67
|
Thu Jul 28 13:58:48 2016 |
Alena, Gabriele | Clean | Daily Progress | The old chamber is now being cleaned and baked | Cleaned the chamber in the washing machine
at 40m and started 48 baking at 120 C |
|
86
|
Tue Aug 16 11:53:30 2016 |
Alena, Gabriele | Clean | Daily Progress | Clean room progress | Some progress on the cleam room: bar fixed
to the wall, some more structure built, filters
in place. We had to (literally) work around |
|
88
|
Wed Aug 17 16:41:05 2016 |
Gabriele, Alena | Clean | Daily Progress | Clean room construction progress | The clean room frame is built and secured
to the floor and wall. Panels are being installed
on the ceiling and back. Also, the optical |
 |
89
|
Thu Aug 18 18:15:18 2016 |
Gabriele, Alena | Clean | Daily Progress | Clean room construction progress | Ceiling, back and side panels are installed.
The air filters have been cabled and connected
to the power supply. |
 |
140
|
Thu Oct 20 14:38:24 2016 |
Gabriele | Clean | Daily Progress | Cleaning of S1600433 and S1600438 | Samples #433 (annealed and cleaned) and
#438 (as received from Mark Optics) are now
with GariLynn for deep cleaning. |
|
689
|
Mon May 13 18:37:47 2019 |
aaron | Clean | General | Clean room gear | Mon May 13 18:37:37 2019
Entered CRIME lab to borrow 4x
hair nets and face masks. Can you |
|
696
|
Mon May 20 10:35:45 2019 |
aaron | Clean | General | Clean room gear | Aaron,
There is a buy list of approved
clean room supplies posted here https://dcc.ligo.org/LIGO-E1300399. |
|
11
|
Fri May 6 14:20:43 2016 |
Gabriele | Electronics | Design | Design of optical lever electronics | For the optical levers we are going to
use the same QPD that are used in aLIGO optical
levers (see T1600085 and |
 |
12
|
Sun May 8 13:35:04 2016 |
rana | Electronics | Design | Design of optical lever electronics | Koji, Rich, and I recently came up with
a new QPD design which is better for general
lab use than the aLIGO ones (which have a |
|
13
|
Tue May 10 13:32:17 2016 |
Gabriele | Electronics | Design | Design of optical lever electronics | After a very useful discussion with Rich
this morning, I think the circuit based on
aLIGO optical levers design should be good |
|
14
|
Thu May 19 11:33:44 2016 |
Gabriele | Electronics | Design | Optical lever electronics design | The circuit design sent out for fabrication
is available in the DCC: D1600196 |
|
18
|
Thu May 26 02:51:27 2016 |
Gabriele | Electronics | Design | ESD design | A preliminary design of the ESD board is
available on the DCC: D1600214 |
|
20
|
Mon Jun 6 13:35:36 2016 |
Gabriele | Electronics | General | Components | The PCBs for the QPD circuit and ADC interface
are here and look ok. All electronics components
are also here (except for the ADC connector |
|
22
|
Fri Jun 10 13:44:06 2016 |
Gabriele | Electronics | Configuration | How to setup a workstation | Instructions on how to setup a workstation
are available here:
https://nodus.ligo.caltech.edu:8081/Cryo_Lab/1135 |
|
24
|
Fri Jun 24 17:03:47 2016 |
Gabriele | Electronics | Daily Progress | QPD electronics | Between yesterday and today I populated
one QPD board (based on D1600196),
and started testing it. The transimpedance |
 |
25
|
Tue Jun 28 10:17:28 2016 |
Gabriele | Electronics | Daily Progress | QPD electronics | Transimpendance and whitening are working
properly. I can't get useful signal out
of the differential stages yet. I replaced |
|
27
|
Thu Jun 30 16:18:28 2016 |
Gabriele | Electronics | Daily Progress | QPD electronics is working | Today I gave up trying to fix the first
board I populated, and built a second one.
The good news is that it's working as |
|
28
|
Thu Jun 30 17:23:54 2016 |
Gabriele | Electronics | Daily Progress | Cymac | I got two new ADC and DAC boards from Rolf,
with the correct PCIe interface. I installed
them into the cymac and checked that the |
|
29
|
Fri Jul 1 15:12:12 2016 |
Gabriele | Electronics | Daily Progress | QPD electronics noise |
I turned out that all the noise
I was seeing in the QPD spectrum was due |
  |
30
|
Thu Jul 7 16:40:22 2016 |
Gabriele | Electronics | Daily Progress | QPD boxes | To mitigate the issue of ambient light
pulluting the QPD signal, I mounted the prototype
into a custum built box. This helps a lot. |
|
34
|
Fri Jul 8 16:49:11 2016 |
Gabriele | Electronics | Configuration | CyMAC | In the last days Jamie installed the patched
kernel to run the real time system (RTS)
on the new CyMAC. Today (with Jamie's |
|
35
|
Mon Jul 11 08:49:25 2016 |
Gabriele | Electronics | Configuration | Cymac RTS configuration | I copy here parts of an email from Jamie
with instructions on how to run the RTS on
the cymac: |
|
39
|
Tue Jul 12 17:19:07 2016 |
Gabriele | Electronics | Daily Progress | ADC and DAC cabling | This afternoon I completed the assembly
of the electronics boards to interface the
ADC and DAC. The ADC is interfaced with a |
  |
40
|
Thu Jul 14 15:30:48 2016 |
ericq | Electronics | Configuration | Cymac RTS configuration | We played around a bit with the cymac,
in efforts to make things better.
We disabled some more fancy-sounding |
|
42
|
Thu Jul 14 17:06:47 2016 |
Gabriele | Electronics | Configuration | Networking | The laboratory workstation is coatings.ligo.caltech.edu
The RTS is cymac3.ligo.caltech.edu
I set up a ssh-mount of the /opt/rtcds/userapps |
|
43
|
Fri Jul 15 16:05:07 2016 |
Gabriele | Electronics | Daily Progress | Electrostatic actuator installed | Using the already installed high voltage
feedthrough, I cabled one of the electrostatic
actuators (1mm gap between electrodes) and |
   |
47
|
Mon Jul 18 13:42:46 2016 |
Gabriele | Electronics | Characterization | QPD signal convention | The QPD quadrants are wired accoridng to
the following convention
|
 |
50
|
Mon Jul 18 17:48:58 2016 |
Gabriele | Electronics | Configuration | Status of real time system and workstation | [EricQ, Gabriele]
The real time system seems to be
working properly, except for the excitations: |
|
54
|
Tue Jul 19 20:19:38 2016 |
Gabriele | Electronics | Configuration | Glitches are a digital artifact | The glitches I saw in the data happens
roughly every second, even though not
exactly on the second. They are suddend jumps |
   |
55
|
Wed Jul 20 10:26:40 2016 |
Gabriele | Electronics | Configuration | Are glitches a digital artifact? | Not so sure anymore...
those glitches do not happen
at regular times
I tried to send |
|
57
|
Thu Jul 21 14:58:26 2016 |
Gabriele | Electronics | General | Glitches are of digital origin | So here's the final proof that the
glitches I see are digital:
There is a positive jump |
 |
58
|
Fri Jul 22 14:22:10 2016 |
Gabriele | Electronics | Configuration | Investigations on the signal jumps | [Rolf, Ben, Rich, Gabriele]
Rolf couldn't find any good
explanation on the software side for the |
 |
59
|
Mon Jul 25 12:24:06 2016 |
Gabriele | Electronics | Configuration | More on the signal jumps | Here are two more tests I did this morning
removed the DAC card from
the cymac and the models, and restarted everything: |
 |
61
|
Mon Jul 25 17:44:13 2016 |
Gabriele | Electronics | Characterization | High frequency noise budget | I measured the noise sources limiting the
QPD sensitivity. Unfortunately, I had to
do some MATLAB tricks to get rid of the glitches: |
 |
62
|
Tue Jul 26 11:45:03 2016 |
Gabriele | Electronics | Characterization | High frequency noise budget | Just to confirm that my noise estimates
make sense, here's a plot of the not-normalized
QPD signal that gives the X motion (sum and |
  |
63
|
Wed Jul 27 08:59:12 2016 |
Gabriele | Electronics | General | Pressure now in torr | The old channel X3:CR1-PRESSURE_LOGTORR
does not exist anymore. The new channel is
now directly in torr and it is called X3:CR1-PRESSURE_TORR. |
|
64
|
Wed Jul 27 10:19:36 2016 |
Gabriele | Electronics | Configuration | Last finding in the signal jump saga | This plot shows a signal which is generated
purely digitally inside a code that I was
testing. |
  |
69
|
Thu Jul 28 17:15:22 2016 |
Gabriele | Electronics | Daily Progress | ADC/DAC interfaces upgrade | Installed the ADC and DAC boards into a
proper box. Also, swapped the temporary DAC
board (with cale hack) with the final one. |
 |
71
|
Mon Aug 1 16:56:57 2016 |
Gabriele | Electronics | Daily Progress | Populated four new QPD boards | Today I populated four more QPD boards.
All components are installed, except for
the QPD themselves. |
|
72
|
Tue Aug 2 15:58:12 2016 |
Gabriele | Electronics | Daily Progress | Six QPD functional and tested | I finished populating the new four QPD
boards, and fixed the first one I populated
weeks ago. I tested all five new boards: |
|
73
|
Tue Aug 2 16:00:32 2016 |
Gabriele | Electronics | Characterization | More on the signal jumps | So I’m
sending a 1.123 Hz sinusoid into the ADC, |
  |
75
|
Wed Aug 10 09:39:38 2016 |
Gabriele | Electronics | Daily Progress | Annuntio vobis gaudium magnum: habemus Cymac | Yesterday I cloned the cymac2 disk and
installed it into the cymac3.
Jamie tweaked a few things (I can't |
|
78
|
Thu Aug 11 09:10:01 2016 |
Gabriele | Electronics | Configuration | Real time model | Compiled and installed an updated real
time model. It acquires the four QPD segments,
compute sum and differences, and normalize. |
  |
79
|
Thu Aug 11 10:59:39 2016 |
Gabriele | Electronics | Configuration | Quadrant calibration | I cross checked the calibration of the
sum channel with a power meter. Now
all quadnant signals X3:Q?_OUT and the sum |
|
80
|
Fri Aug 12 10:33:14 2016 |
Gabriele | Electronics | Configuration | Storage added to cymac3 | Installed two new 2TB disks into the cymac3.
Also, the main disk has a 1TB partition with
the operating system, so I created a new |
|
83
|
Sun Aug 14 11:40:29 2016 |
Gabriele | Electronics | Daily Progress | Some python code | Today I wrote some auxiliary functions
that will be useful for the measurement system:
noise.py: set of functions |
  |
84
|
Sun Aug 14 18:13:52 2016 |
Gabriele | Electronics | Daily Progress | Progress on the user interface | Some progress on writing the user interface:
|
 |
87
|
Tue Aug 16 11:57:03 2016 |
Gabriele | Electronics | Configuration | Fixed cymac3 network and time issue | The cymac3 internal clock was off by about
10 seconds. When I tried to start the NTP
service, I found out that the cymac3 couldn't |
|
123
|
Thu Sep 22 15:00:49 2016 |
Gabriele | Electronics | Configuration | Epics values now saved to frames | I was looking at some past trend data and
discovered that EPICS values were not written
to the frames. I added the following two |
|
125
|
Fri Sep 23 08:33:39 2016 |
Gabriele | Electronics | Configuration | Epics values now saved to frames | Now EPICS values are saved to frames, but
they are all zero! I noticed that we always
had the same problems with the cymac2 too. |
|