40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Coating Ring-down Measurement Lab elog, Page 1 of 18  Not logged in ELOG logo
Entry  Thu Jul 28 13:58:48 2016, Alena, Gabriele, Clean, Daily Progress, The old chamber is now being cleaned and baked 20160728_092350.jpg
Entry  Tue Aug 16 11:53:30 2016, Alena, Gabriele, Clean, Daily Progress, Clean room progress 2016-08-16_10.25.05.jpg
Entry  Wed Aug 17 16:41:05 2016, Gabriele, Alena, Clean, Daily Progress, Clean room construction progress 2016-08-17_15.29.40.jpg2016-08-17_15.30.05.jpg
Entry  Thu Aug 18 18:15:18 2016, Gabriele, Alena, Clean, Daily Progress, Clean room construction progress 2016-08-18_18.07.29.jpg2016-08-18_18.07.42.jpg
Entry  Thu Oct 20 14:38:24 2016, Gabriele, Clean, Daily Progress, Cleaning of S1600433 and S1600438 
Entry  Mon May 13 18:37:47 2019, aaron, Clean, General, Clean room gear 
    Reply  Mon May 20 10:35:45 2019, aaron, Clean, General, Clean room gear 
Entry  Fri May 6 14:20:43 2016, Gabriele, Electronics, Design, Design of optical lever electronics  qpd.PDFBreakout.PDF
    Reply  Sun May 8 13:35:04 2016, rana, Electronics, Design, Design of optical lever electronics  
    Reply  Tue May 10 13:32:17 2016, Gabriele, Electronics, Design, Design of optical lever electronics  
Entry  Thu May 19 11:33:44 2016, Gabriele, Electronics, Design, Optical lever electronics design 
Entry  Thu May 26 02:51:27 2016, Gabriele, Electronics, Design, ESD design 
Entry  Mon Jun 6 13:35:36 2016, Gabriele, Electronics, General, Components 2016-06-06_13.29.01.jpg
Entry  Fri Jun 10 13:44:06 2016, Gabriele, Electronics, Configuration, How to setup a workstation 
Entry  Fri Jun 24 17:03:47 2016, Gabriele, Electronics, Daily Progress, QPD electronics 2016-06-24_16.31.48.jpg2016-06-24_16.31.52.jpg
    Reply  Tue Jun 28 10:17:28 2016, Gabriele, Electronics, Daily Progress, QPD electronics 
Entry  Thu Jun 30 16:18:28 2016, Gabriele, Electronics, Daily Progress, QPD electronics is working 
Entry  Thu Jun 30 17:23:54 2016, Gabriele, Electronics, Daily Progress, Cymac 2016-06-30_11.08.31.jpg
Entry  Fri Jul 1 15:12:12 2016, Gabriele, Electronics, Daily Progress, QPD electronics noise qpd_noise.pngqpd_noise_m.png2016-07-01_15.12.44.jpg
Entry  Thu Jul 7 16:40:22 2016, Gabriele , Electronics, Daily Progress, QPD boxes 2016-07-07_15.55.06.jpg
Entry  Fri Jul 8 16:49:11 2016, Gabriele, Electronics, Configuration, CyMAC  Screen_Shot_2016-07-08_at_4.38.16_PM.png
Entry  Mon Jul 11 08:49:25 2016, Gabriele, Electronics, Configuration, Cymac RTS configuration 
Entry  Tue Jul 12 17:19:07 2016, Gabriele, Electronics, Daily Progress, ADC and DAC cabling 2016-07-12_15.57.17.jpg2016-07-12_16.59.17.jpg2016-07-12_16.59.13.jpg
    Reply  Thu Jul 14 15:30:48 2016, ericq, Electronics, Configuration, Cymac RTS configuration 
Entry  Thu Jul 14 17:06:47 2016, Gabriele, Electronics, Configuration, Networking 
Entry  Fri Jul 15 16:05:07 2016, Gabriele, Electronics, Daily Progress, Electrostatic actuator installed 2016-07-15_15.02.29.jpg2016-07-15_15.02.56.jpg2016-07-15_15.03.03.jpg2016-07-15_15.03.09.jpg
Entry  Mon Jul 18 13:42:46 2016, Gabriele, Electronics, Characterization, QPD signal convention qpd.png.pngScreenshot-Untitled_Window.png
Entry  Mon Jul 18 17:48:58 2016, Gabriele, Electronics, Configuration, Status of real time system and workstation 
Entry  Tue Jul 19 20:19:38 2016, Gabriele, Electronics, Configuration, Glitches are a digital artifact glitches.pngglitches.pngjump1.pngjump2.png
    Reply  Wed Jul 20 10:26:40 2016, Gabriele, Electronics, Configuration, Are glitches a digital artifact? 
Entry  Thu Jul 21 14:58:26 2016, Gabriele, Electronics, General, Glitches are of digital origin glitches_hene_table.pngglitch_hene_table_2.png
Entry  Fri Jul 22 14:22:10 2016, Gabriele, Electronics, Configuration, Investigations on the signal jumps glithces.pngglitch2.png
Entry  Mon Jul 25 12:24:06 2016, Gabriele, Electronics, Configuration, More on the signal jumps no_glitches_on_cymac2_b.pngno_glitches_on_cymac2.png
Entry  Mon Jul 25 17:44:13 2016, Gabriele, Electronics, Characterization, High frequency noise budget qpd_noises.pngqpd_noise_budget.png
    Reply  Tue Jul 26 11:45:03 2016, Gabriele, Electronics, Characterization, High frequency noise budget noise_budget.pngnoise_budget.pngnoise_budget_whitened.png
Entry  Wed Jul 27 08:59:12 2016, Gabriele, Electronics, General, Pressure now in torr pressure.png
Entry  Wed Jul 27 10:19:36 2016, Gabriele, Electronics, Configuration, Last finding in the signal jump saga glitch_with_all_digital_signal.pngpmt_cymac3.pngpmt_cymac2.png
Entry  Thu Jul 28 17:15:22 2016, Gabriele, Electronics, Daily Progress, ADC/DAC interfaces upgrade 2016-07-28_17.02.46.jpg2016-07-28_17.03.11.jpg
Entry  Mon Aug 1 16:56:57 2016, Gabriele, Electronics, Daily Progress, Populated four new QPD boards 
Entry  Tue Aug 2 15:58:12 2016, Gabriele, Electronics, Daily Progress, Six QPD functional and tested 2016-08-02_15.15.43.jpg
Entry  Tue Aug 2 16:00:32 2016, Gabriele, Electronics, Characterization, More on the signal jumps out1.pngout2.pngout3.png
Entry  Wed Aug 10 09:39:38 2016, Gabriele, Electronics, Daily Progress, Annuntio vobis gaudium magnum: habemus Cymac qpd_spectra.png
Entry  Thu Aug 11 09:10:01 2016, Gabriele, Electronics, Configuration, Real time model model1.pngmodel2.pngmain_medm.png
Entry  Thu Aug 11 10:59:39 2016, Gabriele, Electronics, Configuration, Quadrant calibration 
Entry  Fri Aug 12 10:33:14 2016, Gabriele, Electronics, Configuration, Storage added to cymac3 
Entry  Sun Aug 14 11:40:29 2016, Gabriele, Electronics, Daily Progress, Some python code  noise.pngnoise_multi_band.pngpeak.png
Entry  Sun Aug 14 18:13:52 2016, Gabriele, Electronics, Daily Progress, Progress on the user interface crime1.pngcrime2.png
Entry  Tue Aug 16 11:57:03 2016, Gabriele, Electronics, Configuration, Fixed cymac3 network and time issue 
Entry  Thu Sep 22 15:00:49 2016, Gabriele, Electronics, Configuration, Epics values now saved to frames 
    Reply  Fri Sep 23 08:33:39 2016, Gabriele, Electronics, Configuration, Epics values now saved to frames 
ELOG V3.1.3-