5059e+06
29425.5 1.2180e+06 1.1936e+06 1.2434e+06
30525.7 1.9877e+06 1.9649e+06 2.0110e+06
31340.9 9.0879e+05 8.9734e+05 9.2053e+05
31965.9 4.3188e+06 4.3004e+06 4.3374e+06
32222.9 6.8476e+06 6.7375e+06 6.9614e+06
|
201
|
Fri Nov 18 15:48:09 2016 |
Gabriele | General | Measurements | Microscope inspection of CO2 polished samples |
S1600470
For reference, this sample has not been CO2 polished, but it has been annealed and measured. It has quite low Q values. Here are some images of the edges. The first two are taken with light from above. In the second one there some clear red residual, which is also visible as a coloration with the naked eye. The microroughness and some larger defect are well visible.
 
The following images instead are taken with light from below. The red residual is even more evident, and some traces probably due to the machining are clearly visible.
 
S1600479
This sample has been laser polished with a double pass (first at 0.5 mm/s, second at 0.25 mm/s). The first two images are taken with light from above: they are not very clear because of the specular reflection of the lamps. This already indicates that the surface is much smoother. Some defects (bubbles?) are visible close to the main surfaces.
 
The surface quality is more apparent in the following pictures, taken with light from below. The second one is taken where there is a chip in the main surface, and indeed one can see the shading due to the light distortion iduced by the chip. Also a cluster of "bubbles" is clearly visible there.
 
S1600462
This was our first polishing test. It is interesting because the laser tripped during the procedure, so we have a neat transition from the original surface to the polished one. First image taken with light from above, second with light from below
 
|
Attachment 9: S1600462_3.png
|
|
202
|
Sun Nov 20 14:40:14 2016 |
Gabriele | General | Measurements | S1600482 |
Note: marked as "scratched" by Alena
2016-11-20
- 2:38pm, in chamber, balanced
- 2:39pm roughing pump on
- 2:50pm, turbo pump on
- Excitations:
-
Quiet time before excitation: 1163731955
Excitation (1100 Hz) at 1163731988 (60 s)
Excitation (broad band) at 1163732051 (60 s)
Quiet time after excitation: 1163732113
-
Quiet time before excitation: 1163746543
Excitation (1100 Hz) at 1163746575 (60 s)
Excitation (broad band) at 1163746637 (60 s)
Quiet time after excitation: 1163746699
-
Quiet time before excitation: 1163761129
Excitation (1100 Hz) at 1163761161 (60 s)
Excitation (broad band) at 1163761223 (60 s)
Quiet time after excitation: 1163761285
2016-11-21
- ~8:50am Pumps off when the electricians switched off the power (to fix flooding in another lab).
Results
2016-11-20 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1105.6 1.3699e+07 1.3679e+07 1.3719e+07
1129.5 1.2592e+06 1.2582e+06 1.2602e+06
2536.9 6.9108e+06 6.9091e+06 6.9125e+06
2582.0 1.0950e+06 1.0945e+06 1.0954e+06
4419.5 4.6415e+06 4.6408e+06 4.6422e+06
6741.0 4.6109e+06 4.6085e+06 4.6133e+06
6751.5 7.3558e+06 7.3545e+06 7.3572e+06
6760.0 9.3303e+05 9.1696e+05 9.4966e+05
6817.9 8.8863e+05 8.8845e+05 8.8881e+05
6876.4 9.0884e+05 8.9493e+05 9.2320e+05
9501.3 2.1618e+06 2.1613e+06 2.1622e+06
10176.4 1.0854e+07 1.0851e+07 1.0857e+07
12682.4 2.2503e+06 2.2480e+06 2.2527e+06
14133.9 7.2804e+06 7.2779e+06 7.2829e+06
16033.5 5.5906e+06 5.5589e+06 5.6227e+06
16293.6 2.0220e+06 2.0213e+06 2.0226e+06
18591.1 5.6667e+06 5.6569e+06 5.6766e+06
20188.1 5.3541e+05 5.3539e+05 5.3542e+05
20260.5 1.2546e+06 1.2487e+06 1.2607e+06
21301.6 8.9899e+06 8.9852e+06 8.9945e+06
23507.9 6.7449e+06 6.7090e+06 6.7812e+06
23665.4 4.2237e+05 4.2236e+05 4.2237e+05
24674.0 1.7576e+06 1.7419e+06 1.7736e+06
27071.8 1.0639e+07 1.0601e+07 1.0679e+07
28778.0 4.4868e+06 4.4779e+06 4.4957e+06
28875.5 3.2816e+06 3.2506e+06 3.3131e+06
28971.4 1.3371e+07 1.3319e+07 1.3422e+07
29588.4 6.4932e+06 6.4563e+06 6.5304e+06
31309.6 1.3159e+06 1.3159e+06 1.3159e+06
32182.4 4.1484e+06 4.0890e+06 4.2095e+06
2016-11-20 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1106.0 1.3735e+07 1.3705e+07 1.3765e+07
1129.4 1.3461e+06 1.3447e+06 1.3475e+06
2536.9 6.9208e+06 6.9190e+06 6.9225e+06
2581.9 1.1022e+06 1.1018e+06 1.1027e+06
4419.5 4.6410e+06 4.6403e+06 4.6417e+06
6741.0 4.5896e+06 4.5529e+06 4.6269e+06
6751.5 7.3617e+06 7.3515e+06 7.3719e+06
6817.9 8.8718e+05 8.8685e+05 8.8752e+05
9501.3 2.0661e+06 2.0623e+06 2.0699e+06
10176.5 1.0802e+07 1.0799e+07 1.0806e+07
12682.5 2.2575e+06 2.2491e+06 2.2659e+06
14134.0 7.4453e+06 7.4405e+06 7.4502e+06
16032.3 3.4372e+06 3.4136e+06 3.4611e+06
16293.6 2.0186e+06 2.0172e+06 2.0200e+06
18591.1 5.5027e+06 5.4999e+06 5.5054e+06
20188.4 5.3252e+05 5.3251e+05 5.3254e+05
20260.5 1.2588e+06 1.2465e+06 1.2713e+06
21301.7 9.0170e+06 9.0118e+06 9.0222e+06
23507.9 6.6291e+06 6.6017e+06 6.6567e+06
23665.4 4.4613e+05 4.4612e+05 4.4614e+05
24220.0 1.9037e+06 1.9037e+06 1.9037e+06
24674.0 1.7636e+06 1.7466e+06 1.7809e+06
27071.8 1.0771e+07 1.0668e+07 1.0875e+07
28778.1 4.5042e+06 4.4886e+06 4.5200e+06
28875.5 3.3774e+06 3.3375e+06 3.4182e+06
28971.5 1.2966e+07 1.2933e+07 1.2999e+07
29588.4 6.3389e+06 6.2527e+06 6.4275e+06
31310.0 1.3706e+06 1.3706e+06 1.3706e+06
32182.1 4.6113e+06 4.5490e+06 4.6755e+06
|
Attachment 3: ringdowns.png
|
|
203
|
Mon Nov 21 11:05:51 2016 |
Gabriele | General | Measurements | S1600487 |
Note: not annealed
2016-11-21
- 11:04am in chamber, balanced
- 11:05am roughing pump on
- 11:15am turbo pump on
- 12:49pm, excitation (2kV, 60 s), quiet time before: 1163796504, quiet time after 1163796645
- 1:44pm, excitation (2kV, 60s), quiet time before 1163799861, quiet time after 1163799969
- 2:35pm pumps off
Sample has been laser polished by Alastair and Gabriele.
Results
2016-11-21 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1092.0 2.0996e+06 2.0980e+06 2.1013e+06
2505.5 3.7980e+05 3.7943e+05 3.8017e+05
2544.1 1.9755e+04 1.9274e+04 2.0261e+04
4364.5 8.9303e+05 8.9272e+05 8.9334e+05
4426.6 2.0585e+05 2.0551e+05 2.0619e+05
6658.1 7.3829e+05 7.3655e+05 7.4004e+05
6673.2 3.5144e+06 3.4646e+06 3.5657e+06
6729.6 7.3540e+05 7.3412e+05 7.3668e+05
6791.9 1.4926e+05 1.4783e+05 1.5072e+05
9378.0 6.2587e+05 6.2453e+05 6.2722e+05
10060.0 1.8195e+06 1.8128e+06 1.8263e+06
10206.0 8.1387e+05 8.0392e+05 8.2406e+05
12514.4 5.1323e+05 5.0504e+05 5.2168e+05
15851.5 7.7288e+05 7.7105e+05 7.7471e+05
16069.0 5.1586e+05 5.0878e+05 5.2313e+05
21045.5 3.0229e+06 3.0036e+06 3.0425e+06
28565.0 5.7365e+05 5.3858e+05 6.1362e+05
30008.1 3.8168e+06 3.7090e+06 3.9310e+06
32597.0 1.2310e+06 1.1514e+06 1.3224e+06
2016-11-21 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1092.1 2.1370e+06 2.1351e+06 2.1389e+06
1110.8 1.2884e+06 1.2787e+06 1.2982e+06
2505.6 4.6204e+05 4.5453e+05 4.6981e+05
4364.6 9.0907e+05 9.0847e+05 9.0967e+05
4426.5 2.1117e+05 2.0306e+05 2.1996e+05
6658.2 7.3579e+05 7.3277e+05 7.3883e+05
6673.3 3.4406e+06 3.4108e+06 3.4709e+06
6729.6 7.3685e+05 7.3540e+05 7.3830e+05
6791.7 1.4679e+05 1.3208e+05 1.6520e+05
9377.9 6.4036e+05 6.2873e+05 6.5242e+05
10059.9 1.7966e+06 1.7905e+06 1.8028e+06
12514.4 6.2867e+05 3.7657e+05 1.9017e+06
15851.4 7.7502e+05 7.7177e+05 7.7829e+05
16068.5 5.2815e+05 5.0732e+05 5.5076e+05
21045.5 3.1520e+06 3.0746e+06 3.2334e+06
30008.2 3.6847e+06 3.6042e+06 3.7689e+06
|
206
|
Mon Nov 21 16:37:01 2016 |
Gabriele | General | Measurements | S1600487 post polishing |
2016-11-21
- 4:34pm, in chamber, balanced
- 4:35pm, roughing pump on
- 4:45pm, turbo pump on
- Excitations
-
Quiet time before excitation: 1163826122
Excitation (1100 Hz) at 1163826154 (60 s)
Excitation (broad band) at 1163826216 (60 s)
Quiet time after excitation: 1163826278
-
Quiet time before excitation: 1163840708
Excitation (1100 Hz) at 1163840740 (60 s)
Excitation (broad band) at 1163840803 (60 s)
Quiet time after excitation: 1163840865
-
Quiet time before excitation: 1163855295
Excitation (1100 Hz) at 1163855328 (60 s)
Excitation (broad band) at 1163855391 (60 s)
Quiet time after excitation: 1163855453
2016-11-22
- Excitations
-
Quiet time before excitation: 1163873594
Excitation (1100 Hz) at 1163873626 (60 s)
Excitation (broad band) at 1163873688 (60 s)
Quiet time after excitation: 1163873750
-
Quiet time before excitation: 1163880980
Excitation (1100 Hz) at 1163881012 (60 s)
Excitation (broad band) at 1163881075 (60 s)
Quiet time after excitation: 1163881137
-
2:55pm pumps off
Results
2016-11-22 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1070.1 1.9388e+06 1.9315e+06 1.9462e+06
2531.5 1.3892e+07 1.3883e+07 1.3900e+07
2569.8 5.3460e+05 5.3416e+05 5.3504e+05
4398.1 5.0525e+06 5.0514e+06 5.0536e+06
6668.6 1.0221e+07 1.0215e+07 1.0226e+07
6698.2 9.2235e+06 9.2214e+06 9.2255e+06
6765.6 2.1925e+06 2.1912e+06 2.1937e+06
6793.6 1.3792e+05 1.3779e+05 1.3805e+05
9423.3 1.1806e+07 1.1804e+07 1.1808e+07
10062.8 6.9247e+06 6.9231e+06 6.9263e+06
10211.2 1.6982e+06 1.6970e+06 1.6994e+06
11431.5 9.9092e+04 9.8081e+04 1.0012e+05
12563.6 6.3580e+06 6.3337e+06 6.3826e+06
12675.7 3.0024e+05 2.9935e+05 3.0113e+05
13979.2 3.2738e+06 3.2702e+06 3.2773e+06
15862.0 1.0955e+07 1.0911e+07 1.1000e+07
15880.4 9.6743e+06 9.6714e+06 9.6772e+06
16118.9 7.7139e+06 7.7110e+06 7.7168e+06
18553.9 1.1010e+06 1.0951e+06 1.1070e+06
20323.0 2.9024e+06 2.8472e+06 2.9598e+06
21057.3 7.9677e+06 7.9231e+06 8.0129e+06
23260.9 6.3371e+06 6.3239e+06 6.3504e+06
24388.9 6.7833e+06 6.7652e+06 6.8014e+06
24763.0 3.1798e+06 3.1575e+06 3.2026e+06
26153.1 2.9557e+06 2.9440e+06 2.9676e+06
26167.4 4.4583e+06 4.4341e+06 4.4828e+06
26762.0 7.5887e+06 7.4226e+06 7.7623e+06
28598.1 6.4998e+06 6.4935e+06 6.5061e+06
29164.0 3.7171e+05 3.6012e+05 3.8407e+05
29985.5 6.7660e+06 6.7237e+06 6.8089e+06
30887.9 4.2386e+06 4.1974e+06 4.2807e+06
31630.0 2.9121e+06 2.9023e+06 2.9220e+06
31660.0 7.7734e+06 7.7553e+06 7.7916e+06
32320.0 2.5640e+06 2.4872e+06 2.6458e+06
2016-11-22 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1070.0 2.0387e+06 2.0263e+06 2.0513e+06
2531.4 1.3095e+07 1.3084e+07 1.3107e+07
2569.9 5.4137e+05 5.4076e+05 5.4198e+05
2596.0 6.0664e+04 5.0205e+04 7.6618e+04
3270.0 2.3507e+06 2.2920e+06 2.4124e+06
3364.4 1.5727e+07 1.5284e+07 1.6197e+07
3640.4 1.2485e+07 1.1993e+07 1.3020e+07
4398.1 4.9792e+06 4.9778e+06 4.9807e+06
5230.7 5.8211e+06 5.6113e+06 6.0471e+06
5506.9 5.5310e+06 5.2327e+06 5.8654e+06
6668.9 1.0132e+07 1.0124e+07 1.0141e+07
6698.2 9.2026e+06 9.1993e+06 9.2059e+06
6765.6 2.1984e+06 2.1972e+06 2.1996e+06
6793.5 1.3816e+05 1.3724e+05 1.3910e+05
9423.3 1.1839e+07 1.1836e+07 1.1842e+07
10062.8 6.9932e+06 6.9775e+06 7.0089e+06
10211.3 1.8418e+06 1.7438e+06 1.9514e+06
11431.5 1.0026e+05 9.9033e+04 1.0151e+05
12563.7 6.2767e+06 6.2281e+06 6.3261e+06
12675.8 3.0511e+05 3.0130e+05 3.0901e+05
13979.3 3.2395e+06 3.2354e+06 3.2436e+06
15862.1 1.1013e+07 1.0999e+07 1.1027e+07
15880.5 9.7162e+06 9.7120e+06 9.7204e+06
16119.0 7.7387e+06 7.7348e+06 7.7427e+06
18553.9 1.1033e+06 1.0932e+06 1.1135e+06
20044.6 5.8909e+05 5.7146e+05 6.0784e+05
20322.7 2.9553e+06 2.9055e+06 3.0069e+06
21057.2 8.0593e+06 8.0366e+06 8.0822e+06
23261.1 6.4567e+06 6.4296e+06 6.4841e+06
24389.0 6.8069e+06 6.7931e+06 6.8209e+06
24762.4 3.1729e+06 3.1563e+06 3.1895e+06
26152.9 3.0129e+06 2.9516e+06 3.0767e+06
26762.4 7.5311e+06 7.4757e+06 7.5873e+06
28598.3 6.5290e+06 6.4709e+06 6.5881e+06
28658.3 9.6595e+06 9.5903e+06 9.7297e+06
29985.3 6.5466e+06 6.5024e+06 6.5914e+06
30887.8 4.2070e+06 4.1757e+06 4.2387e+06
31630.0 2.9536e+06 2.9435e+06 2.9638e+06
31659.7 7.7449e+06 7.7254e+06 7.7644e+06
|
Attachment 1: spectra.png
|
|
208
|
Tue Nov 22 14:11:38 2016 |
Gabriele | General | Measurements | Laser polishing of bad disk improves Q, but they're still not very good |
Laser polishing of a sample from the second batch (S1600487, bad Q as out of the box) improves the Q values, but they're still lower than what we got with a good sample (S1600439, first batch)

|
Attachment 1: polishing_Qs.png
|
|
211
|
Mon Nov 28 10:35:54 2016 |
Gabriele | General | Measurements | S1600484 |
2016-11-28
- 10:25am, optical setup realigned to horizontal reference
- 10:35am, in chamber, balanced
- 10:40am, roughing pump on
- 10:52am, turbo pump on
- Excitations
-
Quiet time before excitation: 1164400002
Excitation (broad band) at 1164400035 (60 s)
Quiet time after excitation: 1164400097
-
Quiet time before excitation: 1164401563
Excitation (broad band) at 1164401595 (60 s)
Quiet time after excitation: 1164401657
-
2:22pm, pumps off
Results
2016-11-28 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1108.2 2.1286e+06 2.1260e+06 2.1311e+06
1128.2 1.4002e+06 1.3985e+06 1.4019e+06
2541.1 4.4285e+05 4.4093e+05 4.4478e+05
4425.7 1.0825e+06 1.0822e+06 1.0827e+06
4491.8 1.7184e+05 1.7171e+05 1.7197e+05
6751.2 7.5249e+05 7.5201e+05 7.5298e+05
6767.2 9.1922e+06 9.1856e+06 9.1989e+06
6828.1 7.0851e+05 7.0832e+05 7.0870e+05
6892.4 9.0766e+04 8.9716e+04 9.1840e+04
9508.3 6.6234e+05 6.6198e+05 6.6269e+05
10200.6 2.6975e+06 2.6967e+06 2.6982e+06
10354.1 1.3746e+06 1.3722e+06 1.3771e+06
12687.9 5.2322e+05 5.2266e+05 5.2378e+05
12814.7 2.1385e+05 2.0733e+05 2.2078e+05
14162.0 2.4004e+06 2.3937e+06 2.4071e+06
16066.5 8.3368e+05 8.2756e+05 8.3989e+05
16080.9 4.6121e+06 4.6067e+06 4.6174e+06
16292.8 4.4889e+05 4.4768e+05 4.5011e+05
18623.2 1.1736e+06 1.1720e+06 1.1753e+06
20216.5 3.1139e+05 3.0998e+05 3.1281e+05
20269.5 3.9574e+05 3.9231e+05 3.9923e+05
21341.7 3.5609e+06 3.5503e+06 3.5716e+06
23548.5 1.0547e+06 1.0459e+06 1.0636e+06
24675.0 4.8722e+05 4.8369e+05 4.9081e+05
27114.5 3.2593e+06 3.2316e+06 3.2876e+06
28847.0 6.4298e+05 6.3580e+05 6.5031e+05
29042.8 9.0053e+06 8.9598e+06 9.0514e+06
29541.5 3.0418e+05 3.0008e+05 3.0840e+05
2016-11-28 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1108.0 2.2446e+06 2.2430e+06 2.2461e+06
1128.0 1.4273e+06 1.4259e+06 1.4287e+06
2541.1 5.5421e+05 5.5231e+05 5.5613e+05
4425.7 1.1296e+06 1.1292e+06 1.1300e+06
4491.7 1.7340e+05 1.7315e+05 1.7364e+05
6751.2 7.9555e+05 7.9513e+05 7.9598e+05
6828.1 7.2886e+05 7.2829e+05 7.2944e+05
6892.3 9.0531e+04 8.9920e+04 9.1150e+04
9508.4 6.8801e+05 6.8618e+05 6.8985e+05
10200.6 2.8353e+06 2.8293e+06 2.8413e+06
10354.2 1.3806e+06 1.3748e+06 1.3865e+06
12687.9 5.4251e+05 5.4151e+05 5.4351e+05
14162.1 2.5067e+06 2.5040e+06 2.5094e+06
16066.6 8.5525e+05 8.5256e+05 8.5796e+05
16081.0 4.7931e+06 4.7882e+06 4.7979e+06
16292.8 4.7076e+05 4.7014e+05 4.7138e+05
18623.3 1.1982e+06 1.1952e+06 1.2012e+06
20216.7 3.2637e+05 3.2410e+05 3.2868e+05
20270.0 4.0768e+05 4.0103e+05 4.1455e+05
21341.9 3.7598e+06 3.7510e+06 3.7686e+06
24675.0 4.9703e+05 4.9246e+05 5.0169e+05
27115.0 3.3173e+06 3.2448e+06 3.3930e+06
28846.8 6.8259e+05 6.7698e+05 6.8830e+05
29043.0 9.1345e+06 9.1187e+06 9.1503e+06
29541.6 3.1186e+05 3.0790e+05 3.1591e+05
32140.0 2.7203e+06 2.6578e+06 2.7857e+06
|
212
|
Mon Nov 28 15:06:09 2016 |
Gabriele | General | Measurements | MIT sample 1 (bare disk) |
2016-11-28
- 3:00pm: removed the retaining ring and the alignment pins
- 3:05pm, 100mm/0.5mm disk installed, balanced
- 3:06pm, roughing pump on
- 3:19pm, turbo pump on
- Excitations:
- quiet time before 1164414276
band pass 100-3000 Hz, amplitude 3 x 2 kV, 60 seconds
quiet time after 1164414439
-
Quiet time before excitation: 1164426582
Excitation (broad band) at 1164426615 (60 s)
Quiet time after excitation: 1164426677
-
Quiet time before excitation: 1164437507
Excitation (broad band) at 1164437539 (60 s)
Quiet time after excitation: 1164437601
-
Quiet time before excitation: 1164448433
Excitation (broad band) at 1164448465 (60 s)
Quiet time after excitation: 1164448527
2016-11-29
Results
2016-11-28 A
 

% Freq Q1 Q2
315.9 2.8096e+06 2.8096e+06
726.7 1.8635e+06 1.8635e+06
1265.9 1.4194e+06 1.4029e+06
1930.4 1.1427e+06 1.1427e+06
1945.3 3.8068e+06 3.8068e+06
2717.9 9.7820e+05 9.6825e+05
2937.1 2.9339e+06 2.8810e+06
3626.4 8.4222e+05 8.4139e+05
4082.7 2.4345e+06 2.3090e+06
4638.8 5.2362e+06 5.1759e+06
4654.2 7.4042e+05 7.4042e+05
5374.9 1.9928e+06 1.9928e+06
5800.3 6.7081e+05 6.6269e+05
6164.3 4.0627e+06 3.8329e+06
6808.9 1.8131e+06 1.7073e+06
7063.0 6.2208e+05 6.2066e+05
7849.1 3.0518e+06 3.0518e+06
8381.5 1.6107e+06 1.6105e+06
10089.4 1.3860e+06 1.3793e+06
10476.0 4.6551e+06 4.6551e+06
12692.5 3.7473e+06 3.7473e+06
2016-11-28 B
 

% Freq Q1 Q2
316.2 2.9559e+06 2.9559e+06
726.7 1.9471e+06 1.9471e+06
1265.9 1.4767e+06 1.4596e+06
1324.0 1.7317e+06 1.7317e+06
1930.3 1.1866e+06 1.1826e+06
1945.2 3.8606e+06 3.8606e+06
2247.0 1.2821e+06 1.2442e+06
2717.8 1.0111e+06 9.8894e+05
2936.9 2.9926e+06 2.9494e+06
3626.2 8.6881e+05 8.6809e+05
4082.4 2.4804e+06 2.3513e+06
4638.7 5.2732e+06 5.1865e+06
4654.1 7.6228e+05 7.6228e+05
5374.6 2.0240e+06 2.0240e+06
5800.0 6.8894e+05 6.7200e+05
6164.1 3.9378e+06 3.9270e+06
6808.7 1.8616e+06 1.7343e+06
7062.7 6.2617e+05 6.2617e+05
7849.0 3.1323e+06 3.1323e+06
8381.2 1.6487e+06 1.5110e+06
8419.4 6.2761e+06 6.0088e+06
9687.4 2.6263e+06 2.6263e+06
10088.7 1.4209e+06 1.4209e+06
10475.5 4.5819e+06 3.9452e+06
11929.4 2.0706e+06 8.4521e+05
13900.0 1.1087e+06 1.1087e+06
2016-11-29 C
 

% Freq Q1 Q2
316.1 3.0133e+06 3.0133e+06
726.7 1.9621e+06 1.9621e+06
1265.8 1.4754e+06 1.4754e+06
1324.0 1.5486e+06 1.5486e+06
1930.3 1.1968e+06 1.1968e+06
1945.2 3.8326e+06 3.8326e+06
2717.8 1.0236e+06 9.9498e+05
2937.0 3.0102e+06 2.9815e+06
3626.2 8.7624e+05 8.7624e+05
4082.3 2.4965e+06 2.3709e+06
4638.6 5.2551e+06 5.2551e+06
4654.0 7.6848e+05 7.6176e+05
5374.4 2.0713e+06 2.0713e+06
6164.0 4.6657e+06 4.6657e+06
6808.7 1.8860e+06 1.7018e+06
8381.1 1.6553e+06 1.6553e+06
8419.0 6.3696e+06 6.3696e+06
|
214
|
Tue Nov 29 11:26:46 2016 |
Gabriele | General | Measurements | MIT sample 2 (disk with 4 1"/0.1mm glued blanks) |
2016-11-19
 
- 11:24am, in chamber, balanced. Installed with the four glued blanks facing down
- 11:25am, roughing pump on
- 11:35am, turbo pump on
- Excitations
-
~2:40pm, Roughing pump off
-
Reduced excitation amplitude by a factor 2
-
Increased excitation back to original value
-
Quiet time before excitation: 1164497423
Excitation (broad band) at 1164497455 (60 s)
Quiet time after excitation: 1164497517
-
Quiet time before excitation: 1164498267
Excitation (broad band) at 1164498300 (60 s)
Quiet time after excitation: 1164498362
-
Quiet time before excitation: 1164499112
Excitation (broad band) at 1164499144 (60 s)
Quiet time after excitation: 1164499206
- 4:01pm, turbo pump off
Results
2016-11-28 B
 

% Freq Q1 Q2
329.0 8.4824e+04 8.4824e+04
335.7 1.4025e+05 1.4025e+05
440.4 9.8646e+03 9.8646e+03
497.0 9.0449e+03 9.0449e+03
776.2 9.3536e+04 9.3536e+04
1112.1 7.1969e+03 7.1969e+03
1350.2 8.7756e+04 8.7756e+04
1358.5 7.4121e+04 7.4121e+04
1552.4 1.8858e+04 1.8858e+04
1609.0 3.3215e+04 3.3215e+04
1784.0 1.1629e+04 1.1629e+04
1798.6 2.0767e+04 2.0767e+04
1888.4 1.7837e+04 1.7837e+04
1945.0 3.3859e+04 3.3859e+04
2030.0 1.0957e+04 1.0957e+04
2050.5 7.5373e+04 7.5373e+04
2080.0 8.8890e+04 8.8890e+04
2134.5 1.1641e+04 1.1641e+04
2416.0 2.1993e+04 2.1993e+04
2470.5 2.7733e+04 2.7733e+04
2520.0 2.2354e+04 2.2354e+04
2527.0 4.5688e+04 4.5688e+04
2856.0 2.0405e+04 2.0405e+04
2874.4 5.1657e+04 5.1657e+04
3192.0 4.0038e+04 4.0038e+04
3438.0 2.4531e+04 2.4531e+04
3528.0 4.3625e+04 4.3625e+04
3810.3 8.4299e+04 8.4299e+04
3812.7 8.4331e+04 8.4331e+04
4214.0 4.5810e+04 4.5810e+04
4379.8 1.2693e+05 1.2693e+05
4550.5 4.2404e+04 4.2404e+04
4867.4 8.2873e+04 8.2873e+04
4870.5 7.8134e+04 7.8134e+04
2016-11-28 D
 

% Freq Q1 Q2
335.6 1.4056e+05 1.4056e+05
672.0 1.5677e+05 1.5677e+05
777.6 9.2059e+04 9.2059e+04
1112.7 1.0553e+05 1.0553e+05
1203.1 5.5487e+04 5.5487e+04
1350.1 8.4536e+04 8.4536e+04
1358.4 7.1777e+04 7.1777e+04
1714.6 7.2616e+04 7.2616e+04
2050.5 7.6493e+04 7.6493e+04
2080.0 8.7699e+04 8.7699e+04
2098.0 9.7959e+04 9.7959e+04
2416.0 1.0540e+05 1.0540e+05
2874.4 5.6525e+04 5.6525e+04
3128.9 2.3520e+04 2.3520e+04
3134.3 2.0219e+04 2.0219e+04
3810.5 8.7060e+04 8.7060e+04
3812.5 8.7089e+04 8.7089e+04
4323.4 5.2924e+04 5.2924e+04
4379.8 1.2308e+05 1.2308e+05
4867.1 8.1170e+04 8.1170e+04
4870.4 8.9835e+04 8.9835e+04
5704.3 6.9120e+04 6.9120e+04
5728.4 6.6924e+04 6.6924e+04
6033.9 7.5637e+04 7.5637e+04
6036.0 8.0112e+04 8.0112e+04
7204.0 1.0233e+05 1.0233e+05
8625.9 1.4731e+05 1.4731e+05
|
Attachment 2: 2016-11-29_11.17.13.jpg
|
|
Attachment 6: results_2016_11_28b.png
|
|
Attachment 10: results_2016_11_28d.png
|
|
215
|
Tue Nov 29 16:42:51 2016 |
Gabriele | General | Measurements | MIT sample 3 (disk with 4 0.5"/0.125" glued blanks) |
2016-11-29
 
- 4:40pm, in chamber, blanks facing down
- 4:41pm, roughing pump on
- 4:53pm, turbo pump on
- Injections:
-
Quiet time before excitation: 1164516798
Excitation (broad band) at 1164516830 (60 s)
Quiet time after excitation: 1164516892
-
Quiet time before excitation: 1164518722
Excitation (broad band) at 1164518754 (60 s)
Quiet time after excitation: 1164518816
-
Quiet time before excitation: 1164520646
Excitation (broad band) at 1164520678 (60 s)
Quiet time after excitation: 1164520740
-
Quiet time before excitation: 1164522570
Excitation (broad band) at 1164522602 (60 s)
Quiet time after excitation: 1164522664
-
Quiet time before excitation: 1164524494
Excitation (broad band) at 1164524526 (60 s)
Quiet time after excitation: 1164524588
-
Quiet time before excitation: 1164526419
Excitation (broad band) at 1164526451 (60 s)
Quiet time after excitation: 1164526513
2016-11-30
Results
2016-11-29 A
 

% Freq Q1 Q2
251.9 2.8630e+04 2.8630e+04
270.6 4.3984e+04 4.3984e+04
329.0 5.2792e+04 5.2792e+04
387.4 6.4408e+04 6.4408e+04
692.9 2.1202e+04 2.1202e+04
705.5 2.7294e+04 2.7294e+04
1121.5 1.9490e+04 1.9490e+04
1127.2 2.3102e+04 2.3102e+04
1242.2 1.6168e+04 1.6168e+04
1318.1 2.5395e+04 2.5395e+04
1800.6 2.3235e+04 2.3235e+04
2124.1 1.8960e+04 1.8960e+04
2797.5 9.8183e+03 9.8183e+03
2841.8 1.1002e+04 1.1002e+04
2921.3 1.2820e+04 1.2820e+04
2959.7 7.8878e+03 7.8878e+03
3701.0 8.0007e+03 8.0007e+03
3839.4 1.3538e+04 1.3538e+04
4692.3 3.4420e+04 3.4420e+04
2016-11-29 B
 

% Freq Q1 Q2
251.9 2.6513e+04 2.6513e+04
329.0 5.4964e+04 5.4964e+04
387.0 5.9983e+04 5.9983e+04
692.9 2.4150e+04 2.4150e+04
705.4 2.7301e+04 2.7301e+04
1127.3 1.8674e+04 1.8674e+04
1242.1 1.2792e+04 1.2792e+04
1318.1 2.4187e+04 2.4187e+04
1800.7 2.2498e+04 2.2498e+04
2124.2 1.8534e+04 1.8534e+04
2797.5 9.8734e+03 9.8734e+03
2841.6 1.2921e+04 1.2921e+04
2959.8 1.0940e+04 1.0940e+04
3400.4 1.5128e+04 1.5128e+04
3700.7 1.0732e+04 1.0732e+04
4692.2 4.3243e+04 4.3243e+04
2016-11-29 C
 

% Freq Q1 Q2
251.6 2.8079e+04 2.8079e+04
271.0 4.1437e+04 4.1437e+04
329.0 5.4328e+04 5.4328e+04
387.4 5.8614e+04 5.8614e+04
692.8 2.2689e+04 2.2689e+04
705.5 2.8442e+04 2.8442e+04
1127.2 1.8216e+04 1.8216e+04
1242.0 1.8455e+04 1.8455e+04
1317.8 2.3628e+04 2.3628e+04
1800.6 2.2896e+04 2.2896e+04
2124.2 1.8450e+04 1.8450e+04
2797.7 1.0904e+04 1.0904e+04
2841.8 1.4721e+04 1.4721e+04
2921.4 1.0612e+04 1.0612e+04
2959.8 1.0875e+04 1.0875e+04
3700.7 1.1009e+04 1.1009e+04
3705.3 1.0344e+04 1.0344e+04
3839.3 1.3205e+04 1.3205e+04
4110.4 1.3077e+04 1.3077e+04
4692.3 4.8605e+04 4.8605e+04
|
Attachment 5: results_2016_11_29a.png
|
|
Attachment 9: results_2016_11_29b.png
|
|
218
|
Wed Nov 30 10:02:20 2016 |
Gabriele | General | Measurements | MIT sample 4 (disk with 3 1"/0.1mm glued blanks) |
2016-11-30
 
- 9:57am, in chamber, balanced, glued balnks facing down
- 9:59am, roughing pump on
- 10:09am, turbo pump on
- Excitations
-
Quiet time before excitation: 1164570059
Excitation (broad band) at 1164570091 (60 s)
Quiet time after excitation: 1164570153
-
Quiet time before excitation: 1164571983
Excitation (broad band) at 1164572015 (60 s)
Quiet time after excitation: 1164572077
-
Quiet time before excitation: 1164573907
Excitation (broad band) at 1164573939 (60 s)
Quiet time after excitation: 1164574001
-
Quiet time before excitation: 1164575831
Excitation (broad band) at 1164575863 (60 s)
Quiet time after excitation: 1164575925
-
3:34pm, pumps off
Results
2016-11-30 A
 

% Freq Q1 Q2
329.0 8.3663e+04 8.3663e+04
764.8 6.6913e+04 6.6913e+04
1093.6 7.4978e+04 7.4978e+04
1173.2 4.7789e+04 4.7789e+04
1333.5 5.8904e+04 5.8904e+04
1529.0 6.9659e+04 6.9659e+04
1597.4 1.0552e+05 1.0552e+05
1748.0 4.8237e+04 4.8237e+04
2007.8 3.8014e+04 3.8014e+04
2017.3 6.4686e+04 6.4686e+04
2066.8 4.6047e+04 4.6047e+04
2077.3 5.7698e+04 5.7698e+04
2832.1 4.1680e+04 4.1680e+04
2850.9 6.3764e+04 6.3764e+04
3101.5 2.6027e+04 2.6027e+04
3468.7 1.9827e+04 1.9827e+04
3784.7 3.5492e+04 3.5492e+04
4301.1 3.6826e+04 3.6826e+04
4822.6 6.6123e+04 6.6123e+04
4834.9 4.6789e+04 4.6789e+04
6014.6 6.6507e+04 6.6507e+04
2016-11-30 B
 

% Freq Q
328.8 8.5064e+04
764.6 6.7065e+04
1093.6 6.4289e+04
1173.2 4.7921e+04
1333.5 5.8311e+04
1529.0 6.4720e+04
1597.4 1.5015e+05
1748.4 4.2924e+04
2007.7 4.1694e+04
2017.4 6.3609e+04
2067.0 4.6240e+04
2077.2 5.8395e+04
2406.0 4.5908e+04
2832.1 4.5323e+04
2851.0 6.4089e+04
3101.5 2.9677e+04
3468.7 1.6697e+04
3784.5 2.1703e+04
4299.7 3.7688e+04
4835.1 4.6841e+04
5659.7 3.4913e+04
2016-11-30 C
 

% Freq Q
329.1 8.3839e+04
658.0 8.6457e+04
764.6 6.6619e+04
1093.7 7.3246e+04
1163.3 2.7214e+04
1172.5 4.1708e+04
1333.7 5.9429e+04
1597.4 1.4036e+05
1748.0 2.8271e+04
2007.8 4.7532e+04
2017.4 6.5563e+04
2067.0 4.5528e+04
2077.2 5.8753e+04
2346.0 3.4762e+04
2832.1 3.9431e+04
2851.1 6.4498e+04
3101.5 3.0334e+04
3469.0 1.6427e+04
3784.7 5.0161e+04
4299.8 4.0081e+04
4835.2 5.3962e+04
4860.0 5.4326e+04
5659.8 3.5224e+04
6015.4 4.6382e+04
8739.5 4.7841e+04
|
Attachment 2: 2016-11-30_09.57.45.jpg
|
|
219
|
Thu Dec 1 11:55:09 2016 |
Gabriele | General | Measurements | S1600433 |
Note: sample deep cleaned by GariLynn
2016-12-01
- 11:45am, installed back the movable alignment ring, realigned optical setup to horizontal reference
- 11:52am, sample in chamber, balanced
- 11:54am, roughing pump on
- 12:06pm, turbo pump on
- Excitations
-
Quiet time before excitation: 1164664951
Excitation (broad band) at 1164665116 (60 s)
Quiet time after excitation: 1164665178
-
Quiet time before excitation: 1164676008
Excitation (broad band) at 1164676041 (60 s)
Quiet time after excitation: 1164676103
-
Quiet time before excitation: 1164686933
Excitation (broad band) at 1164686965 (60 s)
Quiet time after excitation: 1164687027
2016-12-02
Results
2016-12-01 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1112.0 5.4758e+06 5.4729e+06 5.4787e+06
2550.1 2.3526e+06 2.3516e+06 2.3535e+06
3382.9 3.0202e+06 3.0098e+06 3.0307e+06
3653.0 1.9478e+06 1.8176e+06 2.0980e+06
3661.7 2.7811e+06 2.7725e+06 2.7898e+06
4442.3 2.1488e+06 2.1482e+06 2.1493e+06
5100.1 2.2806e+06 2.2621e+06 2.2994e+06
6777.9 1.8246e+06 1.8243e+06 1.8249e+06
6788.5 8.1295e+06 8.1231e+06 8.1360e+06
6858.4 1.1642e+06 1.1639e+06 1.1645e+06
9548.2 1.4693e+06 1.4689e+06 1.4697e+06
10233.4 5.5505e+06 5.5477e+06 5.5533e+06
10395.9 1.7065e+06 1.7020e+06 1.7110e+06
12744.0 1.2980e+06 1.2957e+06 1.3003e+06
12877.4 5.4532e+05 5.4335e+05 5.4731e+05
14209.0 5.1790e+06 5.1761e+06 5.1819e+06
16123.1 1.2440e+06 1.2389e+06 1.2492e+06
16368.9 1.1801e+06 1.1759e+06 1.1842e+06
18686.0 3.7107e+06 3.6795e+06 3.7424e+06
20365.0 4.7226e+05 4.6383e+05 4.8101e+05
21414.0 8.2349e+06 8.2195e+06 8.2503e+06
23628.1 3.4507e+06 3.4303e+06 3.4714e+06
24797.0 9.7549e+05 9.5712e+05 9.9458e+05
27208.4 6.8971e+06 6.8561e+06 6.9387e+06
28943.4 2.1728e+06 2.1506e+06 2.1954e+06
29052.0 1.6619e+06 1.6301e+06 1.6950e+06
2016-12-01 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1111.6 5.5847e+06 5.5812e+06 5.5883e+06
2266.3 1.3702e+06 1.3669e+06 1.3734e+06
2549.9 2.5450e+06 2.5440e+06 2.5460e+06
4441.9 2.1936e+06 2.1932e+06 2.1940e+06
6777.6 1.8629e+06 1.8627e+06 1.8632e+06
6788.7 8.2746e+06 8.2724e+06 8.2768e+06
6858.2 1.0572e+06 1.0570e+06 1.0574e+06
9547.9 1.5059e+06 1.5015e+06 1.5104e+06
10232.8 5.6628e+06 5.6586e+06 5.6670e+06
10395.5 1.7751e+06 1.7661e+06 1.7841e+06
12743.6 1.3335e+06 1.3303e+06 1.3366e+06
12876.9 5.6054e+05 5.5828e+05 5.6281e+05
14208.4 5.3425e+06 5.3382e+06 5.3467e+06
16122.6 1.2447e+06 1.2410e+06 1.2483e+06
16368.3 1.2426e+06 1.2345e+06 1.2507e+06
20364.4 4.2334e+05 4.1748e+05 4.2936e+05
21413.3 8.0393e+06 7.9669e+06 8.1131e+06
23627.2 3.5157e+06 3.4930e+06 3.5387e+06
24056.0 1.2755e+06 1.2481e+06 1.3041e+06
24796.0 1.0108e+06 1.0054e+06 1.0162e+06
27207.0 7.1155e+06 7.0025e+06 7.2323e+06
28942.4 2.1872e+06 2.1597e+06 2.2154e+06
29051.0 1.7084e+06 1.6660e+06 1.7531e+06
31093.6 6.3519e+05 6.2958e+05 6.4090e+05
2016-12-1 C
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1111.6 5.6533e+06 5.6500e+06 5.6566e+06
2549.9 2.6212e+06 2.6202e+06 2.6223e+06
2559.0 2.1495e+06 2.0914e+06 2.2109e+06
4441.9 2.2212e+06 2.2200e+06 2.2224e+06
6777.6 1.8851e+06 1.8847e+06 1.8855e+06
6789.0 8.3315e+06 8.3301e+06 8.3330e+06
6858.0 9.6935e+05 9.6913e+05 9.6957e+05
9547.6 1.5145e+06 1.5142e+06 1.5148e+06
10232.7 5.8532e+06 5.8516e+06 5.8549e+06
10395.3 1.7902e+06 1.7892e+06 1.7912e+06
12743.3 1.3459e+06 1.3452e+06 1.3465e+06
12876.7 5.7790e+05 5.7717e+05 5.7863e+05
14208.1 5.3736e+06 5.3686e+06 5.3786e+06
16122.2 1.3398e+06 1.3364e+06 1.3433e+06
16368.0 1.2740e+06 1.2713e+06 1.2767e+06
21412.7 8.0909e+06 8.0738e+06 8.1080e+06
23626.7 3.5651e+06 3.5395e+06 3.5909e+06
24795.2 1.0188e+06 1.0092e+06 1.0285e+06
28941.6 2.2120e+06 2.1966e+06 2.2277e+06
|
221
|
Fri Dec 2 10:56:40 2016 |
Gabriele | General | Measurements | Cleaning improves the Q values a bit |
The plot below compares the measured Q values of S1600433 right after annealing, and after GariLynn cleaned it. Q values are in general improved a bit after cleaning.

|
Attachment 1: cleaning.png
|
|
222
|
Fri Dec 2 11:20:56 2016 |
Gabriele | General | Measurements | S1600484 after laser polishing |
2016-12-02
- 11:08am, in chamber, balanced
- 11:10am, roughing pump on
- 11:20am, turbo pump on
- Excitations:
- Quiet time before excitation: 1164752200
Quiet time after excitation: 1164752486
-
Quiet time before excitation: 1164763364
Excitation (broad band) at 1164763397 (60 s)
Quiet time after excitation: 1164763459
-
Quiet time before excitation: 1164774289
Excitation (broad band) at 1164774322 (60 s)
Quiet time after excitation: 1164774384
-
Quiet time before excitation: 1164785214
Excitation (broad band) at 1164785246 (60 s)
Quiet time after excitation: 1164785308
2016-12-05
Results
2016-12-02 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1123.6 4.4547e+07 4.4226e+07 4.4872e+07
1144.4 1.6095e+06 1.6080e+06 1.6111e+06
2507.2 1.9029e+07 1.8865e+07 1.9196e+07
2565.7 2.1672e+07 2.1661e+07 2.1682e+07
2606.5 1.0177e+06 1.0172e+06 1.0182e+06
2623.7 2.0058e+07 1.9885e+07 2.0233e+07
4457.8 2.8825e+06 2.8820e+06 2.8831e+06
4516.0 2.6781e+06 2.6373e+06 2.7203e+06
6732.1 1.7486e+07 1.7413e+07 1.7561e+07
6762.2 2.8949e+07 2.8860e+07 2.9037e+07
6790.3 1.8633e+07 1.8630e+07 1.8635e+07
6848.5 1.7815e+07 1.7740e+07 1.7891e+07
6865.9 7.9181e+05 7.9078e+05 7.9284e+05
9554.0 7.0446e+06 7.0433e+06 7.0458e+06
10202.5 8.8916e+06 8.8889e+06 8.8942e+06
10359.4 2.3946e+06 2.3839e+06 2.4054e+06
12739.3 2.2738e+06 2.2716e+06 2.2761e+06
12862.8 1.0330e+06 1.0289e+06 1.0371e+06
14171.9 5.1086e+06 5.0988e+06 5.1184e+06
16096.9 1.9349e+07 1.9326e+07 1.9373e+07
16348.0 8.4181e+06 8.4141e+06 8.4222e+06
18641.8 6.9884e+05 6.8917e+05 7.0877e+05
18815.5 7.5157e+05 7.3926e+05 7.6430e+05
19704.4 2.3376e+06 2.2789e+06 2.3995e+06
20273.5 1.0526e+06 1.0311e+06 1.0750e+06
20328.5 7.7314e+06 7.6796e+06 7.7839e+06
23576.6 1.1741e+07 1.1730e+07 1.1751e+07
24737.7 3.0533e+06 3.0023e+06 3.1059e+06
25614.3 4.3903e+06 4.3015e+06 4.4828e+06
27132.2 9.7722e+06 9.7162e+06 9.8289e+06
28887.1 1.4755e+07 1.4722e+07 1.4789e+07
28987.2 1.2025e+07 1.2004e+07 1.2045e+07
29051.1 1.3645e+07 1.3564e+07 1.3728e+07
2016-12-02 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1124.0 4.7359e+07 4.6976e+07 4.7747e+07
1144.5 1.6369e+06 1.6353e+06 1.6385e+06
2566.0 2.2381e+07 2.2368e+07 2.2393e+07
2606.6 1.0081e+06 1.0075e+06 1.0088e+06
4458.0 2.8784e+06 2.8774e+06 2.8794e+06
4516.0 2.9668e+06 2.8935e+06 3.0440e+06
6762.6 2.9139e+07 2.9072e+07 2.9207e+07
6790.6 1.9114e+07 1.9109e+07 1.9120e+07
9554.5 6.8250e+06 6.8030e+06 6.8471e+06
10203.1 8.7899e+06 8.7697e+06 8.8102e+06
12740.0 2.4202e+06 2.3984e+06 2.4424e+06
12863.4 1.0943e+06 1.0904e+06 1.0982e+06
14172.7 5.0284e+06 5.0177e+06 5.0391e+06
16083.0 2.0692e+07 2.0436e+07 2.0954e+07
16097.8 1.9626e+07 1.9621e+07 1.9632e+07
16348.8 8.5943e+06 8.5814e+06 8.6073e+06
19702.0 2.3940e+06 2.3434e+06 2.4468e+06
20329.4 8.0641e+06 8.0297e+06 8.0988e+06
23578.0 1.0707e+07 1.0675e+07 1.0740e+07
24739.0 3.2440e+06 3.1722e+06 3.3191e+06
27134.0 9.9640e+06 9.7155e+06 1.0226e+07
28888.5 1.5363e+07 1.5278e+07 1.5449e+07
28989.0 1.1648e+07 1.1623e+07 1.1672e+07
29052.5 1.3554e+07 1.3321e+07 1.3795e+07
29499.4 7.0586e+06 6.9311e+06 7.1908e+06
31172.0 3.4291e+06 3.3377e+06 3.5257e+06
2016-12-02 C
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1124.0 4.6838e+07 4.6384e+07 4.7300e+07
1144.4 1.6698e+06 1.6673e+06 1.6723e+06
2507.0 2.0602e+07 1.9878e+07 2.1380e+07
2565.9 2.2525e+07 2.2512e+07 2.2537e+07
2606.6 9.8280e+05 9.8213e+05 9.8346e+05
2623.7 2.1807e+07 2.1557e+07 2.2063e+07
3899.0 3.0267e+04 2.9315e+04 3.1283e+04
4458.1 2.7345e+06 2.7334e+06 2.7356e+06
6732.5 1.9119e+07 1.8913e+07 1.9331e+07
6762.8 2.9093e+07 2.9009e+07 2.9178e+07
6790.8 1.9322e+07 1.9319e+07 1.9326e+07
6849.1 1.9659e+07 1.8960e+07 2.0411e+07
9554.7 6.7030e+06 6.6940e+06 6.7121e+06
10203.4 8.7345e+06 8.7251e+06 8.7439e+06
12740.2 2.5144e+06 2.5080e+06 2.5208e+06
12863.7 1.1036e+06 1.1020e+06 1.1052e+06
14173.1 4.8696e+06 4.8578e+06 4.8816e+06
16098.1 1.9691e+07 1.9678e+07 1.9704e+07
16349.2 8.7666e+06 8.7590e+06 8.7743e+06
18643.4 1.2705e+06 1.2651e+06 1.2760e+06
20275.1 6.7929e+05 6.7513e+05 6.8350e+05
20330.0 8.2770e+06 8.2439e+06 8.3104e+06
23578.5 9.5784e+06 9.5536e+06 9.6034e+06
27134.5 1.0034e+07 9.9648e+06 1.0104e+07
28889.4 1.5698e+07 1.5572e+07 1.5827e+07
28989.3 1.0586e+07 1.0515e+07 1.0658e+07
31205.0 7.2273e+05 7.0149e+05 7.4531e+05
|
225
|
Mon Dec 5 12:59:48 2016 |
Gabriele | General | Measurements | S1600485 post laser polishing |
2016-12-05
- 12:45pm, in chamber, balanced
- 12:46pm, roughing pump on
- 12:59pm, turbo pump on
- Excitations:
-
Quiet time before excitation: 1165019273
Excitation (broad band) at 1165019305 (60 s)
Quiet time after excitation: 1165019367
-
Quiet time before excitation: 1165033797
Excitation (broad band) at 1165033829 (60 s)
Quiet time after excitation: 1165033891
-
Quiet time before excitation: 1165048321
Excitation (broad band) at 1165048353 (60 s)
Quiet time after excitation: 1165048415
2016-12-06
- Excitations:
-
11:02am, pumps off
|
230
|
Tue Dec 6 14:57:33 2016 |
Gabriele | General | Measurements | S1600486 post laser polishing |
Note: marked as scratched by Alena
2016-12-06
- 2:44pm, in chamber, balanced
- 2:46pm, roughing pump on
- 2:57pm, turbo pump on
- Excitations:
-
Quiet time before excitation: 1165111173
Excitation (broad band) at 1165111205 (60 s)
Quiet time after excitation: 1165111267
-
Quiet time before excitation: 1165125697
Excitation (broad band) at 1165125729 (60 s)
Quiet time after excitation: 1165125791
-
Quiet time before excitation: 1165140221
Excitation (broad band) at 1165140253 (60 s)
Quiet time after excitation: 1165140315
2012-12-07
Results
2016-11-06 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1109.7 4.0692e+07 4.0198e+07 4.1198e+07
1130.4 2.3580e+06 2.3557e+06 2.3604e+06
2533.1 7.2674e+05 7.2562e+05 7.2786e+05
2574.5 5.5540e+04 5.5210e+04 5.5875e+04
4401.1 2.5934e+07 2.5895e+07 2.5973e+07
6677.0 1.1663e+07 1.1655e+07 1.1671e+07
6703.7 1.8348e+06 1.8328e+06 1.8367e+06
6777.9 2.7639e+06 2.7614e+06 2.7664e+06
9432.0 4.2054e+05 4.1564e+05 4.2556e+05
10074.1 9.4578e+06 9.4442e+06 9.4714e+06
10230.6 1.4532e+06 1.4492e+06 1.4572e+06
10269.5 1.4339e+06 1.3237e+06 1.5641e+06
10272.5 1.5802e+06 1.4639e+06 1.7167e+06
12113.0 2.2279e+06 2.1313e+06 2.3336e+06
12551.0 5.5340e+06 5.3374e+06 5.7457e+06
12554.0 5.7261e+06 5.5380e+06 5.9273e+06
12576.7 5.2804e+06 5.2660e+06 5.2949e+06
12699.5 1.5337e+06 1.5252e+06 1.5423e+06
13995.0 6.9111e+06 6.8879e+06 6.9344e+06
15884.1 3.2752e+06 3.2367e+06 3.3146e+06
15893.1 6.3130e+06 6.2429e+06 6.3847e+06
16140.4 2.7621e+06 2.7335e+06 2.7913e+06
18082.4 3.2628e+06 3.2181e+06 3.3087e+06
18409.4 9.3191e+06 9.2638e+06 9.3749e+06
20070.5 2.6063e+06 2.5545e+06 2.6603e+06
21087.5 1.8021e+07 1.7921e+07 1.8121e+07
23270.0 6.6877e+06 6.2852e+06 7.1452e+06
23284.2 6.4198e+06 6.3502e+06 6.4909e+06
24426.4 5.9323e+06 5.7957e+06 6.0754e+06
26801.1 1.5681e+07 1.5517e+07 1.5848e+07
28528.9 9.4049e+06 9.2822e+06 9.5309e+06
30807.6 7.0927e+06 6.9400e+06 7.2523e+06
31637.3 4.9001e+06 4.7168e+06 5.0982e+06
2016-12-06 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1110.0 4.0898e+07 4.0699e+07 4.1098e+07
1130.4 2.4968e+06 2.4940e+06 2.4995e+06
2533.1 3.0816e+05 3.0712e+05 3.0921e+05
2574.6 5.1835e+04 5.1723e+04 5.1948e+04
4400.9 2.6081e+07 2.6051e+07 2.6110e+07
6676.8 1.4510e+07 1.4498e+07 1.4522e+07
6703.5 1.7594e+06 1.7575e+06 1.7614e+06
6777.9 2.5212e+06 2.5190e+06 2.5234e+06
9432.2 4.6496e+05 4.6114e+05 4.6885e+05
10041.0 8.9046e+06 8.7097e+06 9.1084e+06
10074.2 9.2417e+06 9.2291e+06 9.2544e+06
10118.0 9.3278e+06 9.1242e+06 9.5408e+06
10215.5 2.5297e+06 2.3859e+06 2.6918e+06
10230.5 1.4901e+06 1.4844e+06 1.4959e+06
12576.6 4.8231e+06 4.8087e+06 4.8375e+06
12699.5 1.5633e+06 1.5547e+06 1.5720e+06
13994.9 6.6141e+06 6.5947e+06 6.6336e+06
15883.1 2.9889e+06 2.9608e+06 3.0175e+06
15893.0 5.8882e+06 5.7626e+06 6.0194e+06
16140.5 2.3710e+06 2.3026e+06 2.4436e+06
18082.5 3.1473e+06 3.0782e+06 3.2196e+06
18409.5 8.9605e+06 8.8329e+06 9.0918e+06
20069.6 2.6341e+06 2.5542e+06 2.7192e+06
21087.5 2.2138e+07 2.1593e+07 2.2711e+07
23261.5 8.4257e+06 8.0368e+06 8.8541e+06
23284.2 7.7673e+06 7.6967e+06 7.8392e+06
24677.4 3.7815e+06 3.6917e+06 3.8759e+06
26800.7 1.5883e+07 1.5612e+07 1.6163e+07
28528.6 6.3924e+06 6.2850e+06 6.5035e+06
28547.0 6.6445e+06 6.3100e+06 7.0164e+06
28697.5 3.4170e+06 3.2882e+06 3.5564e+06
2016-12-06 C
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
1110.0 3.9831e+07 3.9595e+07 4.0070e+07
1130.4 2.5187e+06 2.5146e+06 2.5228e+06
2533.1 2.0051e+05 1.9944e+05 2.0158e+05
2574.7 5.0078e+04 4.9947e+04 5.0209e+04
4401.0 2.6148e+07 2.6116e+07 2.6180e+07
4466.0 1.9195e+05 1.8808e+05 1.9597e+05
6677.0 1.6348e+07 1.6334e+07 1.6362e+07
6703.5 1.7691e+06 1.7676e+06 1.7707e+06
6777.6 2.2974e+06 2.2951e+06 2.2997e+06
9432.0 4.9962e+05 4.9753e+05 5.0173e+05
9438.0 5.1125e+05 4.7959e+05 5.4738e+05
9440.0 5.2633e+05 4.8682e+05 5.7282e+05
10038.5 9.6023e+06 9.3617e+06 9.8556e+06
10074.1 8.9653e+06 8.9527e+06 8.9779e+06
10117.5 9.1766e+06 8.9495e+06 9.4154e+06
10230.4 1.5302e+06 1.5227e+06 1.5378e+06
12576.4 4.6067e+06 4.5948e+06 4.6186e+06
12699.5 1.5834e+06 1.5749e+06 1.5919e+06
13994.8 9.3708e+06 9.3458e+06 9.3960e+06
15883.5 2.8463e+06 2.8018e+06 2.8922e+06
15893.0 5.7257e+06 5.6080e+06 5.8485e+06
16140.1 1.4682e+06 1.4471e+06 1.4899e+06
18082.9 3.1445e+06 3.1008e+06 3.1894e+06
18410.0 9.7225e+06 9.5594e+06 9.8912e+06
20072.6 2.7615e+06 2.6596e+06 2.8716e+06
21087.0 1.8180e+07 1.8047e+07 1.8314e+07
23284.1 8.7746e+06 8.6857e+06 8.8653e+06
24426.3 4.6250e+06 4.5275e+06 4.7268e+06
24678.1 3.9254e+06 3.8243e+06 4.0320e+06
26801.1 1.5859e+07 1.5532e+07 1.6201e+07
28528.5 4.8476e+06 4.7219e+06 4.9801e+06
29936.0 1.0024e+07 9.7180e+06 1.0351e+07
30807.4 6.6210e+06 6.4586e+06 6.7918e+06
|
234
|
Wed Dec 7 09:59:59 2016 |
Gabriele | General | Measurements | MIT sample 3 (disk with 4 0.5"/0.125" glued blanks) second round |
2016-12-07
- Removed retaining ring and pins, aligned optical setup to horizontal reference
- 9:59am, in chamber, balanced
- 10:00am, roughing pump on
- 10:12am, turbo pump on
 
As visible in th second picture, the distance between the disk and the ESD is about 1.5 mm
- Excitations:
-
Quiet time before excitation: 1165178719
Excitation (broad band) at 1165178751 (60 s)
Quiet time after excitation: 1165178813
-
Quiet time before excitation: 1165180007
Excitation (broad band) at 1165180039 (60 s)
Quiet time after excitation: 1165180101
-
Quiet time before excitation: 1165181331
Excitation (broad band) at 1165181363 (60 s)
Quiet time after excitation: 1165181425
-
2:39pm, pumps off
Results
2016-12-07 A
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
251.8 2.9528e+04 2.9325e+04 2.9732e+04
323.4 6.9039e+04 6.5071e+04 7.3509e+04
328.7 5.5337e+04 5.5222e+04 5.5453e+04
692.8 2.4543e+04 2.4515e+04 2.4571e+04
705.5 2.7474e+04 2.7356e+04 2.7592e+04
1128.5 2.1332e+04 2.1268e+04 2.1395e+04
1242.4 1.2258e+04 1.2079e+04 1.2442e+04
1318.0 2.4548e+04 2.4419e+04 2.4678e+04
1800.7 2.6692e+04 2.6451e+04 2.6937e+04
1933.3 9.2002e+03 8.9167e+03 9.5022e+03
1937.7 8.5766e+03 8.5339e+03 8.6198e+03
2124.0 2.4927e+04 2.4872e+04 2.4982e+04
2799.2 8.1222e+03 7.9880e+03 8.2609e+03
2924.5 8.1070e+03 8.0349e+03 8.1804e+03
2964.4 8.2661e+03 8.1772e+03 8.3570e+03
4692.7 4.5716e+04 4.4885e+04 4.6578e+04
2016-12-07 B
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
251.7 2.8324e+04 2.8084e+04 2.8567e+04
329.0 5.4343e+04 5.4182e+04 5.4504e+04
692.7 2.4556e+04 2.4524e+04 2.4588e+04
705.5 2.7344e+04 2.7229e+04 2.7461e+04
1128.3 2.0844e+04 2.0548e+04 2.1148e+04
1242.1 1.2091e+04 1.1999e+04 1.2185e+04
1317.8 2.4709e+04 2.4659e+04 2.4760e+04
1322.0 2.8932e+04 2.6985e+04 3.1179e+04
1800.6 2.6879e+04 2.6691e+04 2.7069e+04
2123.6 2.4719e+04 2.4619e+04 2.4820e+04
2798.1 9.5908e+03 9.2072e+03 1.0008e+04
2841.0 1.1254e+04 1.0614e+04 1.1976e+04
2924.0 1.1666e+04 1.0395e+04 1.3291e+04
2963.1 9.7910e+03 9.3703e+03 1.0251e+04
3427.6 8.7265e+03 8.2911e+03 9.2102e+03
3700.2 1.4646e+04 1.3418e+04 1.6120e+04
4691.8 5.0056e+04 4.7715e+04 5.2638e+04
2016-12-07 C
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
251.8 2.8868e+04 2.8741e+04 2.8997e+04
313.8 4.8299e+04 4.4161e+04 5.3275e+04
658.0 4.5409e+04 4.4859e+04 4.5971e+04
692.6 2.4089e+04 2.3929e+04 2.4251e+04
705.4 2.7821e+04 2.7639e+04 2.8006e+04
1128.2 2.1583e+04 2.1087e+04 2.2103e+04
1242.1 1.2540e+04 1.2303e+04 1.2786e+04
1317.9 2.4663e+04 2.4626e+04 2.4700e+04
1571.0 1.4941e+04 1.4265e+04 1.5685e+04
1800.4 2.8559e+04 2.8113e+04 2.9019e+04
2123.4 2.7042e+04 2.6498e+04 2.7608e+04
2452.3 2.9667e+04 2.8231e+04 3.1256e+04
2797.4 8.7540e+03 8.0589e+03 9.5802e+03
2840.2 1.3484e+04 1.2967e+04 1.4043e+04
3706.5 1.0864e+04 1.0328e+04 1.1457e+04
4107.6 1.5757e+04 1.5573e+04 1.5946e+04
4690.7 4.8903e+04 4.7899e+04 4.9949e+04
2016-12-07 D
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
251.8 2.9311e+04 2.9189e+04 2.9434e+04
323.2 2.7246e+04 2.4352e+04 3.0908e+04
692.6 2.4309e+04 2.4226e+04 2.4392e+04
698.0 1.7009e+04 1.5425e+04 1.8954e+04
702.0 2.7209e+04 2.6645e+04 2.7796e+04
705.5 3.0025e+04 2.9300e+04 3.0785e+04
1127.6 2.0285e+04 1.9811e+04 2.0781e+04
1317.3 2.5325e+04 2.5209e+04 2.5442e+04
1800.3 3.2511e+04 3.1223e+04 3.3909e+04
1935.2 6.5014e+03 4.9517e+03 9.4607e+03
2122.5 2.8808e+04 2.7758e+04 2.9940e+04
2795.4 1.0237e+04 8.7193e+03 1.2393e+04
4688.8 4.9909e+04 4.1120e+04 6.3475e+04
6847.5 7.9848e+03 7.7352e+03 8.2510e+03
|
238
|
Fri Dec 9 13:13:32 2016 |
Gabriele | General | Measurements | Silicon sample |
Silicon wafer from WRS materials, diameter 3", thickness 356-406 microns.
2016-12-09
- 1:00pm, retaining ring and pins installed back, optical system realigned to horizontal reference
- 1:08pm, in chamber, balanced. Since silicon reflection is higher than silica, installed a ND0.3 to avoid QPD saturation
- 1:10pm, roughing pump on
- 1:23pm, turbo pump on
- Excitations
2016-12-12
- Excitation:
- Quiet time before excitation: 1165611248
Broadband excitation
Quiet time after excitation: 1165611382
- Quiet time before excitation: 1165611540
100-1000 Hz excitation
Quiet time after excitation: 1165611619
- 2:05pm, pumps stopped
Results
 
 
% Freq Q Q (C.I. 95%) Q (C.I. 95%)
2043.9 6.5333e+03 6.5061e+03 6.5607e+03
2307.9 1.6958e+04 1.6895e+04 1.7022e+04
3671.0 2.7458e+04 2.7324e+04 2.7595e+04
4909.0 4.1605e+04 4.1322e+04 4.1892e+04
5268.1 2.5236e+04 2.5186e+04 2.5286e+04
6079.0 2.6835e+04 2.6311e+04 2.7382e+04
7317.4 5.1946e+04 5.1799e+04 5.2095e+04
7391.0 1.3702e+04 1.3441e+04 1.3973e+04
8586.6 5.3491e+04 5.2271e+04 5.4769e+04
8719.9 5.4501e+04 5.3904e+04 5.5111e+04
9600.4 6.6514e+04 6.6390e+04 6.6639e+04
9622.1 3.0667e+04 3.0505e+04 3.0830e+04
10507.0 8.1040e+04 8.0965e+04 8.1115e+04
11053.9 6.0651e+04 5.9853e+04 6.1471e+04
11397.5 5.2873e+04 5.2242e+04 5.3520e+04
11950.0 3.2045e+04 3.1514e+04 3.2593e+04
12083.0 8.8181e+04 8.7571e+04 8.8800e+04
12330.6 4.9761e+04 4.8997e+04 5.0549e+04
13799.0 4.8752e+04 4.7609e+04 4.9951e+04
14911.9 8.7301e+04 8.6550e+04 8.8066e+04
15849.6 3.7500e+04 3.6882e+04 3.8139e+04
17381.4 7.5930e+04 7.4582e+04 7.7328e+04
17585.0 9.7947e+04 9.6811e+04 9.9110e+04
17597.0 2.8465e+04 2.7318e+04 2.9712e+04
18310.4 9.0019e+04 8.9175e+04 9.0879e+04
18542.1 6.8287e+04 6.7506e+04 6.9088e+04
18547.5 1.4131e+05 1.4017e+05 1.4248e+05
18774.9 1.0588e+05 1.0490e+05 1.0687e+05
19066.6 8.0216e+04 7.8924e+04 8.1551e+04
20253.5 9.6914e+04 9.4540e+04 9.9411e+04
20463.0 1.0020e+05 9.9323e+04 1.0109e+05
21188.2 1.1931e+05 1.1851e+05 1.2012e+05
21828.5 1.4420e+05 1.4290e+05 1.4552e+05
21837.5 1.5768e+05 1.5639e+05 1.5899e+05
22976.0 5.6472e+04 5.6229e+04 5.6717e+04
23356.5 1.2871e+05 1.2729e+05 1.3017e+05
23398.5 1.4698e+05 1.4422e+05 1.4984e+05
23455.0 1.1209e+05 1.0950e+05 1.1479e+05
23457.7 1.0716e+05 1.0509e+05 1.0932e+05
23496.0 1.4477e+05 1.4295e+05 1.4665e+05
23703.5 1.5954e+05 1.5695e+05 1.6222e+05
23993.0 1.3344e+05 1.3183e+05 1.3510e+05
24758.2 1.4752e+05 1.4655e+05 1.4850e+05
24952.6 1.3025e+05 1.2972e+05 1.3077e+05
25139.0 3.3941e+04 3.3575e+04 3.4316e+04
25298.5 1.0825e+05 1.0603e+05 1.1056e+05
25387.1 1.3101e+05 1.3055e+05 1.3148e+05
25391.7 1.2021e+05 1.2011e+05 1.2032e+05
26752.9 1.0624e+05 1.0595e+05 1.0653e+05
26762.0 1.8838e+05 1.8490e+05 1.9200e+05
26838.0 6.9555e+04 6.7066e+04 7.2237e+04
27147.7 1.0675e+05 1.0571e+05 1.0780e+05
27698.0 8.3204e+04 8.1975e+04 8.4471e+04
28101.4 1.7792e+05 1.7748e+05 1.7836e+05
28109.4 8.9486e+04 8.8527e+04 9.0466e+04
28480.6 1.1985e+05 1.1934e+05 1.2037e+05
28972.0 4.5087e+04 4.3490e+04 4.6806e+04
28979.3 1.3823e+05 1.3750e+05 1.3897e+05
29044.6 1.7261e+05 1.7177e+05 1.7347e+05
29166.4 1.7820e+05 1.7785e+05 1.7855e+05
29222.0 1.8986e+05 1.8640e+05 1.9345e+05
29451.0 3.4557e+04 3.3927e+04 3.5211e+04
30284.4 1.9755e+05 1.9701e+05 1.9810e+05
30691.3 9.7139e+04 9.6728e+04 9.7553e+04
31228.6 1.2060e+05 1.2028e+05 1.2092e+05
32159.5 2.0041e+05 1.9800e+05 2.0288e+05
32226.8 7.3880e+04 7.3119e+04 7.4658e+04
32366.0 2.0220e+05 2.0185e+05 2.0255e+05
|
239
|
Mon Dec 12 08:42:44 2016 |
Gabriele | General | Measurements | Thermoelastic losses in Si sample |
Following the model from R. Nawrodt et al. Investigation of mechanical losses of thin silicon flexures at low temperatures, CQG 30 (2013) 115008, I predicted the thermo-elastic losses in the Si sample. The model matches quite well the measurements:

Here are some details on the model, eq. 1 and 2 of the cited paper:


where:
- alpha = thermal expansion coefficient 2.6e-6/K
- Y = Young's modulus 150 GPa
- T = temperature 300 K
- C_P = specific heat 705 J/kg/K
- rho = density 2329 kg/m^3
- t_f = sample thickness 400 um
- k = thermal conductivity 130 W/m/K
The model is for a cantilever, but it fits well enough for our disk too. |
241
|
Mon Dec 12 16:34:15 2016 |
Gabriele, Brittany, Aaron | General | Measurements | S1600480 |
2016-12-12
- 4:32pm, in chamber, balanced
- 4:33pm, roughing pump on
- 4:46pm, turbo pump on
2016-12-13
- Excitation:
- Quiet time before excitation: 1165689679
Excitation brodband (3 kV, 60s)
Quiet time after excitation: 1165689920
|
245
|
Sat Dec 17 12:20:38 2016 |
Gabriele | General | Measurements | S1600447 after coating (tantala 250 deg. C) |
2016-12-16
- 1:41pm: in chamber, balanced (coating facing up)
- 1:42pm: roughing pump on
- 1:54pm: turbo pump on
- Excitations:
- Quiet time before excitation 1165963531
Broad band excitation (6kV, 60s)
Quiet time after excitation 1165963649
- Quiet time before excitation: 1165964693
Excitation (broad band) at 1165964725 (60 s)
Quiet time after excitation: 1165964787
- Quiet time before excitation: 1165966017
Excitation (broad band) at 1165966050 (60 s)
Quiet time after excitation: 1165966112
- Quiet time before excitation: 1165967342
Excitation (broad band) at 1165967375 (60 s)
Quiet time after excitation: 1165967437
2016-12-17
|
246
|
Sat Dec 17 13:06:06 2016 |
Gabriele | General | Measurements | S1600457 after coating (tantala RT) |
2016-12-17
- 12:54pm, in chamber, balanced. Added a ND0.3 to avoid QPD saturation
- 12:55pm, roughing pump on
- 1:05pm: turbo pump on
- Excitations:
-
Quiet time before excitation: 1166054813
Excitation (broad band) at 1166054845 (60 s)
Quiet time after excitation: 1166054907
-
Quiet time before excitation: 1166056137
Excitation (broad band) at 1166056170 (60 s)
Quiet time after excitation: 1166056232
-
Quiet time before excitation: 1166057463
Excitation (broad band) at 1166057495 (60 s)
Quiet time after excitation: 1166057557
-
Quiet time before excitation: 1166060112
Excitation (broad band) at 1166060144 (60 s)
Quiet time after excitation: 1166060206
2016-12-18
|
247
|
Sun Dec 18 14:42:22 2016 |
Gabriele | General | Measurements | S1600456 after coating (tantala 250 deg. C) |
2016-12-18
- 2:29pm, in chamber, balanced
- 2:30pm, roughing pump on
- 2:42pm, turbo pump on
- Excitations:
-
Quiet time before excitation: 1166146273
Excitation (broad band) at 1166146305 (60 s)
Quiet time after excitation: 1166146367
X3:CR1-AUTOCENTER => 1
-
Quiet time before excitation: 1166147597
Excitation (broad band) at 1166147630 (60 s)
Quiet time after excitation: 1166147692
-
Quiet time before excitation: 1166148922
Excitation (broad band) at 1166148954 (60 s)
Quiet time after excitation: 1166149016
-
Quiet time before excitation: 1166150246
Excitation (broad band) at 1166150278 (60 s)
Quiet time after excitation: 1166150340
-
Quiet time before excitation: 1166151570
Excitation (broad band) at 1166151603 (60 s)
Quiet time after excitation: 1166151665
2016-12-19
|
248
|
Mon Dec 19 10:29:09 2016 |
Gabriele | General | Measurements | S1600458 after coating (tantala RT) |
2016-12-19
- 10:27am: in chamber, balanced
- 10:28am, roughing pump on
- 10:40am, turbo pump on
- Excitations:
-
Quiet time before excitation: 1166214597
Excitation (broad band) at 1166214629 (60 s)
Quiet time after excitation: 1166214691
-
Quiet time before excitation: 1166215921
Excitation (broad band) at 1166215954 (60 s)
Quiet time after excitation: 1166216016
-
Quiet time before excitation: 1166217246
Excitation (broad band) at 1166217278 (60 s)
Quiet time after excitation: 1166217340
-
Quiet time before excitation: 1166218570
Excitation (broad band) at 1166218603 (60 s)
Quiet time after excitation: 1166218665
-
Quiet time before excitation: 1166219895
Excitation (broad band) at 1166219927 (60 s)
Quiet time after excitation: 1166219989
-
More excitations
-
Quiet time before excitation: 1166227570
Excitation (broad band) at 1166227602 (120 s)
Quiet time after excitation: 1166227724
-
Quiet time before excitation: 1166228954
Excitation (broad band) at 1166228987 (120 s)
Quiet time after excitation: 1166229108
-
Quiet time before excitation: 1166230338
Excitation (broad band) at 1166230371 (120 s)
Quiet time after excitation: 1166230493
-
Quiet time before excitation: 1166231723
Excitation (broad band) at 1166231755 (120 s)
Quiet time after excitation: 1166231877
-
Quiet time before excitation: 1166233107
Excitation (broad band) at 1166233139 (120 s)
Quiet time after excitation: 1166233261
2016-12-20
|
249
|
Tue Dec 20 10:00:38 2016 |
Gabriele | General | Measurements | S1600463 control sample |
2016-12-20
- 9:58am, in chamber, balanced. Removed ND0.3
- 10:00am, roughing pump on
- 10:12am, turbo pump on
- Excitations:
-
Quiet time before excitation: 1166299404
Excitation (broad band) at 1166299436 (120 s)
Quiet time after excitation: 1166299558
-
Quiet time before excitation: 1166306789
Excitation (broad band) at 1166306821 (120 s)
Quiet time after excitation: 1166306943
-
3:08pm, pumps off
Here's a comparison of the measured Q values before and after being shipped to Montreal and back. No significant differences.

|
250
|
Tue Dec 20 15:52:12 2016 |
Gabriele | General | Measurements | S1600447 after cleaning |
2016-12-20
- 3:50pm, in chamber, balanced. ND0.3 installed back
- 3:51pm, roughing pump on
- 4:02pm, turbo pump on
- Excitations:
-
Quiet time before excitation: 1166324097
Excitation (broad band) at 1166324129 (120 s)
Quiet time after excitation: 1166324251
-
Quiet time before excitation: 1166325481
Excitation (broad band) at 1166325513 (120 s)
Quiet time after excitation: 1166325635
-
Quiet time before excitation: 1166326865
Excitation (broad band) at 1166326897 (120 s)
Quiet time after excitation: 1166327019
-
Quiet time before excitation: 1166328249
Excitation (broad band) at 1166328282 (120 s)
Quiet time after excitation: 1166328404
-
Quiet time before excitation: 1166329634
Excitation (broad band) at 1166329666 (120 s)
Quiet time after excitation: 1166329788
-
8:45pm, air filters off
-
More excitations:
-
Quiet time before excitation: 1166331404
Excitation (broad band) at 1166331436 (120 s)
Quiet time after excitation: 1166331558
-
Quiet time before excitation: 1166332788
Excitation (broad band) at 1166332820 (120 s)
Quiet time after excitation: 1166332942
-
Quiet time before excitation: 1166334172
Excitation (broad band) at 1166334204 (120 s)
Quiet time after excitation: 1166334326
-
Quiet time before excitation: 1166335556
Excitation (broad band) at 1166335589 (120 s)
Quiet time after excitation: 1166335711
-
Quiet time before excitation: 1166336941
Excitation (broad band) at 1166336973 (120 s)
Quiet time after excitation: 1166337095
2016-12-21
- 7:55am, pumps off
- 8:08am, air filters on
|
251
|
Wed Dec 21 09:00:00 2016 |
Gabriele | General | Measurements | S1600456 after cleaning |
2016-12-21
- 8:59am, in chamber, balanced
- 9:00am, roughing pump on
- 9:11am, turbo pump on
- Excitations:
-
Quiet time before excitation: 1166383869
Excitation (broad band) at 1166383902 (120 s)
Quiet time after excitation: 1166384024
-
Quiet time before excitation: 1166384954
Excitation (broad band) at 1166384986 (120 s)
Quiet time after excitation: 1166385108
-
Quiet time before excitation: 1166386038
Excitation (broad band) at 1166386070 (120 s)
Quiet time after excitation: 1166386192
-
Quiet time before excitation: 1166387123
Excitation (broad band) at 1166387155 (120 s)
Quiet time after excitation: 1166387277
-
Quiet time before excitation: 1166388207
Excitation (broad band) at 1166388239 (120 s)
Quiet time after excitation: 1166388361
-
1:15pm, pumps off
|
252
|
Wed Dec 21 14:32:41 2016 |
Gabriele | General | Measurements | S1600457 after cleaning |
2016-12-21
- 2:22pm, in chamber, balanced
- 2:23pm, roughing pump on
- 2:33pm, turbo pump on
- 5:00pm, clean air filters off
- Excitations:
-
Quiet time before excitation: 1166403765
Excitation (broad band) at 1166403798 (120 s)
Quiet time after excitation: 1166403920
-
Quiet time before excitation: 1166404850
Excitation (broad band) at 1166404882 (120 s)
Quiet time after excitation: 1166405004
-
Quiet time before excitation: 1166405934
Excitation (broad band) at 1166405966 (120 s)
Quiet time after excitation: 1166406088
-
Quiet time before excitation: 1166407018
Excitation (broad band) at 1166407050 (120 s)
Quiet time after excitation: 1166407172
-
Quiet time before excitation: 1166408103
Excitation (broad band) at 1166408136 (120 s)
Quiet time after excitation: 1166408258
2016-12-22
|
253
|
Thu Dec 22 09:47:58 2016 |
Gabriele | General | Measurements | S1600458 after cleaning |
2012-12-22
- 9:46am, in chamber, balanced, removed ND0.3
- 9:48am, roughing pump on
- 9:59am turbo pump on
- Excitations:
-
Quiet time before excitation: 1166473512
Excitation (broad band) at 1166473544 (60 s)
Quiet time after excitation: 1166473606
-
Quiet time before excitation: 1166474536
Excitation (broad band) at 1166474568 (60 s)
Quiet time after excitation: 1166474630
-
Quiet time before excitation: 1166475561
Excitation (broad band) at 1166475593 (60 s)
Quiet time after excitation: 1166475655
-
Quiet time before excitation: 1166476585
Excitation (broad band) at 1166476618 (60 s)
Quiet time after excitation: 1166476680
- Another excitation with HF boost (zeros 2x2000Hz / poles 2x5000Hz)
- Quiet time before excitation: 1166477610
Excitation (broad band) at 1166477642 (60 s)
Quiet time after excitation: 1166477704
2016-12-27
- Excitations:
-
Quiet time before excitation: 1166897529
Excitation (broad band) at 1166897561 (60 s)
Quiet time after excitation: 1166897623
-
Quiet time before excitation: 1166898553
Excitation (broad band) at 1166898585 (60 s)
Quiet time after excitation: 1166898647
-
Quiet time before excitation: 1166899577
Excitation (broad band) at 1166899609 (60 s)
Quiet time after excitation: 1166899671
-
Quiet time before excitation: 1166900601
Excitation (broad band) at 1166900633 (60 s)
Quiet time after excitation: 1166900695
-
Quiet time before excitation: 1166901625
Excitation (broad band) at 1166901658 (60 s)
Quiet time after excitation: 1166901720
2017-01-03
- Quiet time before excitation: 1167513943
Excitation (broad band) at 1167513975 (60 s)
Quiet time after excitation: 1167514037
- Quiet time before excitation: 1167514967
Excitation (broad band) at 1167515000 (60 s)
Quiet time after excitation: 1167515062
- Quiet time before excitation: 1167515992
Excitation (broad band) at 1167516025 (60 s)
Quiet time after excitation: 1167516087
- Quiet time before excitation: 1167517017
Excitation (broad band) at 1167517050 (60 s)
Quiet time after excitation: 1167517112
- Quiet time before excitation: 1167518042
Excitation (broad band) at 1167518074 (60 s)
Quiet time after excitation: 1167518136
2017-01-05
- 11:30am, sample removed from chamber
|
255
|
Fri Jan 6 11:23:10 2017 |
Gabriele | General | Measurements | Mark Optics 4 |
This is one of the samples we got from the first batch, no flats, edge not polished
2017-01-06
- 11:10am, in chamber, balanced
- 11:11am, roughing pump on
- 11:23am, turbo pump on
- Excitations:
- Quiet time after excitation 1167770663
-
Quiet time before excitation: 1167781499
Excitation (broad band) at 1167781532 (60 s)
Quiet time after excitation: 1167781594
-
Quiet time before excitation: 1167792424
Excitation (broad band) at 1167792457 (60 s)
Quiet time after excitation: 1167792519
-
Quiet time before excitation: 1167803349
Excitation (broad band) at 1167803381 (60 s)
Quiet time after excitation: 1167803443
-
Quiet time before excitation: 1167814274
Excitation (broad band) at 1167814306 (60 s)
Quiet time after excitation: 1167814368
2017-01-10
Results
2017-01-06A

2017-01_06B

2017-01-06C

2017-01-06D

|
257
|
Tue Jan 10 11:29:23 2017 |
Gabriele | General | Measurements | S1600459 post deposition |
Note:Coated with tantala at 400C
2017-01-10
- 11:15am in chamber, balanced, added ND0.3 to reduce power on QPD and avoid saturation (got 195 uW total)
- 11:16am roughing pump on
- 11:29am turbo pump on
- Excitations
-
Quiet time before excitation: 1168122715
Excitation (broad band) at 1168122748 (60 s)
Quiet time after excitation: 1168122810
-
Quiet time before excitation: 1168124040
Excitation (broad band) at 1168124072 (60 s)
Quiet time after excitation: 1168124134
-
Quiet time before excitation: 1168125364
Excitation (broad band) at 1168125397 (60 s)
Quiet time after excitation: 1168125459
-
Quiet time before excitation: 1168126689
Excitation (broad band) at 1168126721 (60 s)
Quiet time after excitation: 1168126783
-
Quiet time before excitation: 1168128013
Excitation (broad band) at 1168128045 (60 s)
Quiet time after excitation: 1168128107
-
Quiet time before excitation: 1168129337
Excitation (broad band) at 1168129369 (60 s)
Quiet time after excitation: 1168129431
|
258
|
Tue Jan 10 16:50:20 2017 |
Gabriele | General | Measurements | S1600461 post deposition |
Note:Coated with tantala at 400C
2017-01-10
- 4:48pm, in chamber, balanced
- 4:49pm, roughing pump on
- 5:02pm, turbo pump on
- Excitations
-
Quiet time before excitation: 1168141883
Excitation (broad band) at 1168141915 (60 s)
Quiet time after excitation: 1168141977
-
Quiet time before excitation: 1168145607
Excitation (broad band) at 1168145639 (60 s)
Quiet time after excitation: 1168145701
-
Quiet time before excitation: 1168149331
Excitation (broad band) at 1168149363 (60 s)
Quiet time after excitation: 1168149425
-
Quiet time before excitation: 1168153055
Excitation (broad band) at 1168153088 (60 s)
Quiet time after excitation: 1168153150
-
Quiet time before excitation: 1168156780
Excitation (broad band) at 1168156813 (60 s)
Quiet time after excitation: 1168156875
-
Quiet time before excitation: 1168160505
Excitation (broad band) at 1168160538 (60 s)
Quiet time after excitation: 1168160600
2017-01-11
|
259
|
Wed Jan 11 09:01:59 2017 |
Gabriele | General | Measurements | S1600448 post deposition |
Note: coated with tantala at 480C
2017-01-11
- 9:00am in chamber, balanced
- 9:01am, roughing pump on
- 9:12am turbo pump on
- Excitations:
- Quiet time before excitation: 1168213704
Excitation (broad band) at 1168213737 (60 s)
Quiet time after excitation: 1168213799
- Quiet time before excitation: 1168215629
Excitation (broad band) at 1168215662 (60 s)
Quiet time after excitation: 1168215724
-
Quiet time before excitation: 1168217554
Excitation (broad band) at 1168217586 (60 s)
Quiet time after excitation: 1168217648
-
Quiet time before excitation: 1168219478
Excitation (broad band) at 1168219510 (60 s)
Quiet time after excitation: 1168219572
-
Quiet time before excitation: 1168221402
Excitation (broad band) at 1168221435 (60 s)
Quiet time after excitation: 1168221497
-
Quiet time before excitation: 1168223327
Excitation (broad band) at 1168223359 (60 s)
Quiet time after excitation: 1168223421
2017-01-12
|
260
|
Thu Jan 12 10:09:41 2017 |
Gabriele | General | Measurements | S1600453 post deposition |
Note: coated with tantala at 480 C
2017-01-12
- 10:07am in chamber, balanced
- 10:09am, roughing pump on
- 10:22am, turbo pump on
- Excitations:
-
Quiet time before excitation: 1168291819
Excitation (broad band) at 1168291851 (60 s)
Quiet time after excitation: 1168291913
-
Quiet time before excitation: 1168293743
Excitation (broad band) at 1168293775 (60 s)
Quiet time after excitation: 1168293838
-
Quiet time before excitation: 1168295668
Excitation (broad band) at 1168295701 (60 s)
Quiet time after excitation: 1168295763
-
Quiet time before excitation: 1168297593
Excitation (broad band) at 1168297625 (60 s)
Quiet time after excitation: 1168297687
-
Quiet time before excitation: 1168299517
Excitation (broad band) at 1168299549 (60 s)
Quiet time after excitation: 1168299611
-
Quiet time before excitation: 1168301442
Excitation (broad band) at 1168301474 (60 s)
Quiet time after excitation: 1168301536
- More excitations:
-
Quiet time before excitation: 1168314406
Excitation (broad band) at 1168314438 (60 s)
Quiet time after excitation: 1168314500
-
Quiet time before excitation: 1168316330
Excitation (broad band) at 1168316362 (60 s)
Quiet time after excitation: 1168316424
-
Quiet time before excitation: 1168318254
Excitation (broad band) at 1168318287 (60 s)
Quiet time after excitation: 1168318349
-
Quiet time before excitation: 1168320179
Excitation (broad band) at 1168320212 (60 s)
Quiet time after excitation: 1168320274
-
Quiet time before excitation: 1168322104
Excitation (broad band) at 1168322136 (60 s)
Quiet time after excitation: 1168322198
-
Quiet time before excitation: 1168324028
Excitation (broad band) at 1168324060 (60 s)
Quiet time after excitation: 1168324122
2017-01-13
|
262
|
Wed Jan 18 14:02:56 2017 |
Gabriele | General | Measurements | S1600466 control sample |
2017-01-18
- 2:01pm, in chamber, balanced, removed ND
- 2:02pm, roughing pump on
- 2:14pm, turbo pump on
- Excitations:
-
Quiet time before excitation: 1168833851
Excitation (broad band) at 1168833883 (60 s)
Quiet time after excitation: 1168833945
-
Quiet time before excitation: 1168844775
Excitation (broad band) at 1168844808 (60 s)
Quiet time after excitation: 1168844870
-
Quiet time before excitation: 1168855700
Excitation (broad band) at 1168855732 (60 s)
Quiet time after excitation: 1168855794
2017-01-19
Results
The plot below compare the measured Q before and after the sample was sent to Montreal. The Q values measured after are systematically lower. According to the notes received from the Montreal group, this sample has been through quite many things, see below.


|
Attachment 2: Screen_Shot_2017-01-19_at_9.33.33_AM.png
|
|
268
|
Fri Jan 20 11:24:39 2017 |
Gabriele | General | Measurements | S1600489 |
2017-01-20
- 10:58am, in chamber, balanced
- 10:59am, roughing pump on
- 11:24, turbo on
- Excitations
-
Quiet time before excitation: 1168999600
Excitation (broad band) at 1168999633 (60 s)
Quiet time after excitation: 1168999695
-
Quiet time before excitation: 1169010525
Excitation (broad band) at 1169010557 (60 s)
Quiet time after excitation: 1169010619
-
Quiet time before excitation: 1169021449
Excitation (broad band) at 1169021482 (60 s)
Quiet time after excitation: 1169021544
-
Quiet time before excitation: 1169032374
Excitation (broad band) at 1169032406 (60 s)
Quiet time after excitation: 1169032468
2017-01-21
|
271
|
Sat Jan 21 15:55:04 2017 |
Gabriele | General | Measurements | S1600490 |
2017-01-21
- 3:43pm, in chamber, balanced
- 3:44pm, roughing pump on
- 3:55pm turbo pump on
- Excitations:
-
Quiet time before excitation: 1169095612
Excitation (broad band) at 1169095644 (60 s)
Quiet time after excitation: 1169095706
-
Quiet time before excitation: 1169106536
Excitation (broad band) at 1169106568 (60 s)
Quiet time after excitation: 1169106630
-
Quiet time before excitation: 1169117460
Excitation (broad band) at 1169117492 (60 s)
Quiet time after excitation: 1169117554
-
Quiet time before excitation: 1169128385
Excitation (broad band) at 1169128417 (60 s)
Quiet time after excitation: 1169128479
2017-01-23
|
273
|
Mon Jan 23 17:04:47 2017 |
Gabriele | General | Measurements | S1600491 |
2017-01-23
- 4:51pm in chamber, balanced
- 4:52pm, roughing pump on
- 4:54pm, turbo pump on
- Excitations
-
Quiet time before excitation: 1169273022
Excitation (broad band) at 1169273054 (60 s)
Quiet time after excitation: 1169273116
-
Quiet time before excitation: 1169283946
Excitation (broad band) at 1169283978 (60 s)
Quiet time after excitation: 1169284040
-
Quiet time before excitation: 1169294870
Excitation (broad band) at 1169294902 (60 s)
Quiet time after excitation: 1169294964
-
Quiet time before excitation: 1169305794
Excitation (broad band) at 1169305827 (60 s)
Quiet time after excitation: 1169305889
2017-01-24
|
274
|
Tue Jan 24 11:01:58 2017 |
Gabriele | General | Measurements | S1600492 |
2017-01-24
- 11:00am, in chamber, balanced
- 11:02am, roughing pump on
- 11:13am, turbo pump on
- Excitations
-
Quiet time before excitation: 1169335400
Excitation (broad band) at 1169335432 (60 s)
Quiet time after excitation: 1169335494
-
Quiet time before excitation: 1169346908
Excitation (broad band) at 1169346940 (60 s)
Quiet time after excitation: 1169347002
-
Quiet time before excitation: 1169357832
Excitation (broad band) at 1169357864 (60 s)
Quiet time after excitation: 1169357926
-
Quiet time before excitation: 1169368756
Excitation (broad band) at 1169368788 (60 s)
Quiet time after excitation: 1169368850
-
Quiet time before excitation: 1169379680
Excitation (broad band) at 1169379713 (60 s)
Quiet time after excitation: 1169379775
2017-01-25
|
279
|
Fri Jan 27 10:40:03 2017 |
Gabriele | General | Measurements | S1600493 |
2017-01-27
- 10:38am, in chamber, balanced
- 10:39am, roughing pump on
- 10:53am, turbo pump on
- Excitations:
-
Quiet time before excitation: 1169592263
Excitation (broad band) at 1169592295 (60 s)
Quiet time after excitation: 1169592357
-
Quiet time before excitation: 1169603187
Excitation (broad band) at 1169603219 (60 s)
Quiet time after excitation: 1169603281
-
Quiet time before excitation: 1169614111
Excitation (broad band) at 1169614143 (60 s)
Quiet time after excitation: 1169614205
-
Quiet time before excitation: 1169625035
Excitation (broad band) at 1169625067 (60 s)
Quiet time after excitation: 1169625129
-
Quiet time before excitation: 1169664828
Excitation (broad band) at 1169664861 (60 s)
Quiet time after excitation: 1169664923
2017-01-28
|
281
|
Sat Jan 28 15:39:30 2017 |
Gabriele | General | Measurements | S1600494 |
2017-01-28
- 3:38pm, in chamber, balanced
- 3:39pm, roughing pump on
- 3:50pm, turbo pump on
- Excitations
-
Quiet time before excitation: 1169700428
Excitation (broad band) at 1169700460 (60 s)
Quiet time after excitation: 1169700522
-
Quiet time before excitation: 1169711352
Excitation (broad band) at 1169711384 (60 s)
Quiet time after excitation: 1169711446
-
Quiet time before excitation: 1169722276
Excitation (broad band) at 1169722308 (60 s)
Quiet time after excitation: 1169722370
-
Quiet time before excitation: 1169733200
Excitation (broad band) at 1169733232 (60 s)
Quiet time after excitation: 1169733294
-
Quiet time before excitation: 1169744124
Excitation (broad band) at 1169744156 (60 s)
Quiet time after excitation: 1169744218
-
Quiet time before excitation: 1169755048
Excitation (broad band) at 1169755080 (60 s)
Quiet time after excitation: 1169755142
2017-01-30
|
290
|
Mon Feb 6 08:37:54 2017 |
Gabriele | General | Measurements | S1600495 |
2017-02-06
- 8:35am in chamber, balanced
- 8:36am roughing pump on
- 8:50am tubo pump on
- Excitations: (they didn't work, I forgot to switch on the noise!!)
-
Quiet time before excitation: 1170460053
Excitation (broad band) at 1170460085 (60 s)
Quiet time after excitation: 1170460147
-
Quiet time before excitation: 1170470977
Excitation (broad band) at 1170471010 (60 s)
Quiet time after excitation: 1170471072
-
Quiet time before excitation: 1170481902
Excitation (broad band) at 1170481935 (60 s)
Quiet time after excitation: 1170481997
-
Quiet time before excitation: 1170492827
Excitation (broad band) at 1170492860 (60 s)
Quiet time after excitation: 1170492922
-
Quiet time before excitation: 1170503752
Excitation (broad band) at 1170503785 (60 s)
Quiet time after excitation: 1170503847
-
Quiet time before excitation: 1170514677
Excitation (broad band) at 1170514710 (60 s)
Quiet time after excitation: 1170514772
2017-02-07
|
292
|
Mon Feb 6 14:09:07 2017 |
Gabriele | General | Measurements | First set of parallel measurements completed |
The new laser is still acting up a bit, with a wandering line moving sometimes inside the band. Nevertheless, I could perform the first complete measurement of four samples in parallel.
Everything went as expected, there is no visible cross coupling between modes of different disks. The MATLAB code for the analysis is ready and working.
Here are the results:
 
 
|
Attachment 1: results_06-Feb-2017.png
|
|
293
|
Mon Feb 6 16:22:47 2017 |
Gabriele | General | Measurements | S1600472 S1600478 S1600473 S1600480 |
- In the new chamber
- Excitations:
-
Quiet time before excitation: 1170443490
Excitation (broad band) at 1170443523 (60 s)
Quiet time after excitation: 1170443586
-
Quiet time before excitation: 1170454416
Excitation (broad band) at 1170454449 (60 s)
Quiet time after excitation: 1170454512
-
Quiet time before excitation: 1170465342
Excitation (broad band) at 1170465375 (60 s)
Quiet time after excitation: 1170465438
2017-02-07
- 9:36am gate valve closed, pumps off
|
294
|
Tue Feb 7 10:03:35 2017 |
Gabriele | General | Measurements | S1600496 |
2017-02-07
- 10:02am in chamber, balanced
- 10:03am roughing pump on
- 10:30am turbo pump on
- Excitations (they didn't work, I forgot to switch on the noise!!)
-
Quiet time before excitation: 1170548335
Excitation (broad band) at 1170548367 (60 s)
Quiet time after excitation: 1170548429
-
Quiet time before excitation: 1170559259
Excitation (broad band) at 1170559291 (60 s)
Quiet time after excitation: 1170559353
-
Quiet time before excitation: 1170570183
Excitation (broad band) at 1170570216 (60 s)
Quiet time after excitation: 1170570278
-
Quiet time before excitation: 1170581108
Excitation (broad band) at 1170581140 (60 s)
Quiet time after excitation: 1170581202
-
Quiet time before excitation: 1170592032
Excitation (broad band) at 1170592064 (60 s)
Quiet time after excitation: 1170592126
-
Quiet time before excitation: 1170602956
Excitation (broad band) at 1170602989 (60 s)
Quiet time after excitation: 1170603051
-
Excitations:
-
Quiet time before excitation: 1170638328
Excitation (broad band) at 1170638360 (60 s)
Quiet time after excitation: 1170638422
-
Quiet time before excitation: 1170649252
Excitation (broad band) at 1170649285 (60 s)
Quiet time after excitation: 1170649347
-
Quiet time before excitation: 1170660177
Excitation (broad band) at 1170660209 (60 s)
Quiet time after excitation: 1170660271
-
Quiet time before excitation: 1170671101
Excitation (broad band) at 1170671133 (60 s)
Quiet time after excitation: 1170671195
-
Quiet time before excitation: 1170682025
Excitation (broad band) at 1170682057 (60 s)
Quiet time after excitation: 1170682119
2017-02-09
|