  155   Tue Nov 1 15:34:49 2016 Alena, CalumGeneral Annealing run

Annealing run (449-453) on 3" wafers - Crime 11/01/2016 https://dcc.ligo.org/T1600507

  430   Thu Sep 14 15:59:10 2017 GabrieleFacility All wrapped up for Saturday plumbing work



 

  263   Wed Jan 18 14:29:16 2017 AlenaGeneralAnnealingAnnealing run (489-490) on 3" wafers - Crime 01/18/2017


Started annealing run Annealing run (489-490) on 3" wafers - Crime 01/18/2017 https://dcc.ligo.org/T1700027 using new hardware

 

  269   Fri Jan 20 16:00:36 2017 AlenaGeneralAnnealingAnnealing run (491-496) on 3" wafers - Crime 01/20/2017

 Started Annealing run (491-496) on 3" wafers - Crime 01/20/2017 https://dcc.ligo.org/LIGO-T1700036 Will be done by Monday

  350   Wed Jun 21 17:04:20 2017 AlenaGeneralAnnealingAnnealing run (541-542) on 3" wafers - Crime 06/25/2017

Started an annealing run https://dcc.ligo.org/LIGO-T1700271

Will be ready by Friday morning

 

  355   Tue Jun 27 09:20:16 2017 AlenaGeneralAnnealingAnnealing run (546-551) on 3" wafers - Crime 06/27/2017

Started annealing run https://dcc.ligo.org/T1700293

Will be ready by June 28th afternoon

  453   Thu Jan 25 15:33:51 2018 Gabriele, BenGeneralAnnealingAnnealing of 50mm disks

Annealing of 8 fused silica substrates (50mm/0.5mm) started at 3:30pm, January 25th 2018. Standard program: 9 hours ramp up to 900 C, 9 hours hold, 9 hours ramp down

  1   Wed Jul 11 23:01:01 2012 janoschOpticsCharacterizationstarting the multi-color scatter experiment

Steve Maloney, a visiting highschool teacher, and I have started to set up a new scattering experiment in the Richter lab. The idea is to take images of large-angle scattered light using different lasers. We have one 633nm laser, and 532nm and 405nm laser pointers. The goal is to uniformly illuminate the same disk of about 1cm diameter on a silver-coated mirror with all three colors. We use a silver-coated mirror to make sure that the light is reflected from the same layer so that all colors are scattered from the same abberations.

DSCF3148.JPG

The image shows one of the laser pointers and the HeNe laser. The first step is to widen the beam with a f=5cm broadband, AR coated lens (Newport PAC15AR.15). The diverging beam is then aligned through an iris to give it the right size on the mirror. In this way, illumination is almost uniform on the mirror surface.

DSCF3151.JPGDSCF3150.JPG

The mirror is mounted over the rotation axis of a unipolar stepper motor. For the moment we only took images from fixed direction (initially with a commercial digital camera, later with a monochromatic Sony XT-ST50 CCD camera. The problem with the commercial camera was that you cannot completely control what the camera is doing. Also it would have been very difficult to calibrate the image once you start comparing scattering with different colors. A f=7.5cm lens is used to image the illuminated disk on the CCD chip to make maximal use of its resolution. The CCD signal is read out on a Windows machine with an EasyCap video capture device connected to a USB port. Standard software can then be used to take images or record videos. For some reason the capture device reduces the image size to 640x480 pixels (a little less than the size of the CCD chip).

Eventually the camera and lens will be mounted on a metal arm whose orientation is controlled by the stepper motor. The stepper motor was part of the Silicon Motor Reference Design (Silicon Laboratories). It comes with all kinds of cables and a motor control board. Software is provided to upload compiled C code to the board, but for our purposes it is easiest to use primitive communication methods between the PC and the board. We are working with HyperTerminal that used to be part of Windows installations, but now it has to be downloaded from the web. This program can send simple commands through TCP/IP and COM ports. These commands allow us to position the motor and define its rotation speed. Since our PC does not have a serial port, we purchased a Belkin USB Serial Adapter. You will have to search the web to find suitable drivers for Windows 7 x64. Luckily, Magic Control Technology has similar products and the driver for their U232-P9 USB/serial adapter also works for the Belkin product.

So our goal for the remaining weeks is to take many images from various angles and to set up the experiment in a way that we can VNC into our lab PC and control everything from the Red Door Cafe.

 

 

  2   Fri Jul 13 10:34:35 2012 janoschOpticsCharacterizationcamera image

We were confused a bit about how the camera image changes when you move the arm that holds the camera and lens around the mirror. It seems that scattering centers move in ways that cannot be explained by a misaligned rotation axis. So we wanted to make sure that the mirror surface is actually imaged as we intended to. We generated a white grid with 0.7cm spacing and black background on a monitor. The image that we saw is exactly how we expected it to be. So the image mystery has other reasons.

  3   Fri Jul 13 20:53:35 2012 janoschOpticsCharacterizationtwo images

The following two pictures were taken from the same angle with green (left) and red (right) incident laser at an angle of 15deg from the incident beam (reflected to about -5deg). Some scattering centers are collocated. The green laser power is about 5 times as high as the red laser power, but this factor does not seem to calibrate the image well (the green image becomes too dark dividing all pixel values by 5). So there seems to be a significant difference in the divergence of the two lasers. We will have to use a photodiode to get the calibration factor. These images were taken after cleaning the mirror. Before cleaning, there was way too much scattering and the images were mostly saturated.

Green.pngRed.png

  4   Tue Jul 17 18:32:11 2012 janoschOpticsCharacterizationpurple images

We have the new 405nm laser pointer.  The image to the left shows the scattered light from the red laser, the image to the right scattered light from the purple laser. Both images were taken 30deg with respect to the normal of the mirror surface. Also, we got a new gallon of Methanol. After cleaning the mirror multiple times, the scattered light became significantly weaker. So the purple images look very different from red and green. It could be that the lens that we use to image the mirror surface is the problem since it is specified for the wavelength range 1000nm-1550nm. Could it also be the CCD camera? Anyway, to be sure I will order another broadband lens.

Red_30deg.pngPurple_30deg.png

 

  5   Wed Jul 18 18:43:34 2012 janoschOpticsCharacterizationgone with the wind

Here a little purple video. It starts with scattering angle around 15deg and stops at about 80deg.
There are some clear point defects visible especially at small angles.
I will not start to think about some other interesting details of this video before I got the new lens.

Ed: The AVI did not run on Mac. I posted it on youtube. Koji

  6   Fri Jul 20 18:35:42 2012 janoschOpticsCharacterizationpurple improvements and first uncalibrated BSDF curves

Today we improved alignment of the lens-camera arm. We discovered earlier that this alignment affects the amount of "snowfall" on the scattering images. Looking at the latest 405nm video (see attachment), one can still see snowfall, but it is considerably weaker now and the true scatter image is clearly visible. We took a set of scatter images at certain scattering angles and produced BSDF curves. The shape of these curves has partially to do with the snowfall contribution, but one also has to keep in mind that the mirror quality is much worse than what has been used in the Fullerton measurement. We still need to calibrate these curves. The calibration factor is different for the two images so that you cannot even compare them at the moment except for their shape.

Purple_BSDF.pngRed_BSDF.png

Today we also got the new broadband lens for the camera arm. First measurements show that image quality is better. Playing a bit around with distances between object mirror, lens and image plane, we also found that image quality becomes better when the lens and camera get closer to the mirror (which is only an issue for the 405nm measurement since 633nm and 532nm look very good anyway). So we are thinking to change the camera arm setup to make it much shorter.

  7   Tue Jul 24 10:59:59 2012 janoschOpticsCharacterizationsum of purple and red

We played around with Matlab today. The first step was to convert light wavelengths into RGB colors. In this way we can combine images taken at different colors. The picture shows the purple and red images (stored in gray scale) in heat colormap. Then the sum of these two images is calculated in their natural RGB colors.

 

ImageSum.png

  19   Fri May 27 02:09:37 2016 GabrieleMechanicsCharacterizationLowest usable mode of fused silica disks

I did some FEA simulation of fused silica disks, to identify the lowest usable eigenmode. By usable I mean a mode that has zero elastic energy stored in the center. 

Diameter Thickness Frequency
75 mm 1 mm 2500 Hz
100 mm 0.4 mm 564 Hz
200 mm 0.4 mm 141 Hz
75 mm 0.12 mm 293 Hz

In the attached figures, the dfisk deformation is shown exaggerated, and the color map shows the elastic energy density. All results are obtained with COMSOL/MATLAB, the disk are constrained at a point corresponding to the center of the lower surface. No gravity.

  47   Mon Jul 18 13:42:46 2016 GabrieleElectronicsCharacterizationQPD signal convention

The QPD quadrants are wired accoridng to the following convention

  60   Mon Jul 25 15:35:31 2016 GabrieleOpticsCharacterizationCalibration of the QPD in physical units

The equations below are wrong. Please refer to https://nodus.ligo.caltech.edu:8081/CRIME_Lab/116 for the correct results

I measured the properties of the beam on the QPD. The total power is 31 uW. The beam shape is not gaussian, since we are seeing the interference of the reflection from the two surfaces:

The X and Y diameters are 1400 and 1300 microns, so I take the average of the two as an estimate of the beam size: 1300 +- 100 um. I also estimated the lever arm length to be 1.03 +- 0.02 m.

This allows me to esitmate the response of the normalized QPD signal to a tilt of the disk surface:

\frac{s}{P_0}=\frac{4}{\pi w^2} \cdot 2L \cdot \theta_{disk}

Plugging in the numbers gives a gain of (1900 +- 300) /rad for the normalized signals. I implemented those numbers in the filter banks: now X_NORM and Y_NORM have units of radians, and measure the disk surface angular motion. I also calibrated the SUM channel in microwatts, using the nominal responsivity of 0.45 A/W and the transimpedance of 200k (gain 11.1 uW/V)

Here's teh calibrated spectrum: note that the background noise is much larger than the real one because of the signal jumps.

  61   Mon Jul 25 17:44:13 2016 GabrieleElectronicsCharacterizationHigh frequency noise budget

I measured the noise sources limiting the QPD sensitivity. Unfortunately, I had to do some MATLAB tricks to get rid of the glitches: basically I load the data directly from the raw frames (NDS access to data is not working yet) and remove all jumps in the signals that happen in one single sample and are larger than a manually tuned threshold. This is not perfect, but it's enough to give us a rough idea of the spectrum of the QPD signal. The following plot shows the QPD_X signal (in units of disk motion, radians) in a few situations:

  • Blue: normal (laser on, room lights on)
  • Orange: laser on, room lights off (including the vacuum gauge)
  • Yellow: laser and room light off
  • Purple: same as above, but I switched off the PC monitors too
  • Green: QPD electronics off (this is the ADC noise)

The total power on the QPD is 30 uW, which correspond to a shot noise limited sensitivity of 4.3e-12 W/rHz. Considering that the signal is the quadrant asymmetry normalized by the total power, the shot noise limited sensitivity is sqrt(2) * SN / Power which once calibrated corresponds to 1.1e-10 rad/rHz.

The following plot shows that shot noise is the dominant source, followed closely by the electronics dark noise. The total agrees perfectly with the measured background noise above 2 kHz. Below that we have some leakage due to the large turbopump peak: this is due to FFT limitations but mostly to unsuppressed glitches.

From the QPD datasheet (Hamamatsu S5981) I learn that the noise equivalent power should be of the order of 2e-14 W/rHz at the sensitivity peak, so probably a factor of two or so worse at the HeNe frequency. It's still much lower than the measured dark noise. 

This sensitivity is already pretty good, but we can improve it by increasing the power on the diode. Indeed, 30 uW corresponds to about 2.7 V after the transimpedance, so we could increase the power by a factor 4 and win a factor 2 in the shot noise to dark noise ratio. Probably not worth it, since it will give us only a 30% gain in high frequency noise.

  62   Tue Jul 26 11:45:03 2016 GabrieleElectronicsCharacterizationHigh frequency noise budget

Just to confirm that my noise estimates make sense, here's a plot of the not-normalized QPD signal that gives the X motion (sum and difference of all four quadrants):

This is the signal after compensating for the whitening filter. If I remove this compensation, the following plot gives the noises in terms of the voltage directly in input to the ADC (or in output of the analog board):

So the total "dark" electronic noise is about 13 uV/rHz.

I did a roughly estimate of the sources of electronic noise:

  • QPD dark current noise, from datasheet, at the peak sensitivity is equivalent to 2e-14 W/rHz, or 2 nV/rHz at the output of the TI stage
  • First stage: Johnson-Nyquist noise of the TI resistor: 58 nV/rHz
  • First stage: output voltage noise of the LT1124: 3 nV/rHz
  • First stage: input curent noise of the LT1124, converted to the output: 60 nV/rHz

So the total noise at the outoput of the first stage is about 84 nV/rHz. The second stage adds a gain of 30 at high frequency, and negligible noise. So at the output of the whitening we have 2.5 uV/rHz. The DRV135 adds another gain of 2 and a neglegible output noise. 

So the total electronic noise at the output of each quadrant is 5 uV/rHz. Since we are combining four of them, the total expected electronic noise is 10 uV/rHz, which is not too far from the measured value. 

We are basically dominated equally by the Johnson-Nyquist noise of the TI resistor and by the input current noise of the LT1124. No gain to be obtained by changing the whitening.

Quote:

I measured the noise sources limiting the QPD sensitivity. Unfortunately, I had to do some MATLAB tricks to get rid of the glitches: basically I load the data directly from the raw frames (NDS access to data is not working yet) and remove all jumps in the signals that happen in one single sample and are larger than a manually tuned threshold. This is not perfect, but it's enough to give us a rough idea of the spectrum of the QPD signal. The following plot shows the QPD_X signal (in units of disk motion, radians) in a few situations:

  • Blue: normal (laser on, room lights on)
  • Orange: laser on, room lights off (including the vacuum gauge)
  • Yellow: laser and room light off
  • Purple: same as above, but I switched off the PC monitors too
  • Green: QPD electronics off (this is the ADC noise)

The total power on the QPD is 30 uW, which correspond to a shot noise limited sensitivity of 4.3e-12 W/rHz. Considering that the signal is the quadrant asymmetry normalized by the total power, the shot noise limited sensitivity is sqrt(2) * SN / Power which once calibrated corresponds to 1.1e-10 rad/rHz.

The following plot shows that shot noise is the dominant source, followed closely by the electronics dark noise. The total agrees perfectly with the measured background noise above 2 kHz. Below that we have some leakage due to the large turbopump peak: this is due to FFT limitations but mostly to unsuppressed glitches.

From the QPD datasheet (Hamamatsu S5981) I learn that the noise equivalent power should be of the order of 2e-14 W/rHz at the sensitivity peak, so probably a factor of two or so worse at the HeNe frequency. It's still much lower than the measured dark noise. 

This sensitivity is already pretty good, but we can improve it by increasing the power on the diode. Indeed, 30 uW corresponds to about 2.7 V after the transimpedance, so we could increase the power by a factor 4 and win a factor 2 in the shot noise to dark noise ratio. Probably not worth it, since it will give us only a 30% gain in high frequency noise.

 

  73   Tue Aug 2 16:00:32 2016 GabrieleElectronicsCharacterizationMore on the signal jumps

So I’m sending a 1.123 Hz sinusoid into the ADC, and generating 3.123 Hz sines and cosines in the model. Frequencies are reasonably incommensurable with one second.

The plots below shows all three signals. In the top panels, I just separate the two segments in each second: the “normal” segment in blue, and the “jumped” segment in orange.
In the bottom panels, I took the jumped segments (orange) and shifted them “in the future” by exactly one second. The signals are perfect!
 
I think we could explain this if the order of the samples in each second is scrambled, like we have a circular buffer but we point to the wrong starting point…
 
 
  105   Thu Sep 1 02:13:33 2016 GabrieleOpticsCharacterizationExpected frequencies for the 75 mm disks with flats

Here are the nominal parameters of the disk with flats

Parameter Value
Diameter (nominal) 75.0 mm
Thickness (nominal) 1.00 mm
Distance of flats from center of disk
(as measured by MO)
36.05 mm
Young's modulus (from G1601850) 72.3 GPa
Poisson's ratio (from G1601850) 0.164
Density 2202 kg/m^3

A COMSOL simulation gives the frequencies and mode shapes shown in the attached PDF file. Following the list of frequencies and a classification of the mode family (numer of radial nodes, number of azimuthal nodes in a half turn):

Frequency [Hz] Radial Azimuthal
1089.7 0 2
1109.1 0 2
1661.1 1 0
2501.3 0 3
2542.3 0 3
3837.7 1 1
3909.8 1 1
4359.9 0 4
4421.2 0 4
6656 0 5
6665.3 1 2
6732.7 0 5
6780 1 2
7283.9 2 0
9381.5 0 6
9470.6 0 6
10054.1 1 3
10210.2 1 3
11244.2 2 1
11414.2 2 1
12528.4 0 7
12655.4 0 7
13970.1 1 4
14148.9 1 4
15854.8 2 2
15856.8 2 2
16101.1 0 8
16227.8 3 0
16853.9 3 0
18387.2 1 5
18562.6 1 5
19984.9 0 9
20045.8 0 9
21067.2 2 3
21358.1 2 3
22300.9 3 1
22848.8 3 1
23270.5 1 6
23419.4 1 6
24374.1 0 10
24425.2 0 10
26793.8 2 4
27083.9 2 4
28533.5 1 7
28637.8 1 7
28692 3 2
28998.5 4 0
29228.3 0 11
29271.9 0 11
29870.1 4 0
33040 2 5
33301.4 2 5
33949.1 0 12
33986.5 0 12
  207   Tue Nov 22 08:21:35 2016 GabrieleElectronicsCharacterizationADC saturation

Last night measurements didn't work well: even without exciting the modes, the ADC was saturating because of the low frequency signal, particularly a 58 Hz peak:

When the modes were rang up, thing got clearly even worse:

Modification of whitening filter

So I modified the whitening filter, changing C6 from 2.2u to 220nF. The old and new whitening filters are shown below. We have the same amount of whitening at high frequency, but less amplification of the junk at ~50-100 Hz

With this modification, there's no more saturation, even when the modes are excited.

  289   Wed Feb 1 16:58:10 2017 GabrieleGeneralCharacterizationExcitation tests

The excitation is working fine. However, there is a large cross coupling in the excitation between channels: so if I switch on only one of the ESD paths, I actually excite all other disks too.  It might be due to the common ground or to the fact that the cables run close to each other. This needs some investigation, but it's not a big issue for the moment being.

On the other hand, the optical levers are very well decoupled: each one sees a different set of modes. So there is no measurable cross coupling between the disks or the readout.

There seems to be something fishy with the Y picomotor of QPD3: it doesn't always move in the same direction for the same set of steps. Some investigations needed here too. Autocentering might fail, but it's still possible to center it manually.

Excitation at 4:56pm (quiet time before excitation 1170032165, quiet time after excitation 1170032234).

Another excitation at 8:30am (2017-02-02) (quiet time before excitation 1170088185, quiet time after excitation 1170088373)

  413   Wed Aug 16 14:35:05 2017 GabrieleGeneralComputersWorkstation is down

While I was working, the network connection went down. I tried to reboot the workstation, but I won't boot anymore.

  • First issue: firmware of network card disappeared. I managed to download it on a USB stick and install it back
  • Second issue: mismatch of NVIDIA graphic card drivers and kernel. Can't start X

Working on it...

  418   Fri Aug 18 14:05:36 2017 GabrieleGeneralComputersWorkstation is now up

Reinstalled Debian 8, all packages and CDS software.

Everything seems to be working fine now.

Quote:

While I was working, the network connection went down. I tried to reboot the workstation, but I won't boot anymore.

  • First issue: firmware of network card disappeared. I managed to download it on a USB stick and install it back
  • Second issue: mismatch of NVIDIA graphic card drivers and kernel. Can't start X

Working on it...

 

  22   Fri Jun 10 13:44:06 2016 GabrieleElectronicsConfigurationHow to setup a workstation

Instructions on how to setup a workstation are available here:

https://nodus.ligo.caltech.edu:8081/Cryo_Lab/1135

I'll copy them here and integrate once I got the C.Ri.Me. workstation up and running

 

** libmotif4 >> libxm4 : sudo apt-get install libxm4

** all .sh files in etc must be modified to point to the correct version of the downloaded software

** add the following line to the end of the ligoapps-userv-end.sh file to get medm and striptool working

PATH="/ligo/apps/ubuntu12/epics-3.14.12.3_long/extensions/bin/linux-x86_64:$PATH"

** to fix diaggui problem, create a symbolic link in /usr/lib/x86_64-linux-gnu/

sudo ln -s libtiff.so.5 libtiff.so.4

  26   Wed Jun 29 16:44:17 2016 GabrieleGeneralConfigurationFirst disk eigenfrequency

The following table shows the lowest eigenfrequency (Hz) for different sizes of disks

Diameter \ Thickness [mm] 0.125 0.250 0.500 1.000
75 137 273 545 1090
100 77 154 307 613
150 34 68 136 272
200 19 38 77 153

  34   Fri Jul 8 16:49:11 2016 GabrieleElectronicsConfigurationCyMAC

In the last days Jamie installed the patched kernel to run the real time system (RTS) on the new CyMAC. Today (with Jamie's remote advices) I managed to get a IOP (input output process) model compiled and running. There is still no timing input (to be fixed at the beginning of the netx week, I'm presently missing a connector which is on order).

Running the x1iop model gives:

controls@cymac3:/opt/rtcds/tst/x1/scripts$ ./startx1iop 

x1iopepics: no process found

Number of ADC cards on bus = 1

Number of DAC16 cards on bus = 1

Number of DAC18 cards on bus = 0

Specified filename iocX1.log does not exist.

x1iopepics X1 IOC Server started

 

controls@cymac3:/opt/rtcds/tst/x1/scripts$ awg_server Version $Id: awg_server.c 2917 2012-05-22 22:33:39Z alexander.ivanov@LIGO.ORG $

channel_client Version $Id: gdschannel.c 4170 2016-04-05 21:24:46Z jonathan.hanks@LIGO.ORG $

testpoint_server Version $Id: testpoint_server.c 3303 2013-03-05 23:33:45Z alexander.ivanov@LIGO.ORG $

/opt/rtcds/tst/x1/target/gds/bin/awgtpman -s x1iop -4 -l /opt/rtcds/tst/x1/target/gds/awgtpman_logs/x1iop.log started on host cymac3 hostid ffffffffd783d97b 

awgtpman Version $Id: awgtpman.c 4170 2016-04-05 21:24:46Z jonathan.hanks@LIGO.ORG $

 
which seems reasonable. Also, the GDT TP medm screen shows something running:
 
 
Here's what I had to do to get the models to compile and run:
 

1) install MATLAB and add to startup.m the following line

addpath(genpath('/opt/rtcds/rtscore/release/src/epics/simLink'))

 

2) copied from cymac2 the file /opt/rtcds/rtcds-user-env.sh and changed the content to match the right folders

 

3) installed readline library which was missing: apt-get install 

sudo apt-get install libreadline-dev

 

4) installed linux headers sudo apt-get install linux-headers-3.2.0-rts-amd64

 

5) created symbolic link to linux headers:

sudo ln -s /usr/src/linux-headers-3.2.0-rts-common /usr/src/linux

 

6) changed host name to cymac3

sudo vi hostname

 

7) created symbolic link to lspci 

sudo ln -s /usr/bin/lspci /usr/sbin/lspci

 

8) created a symbolic link to awgtpman

ln -s /usr/bin/awgtpman /opt/rtcds/tst/x1/target/gds/bin/awgtpman

  35   Mon Jul 11 08:49:25 2016 GabrieleElectronicsConfigurationCymac RTS configuration

I copy here parts of an email from Jamie with instructions on how to run the RTS on the cymac:

I had to change the site/ifo to be "caltech/x3" to avoid EPICS
collisions with other cymacs.  You'll need to update your models to
reflect this change (change names, site/ifo parameters in the model,
etc.).  So for instance, change x1iop -> x3iop, and update the params
block inside.

daqd is installed and running, although I haven't really stress tested
it yet (no models/channels/etc).  It's running under systemd, which is
the Debian service management system.  You can control daqd with the
following commands:

# systemctl restart daqd
# systemctl stop daqd
# systemctl start daqd
# systemctl status daqd
# journalctl --unit=daqd

controls@cymac3:~ 0$ systemctl status daqd
● daqd.service - Advanced LIGO RTS daqd service
  Loaded: loaded (/etc/systemd/system/daqd.service; enabled)
  Active: active (running) since Sat 2016-07-09 11:22:38 PDT; 23h ago
Main PID: 20827 (daqd-standiop)
  CGroup: /system.slice/daqd.service
          └─20827 /usr/bin/daqd-standiop -c /etc/advligorts/daqdrc
controls@cymac3:~ 0$ sudo journalctl --unit=daqd
...

Remember to restart daqd ("systemctl restart daqd") after you add/change
models.

I've gotten all the RCG components working, but not without some small
kinks.  The RCG currently expects a specific EPICS install, different
than the system install we're using right now.  I've hacked a way to
make this work seemlessly for model builds, but it requires sourcing the
following file before *starting* models:

/opt/rtapps/epics/etc/epics-user-env.sh

So in the mean time, you can start/stop models via the following:

$ . /opt/rtapps/epics/etc/epics-user-env.sh
$ /opt/rtcds/caltech/x3/scripts/startx1iop

 

  40   Thu Jul 14 15:30:48 2016 ericqElectronicsConfigurationCymac RTS configuration

We played around a bit with the cymac, in efforts to make things better.

  • We disabled some more fancy-sounding options in the machine's BIOS
  • I created safe.snap files for the x3iop and x3tst models 
    • x3iop's was created by booting the model while mashing the EPICS command to set the burt restore bit, and then saving the EPICS database to file via the SDF screen
    • x3tst's was created by copying an existing .snap file 
  • I gave the controls user ownership of /frames via sudo chown controls:controls /frames
  • I then created the following folders (which the daqd log was complaining about not finding_
    • /frames/full
    • /frames/trend/minute
    • /frames/trend/minute_raw
    • /frames/trend/second
  • I also created the folder /opt/rtcds/tst/x3/target/fb, since that is listed in the daqd config as the nds job dir. (However nds does not seem to be running. Is it needed? I couldn't compile it in the rtbuild directory)

As I see it, the main problems that persist are:

  • daqd crashes over and over again every few seconds
    • The logs seem to be complaining about EPICS server problems. Is the related to whatever situation made the epics-env script neccessary?
  • The IOP seems to be taking too much time: 8-9 usec
    • This is especially problematic as Gabriele actually wants to run the IOP at an even faster rate than the current 64k, which isn't possible with the current timing
  42   Thu Jul 14 17:06:47 2016 GabrieleElectronicsConfigurationNetworking

The laboratory workstation is coatings.ligo.caltech.edu

The RTS is cymac3.ligo.caltech.edu

I set up a ssh-mount of the /opt/rtcds/userapps folder in the workstation. I also created shared ssh keys for the controls user, so we can ssh into the cymac3 without password

  50   Mon Jul 18 17:48:58 2016 GabrieleElectronicsConfigurationStatus of real time system and workstation

[EricQ, Gabriele]

The real time system seems to be working properly, except for the excitations: we can't activate any excitation using awggui or diaggui

Eric rebuilt the workstation from scratch installing Debian 8.5. All CDS software seem to be working. We setup a ssh-key for ssh'ing into cymac3 and configured the automatic mount of the remote /opt/rtcds.

  54   Tue Jul 19 20:19:38 2016 GabrieleElectronicsConfigurationGlitches are a digital artifact

The glitches I saw in the data happens roughly every second, even though not exactly on the second. They are suddend jumps on the signal values over one sample, so of clear digital origin

 

  55   Wed Jul 20 10:26:40 2016 GabrieleElectronicsConfigurationAre glitches a digital artifact?

Not so sure anymore...

  • those glitches do not happen at regular times
  • I tried to send a sinusoid into another ADC channel, and I couldn't see any jump
  • using DTT and zooming into the jumps, they don't seem a clean one-sample jump anymore... There might be a bit of ringing before and/or after the jump
  • The jumps have different sizes and directions, and they seems to happen at the same time in all four quadrants, but not in the same direction or with the same amplitude

I was suspecting dust crossing the beam, so I build a very rough enclosure, that should help with dust. I don't think I saw any change in the glitches. 

Also:

  • glitches are there even with the HeNe off, with ambient light only. So it's not the laser.
  • I tried sending a sinusoid into one of the same ADC channels used to acquire the QPD signals. I couldn't see any glitch

So one might conclude that the glictches are produced by the analog QPD electronics. However, I plugged in a scope and I couldn't see any in the analog signal. But I checked only before the DRV135 stages. I'll need some sort of breakout board to test the output of the DRV135.

Quote:

The glitches I saw in the data happens roughly every second, even though not exactly on the second. They are suddend jumps on the signal values over one sample, so of clear digital origin

 

 

  58   Fri Jul 22 14:22:10 2016 GabrieleElectronicsConfigurationInvestigations on the signal jumps

[Rolf, Ben, Rich, Gabriele]

Rolf couldn't find any good explanation on the software side for the signals jumps. He investigated a bit the reason why IOP takes a long execution time, without success. It's still mysterious why it ran with low time for a while.

One effect of Rolf activity is that now the signal jumps happen at ~0.8 seconds (after the start of each second) instead that ~0.45. This is suspiciously pointing to a software issue...

Ben and I spent a few hours trying to better understand the origin of the glitches. Finally, we plugged in a function generator to the four ADC channels, and we could find the glitches again, at the expected time. So we could rule out completely that it's a problem of the QPD analog electronics.

Some more ivnestigations:

  • swapped the SR DS345 with an Agilent 33210A for the timing signal. No change: jumps are still there
  • rebooted and powered off the cymac many time, this never changed the glitches or the position in time
  • swapped the ADC interface board (D1600196) with a new one similar to that of the crackle lab (D1500402): no change, jumps are still there
  • switched off the roughin pump to reduce ambient acoustic noise. Not surprisingly, no change, still jumps
  • according to the motherboad manual, PCIe slots 4 and 6 are PCI-EX16, while the other are PCI-EX8. I moved the ADC and DAC to those those slots. Guess what? No change, still jumps

On a bright side, Rolf recompiled the awgman software, and now excitation channels are working.

  59   Mon Jul 25 12:24:06 2016 GabrieleElectronicsConfigurationMore on the signal jumps

Here are two more tests I did this morning

  • removed the DAC card from the cymac and the models, and restarted everything: signal jumps are still there
  • move the cymac2 from the crackling noise lab to the CRIME lab, ans set it up with all the same hardware I was using with the cymac3: there are no jumps, signals look perfect (see plots at the end)

So in conclusion: the problem is in the cymac3 computer, either software or hardware. I tend to excluse an I/O hardware problem, since I used two different ADCs and removed the DAC, without improving the situation.

  64   Wed Jul 27 10:19:36 2016 GabrieleElectronicsConfigurationLast finding in the signal jump saga

This plot shows a signal which is generated purely digitally inside a code that I was testing.

Jumps are present even in this case.

Another addition: I was testing some simple code I was writing. Forget about OUT1 and OUT2, but OUT3 and OUT4 should be simple counters. Here's what I get by running the code on cymac3:

Since it didn't make any sense, I ran the same code on cymac2. Here's the (correct) result:

So there's something wrong even when all-digital signals are generated.

  78   Thu Aug 11 09:10:01 2016 GabrieleElectronicsConfigurationReal time model

Compiled and installed an updated real time model. It acquires the four QPD segments, compute sum and differences, and normalize. I also added three experimental peak tracking components, that will be used to track in real time the amplitude and frequency of the disk modes.

I also created a summary medm screen that can be used to control all the QPD readout. It can be opened from any terminal with the command 'cr1'. I haven't added the peak tracking parts yet.

The X_NORM_OUT and Y_NORM_OUT signals are high passed at 500 Hz, to get rid of low frequency stuff that can affect the peak tracking.

 

  79   Thu Aug 11 10:59:39 2016 GabrieleElectronicsConfigurationQuadrant calibration

I cross checked the calibration of the sum channel with a  power meter. Now all quadnant signals X3:Q?_OUT and the sum signal X3:CR1-SUM_OUT are correctly calibrated in microwatts.

  80   Fri Aug 12 10:33:14 2016 GabrieleElectronicsConfigurationStorage added to cymac3

Installed two new 2TB disks into the cymac3. Also, the main disk has a 1TB partition with the operating system, so I created a new 1TB partition. I created a logic volume that spans the three partitions, for a total of about 5TB. This partition is mounted in /mnt/data and linked to the /frames folder. Frames are written to this new logic volume.

  87   Tue Aug 16 11:57:03 2016 GabrieleElectronicsConfigurationFixed cymac3 network and time issue

The cymac3 internal clock was off by about 10 seconds. When I tried to start the NTP service, I found out that the cymac3 couldn't reach any external server. It turned out that the gateway in /etc/network/interfaces was set to the wrong address. I fixed it and rebooted. Now NTP is working and the time is correct.

This fixed a small issue with diaggui, which always complained about a data receiving error when starting a measurement (although after the complian the measurement could continue)

  122   Thu Sep 22 13:39:40 2016 GabrieleOpticsConfigurationUpdated design for the new C.Ri.Me. setup

Today I measured the amount of space available on the table for the new (4-fold) C.Ri.Me. setup. It's 1050 x 1220 mm, with the table hole in it. 

So I updated the optical layout to fit into this space, and optimized the telescope to have a beam spot on the QPD of the order of 350 um. The average lever arm length is 1.5 m, so the optical gain will be about 7000 /rad.

 

  123   Thu Sep 22 15:00:49 2016 GabrieleElectronicsConfigurationEpics values now saved to frames

I was looking at some past trend data and discovered that EPICS values were not written to the frames. I added the following two lines to /opt/rtcds/tst/x3/target/fb/master to fix this:

/opt/rtcds/tst/x3/chans/daq/X3EDCU_CR1.ini
/opt/rtcds/tst/x3/chans/daq/X3EDCU_TST.ini
  125   Fri Sep 23 08:33:39 2016 GabrieleElectronicsConfigurationEpics values now saved to frames

Now EPICS values are saved to frames, but they are all zero! I noticed that we always had the same problems with the cymac2 too.

So for the moment being I set up daqd to save X_NORM_IN1 and Y_NORM_IN1 at 32 Hz. In this way I can monitor the QPD centering.

Quote:

I was looking at some past trend data and discovered that EPICS values were not written to the frames. I added the following two lines to /opt/rtcds/tst/x3/target/fb/master to fix this:

/opt/rtcds/tst/x3/chans/daq/X3EDCU_CR1.ini
/opt/rtcds/tst/x3/chans/daq/X3EDCU_TST.ini

 

  126   Mon Sep 26 15:54:01 2016 GabrieleFacilityConfigurationMoved vacuum controllers

I moved the turbo pump controller out of the clean room. Also, I installed the gauge controller on the Cymac rack.

  129   Tue Sep 27 14:54:53 2016 GabrieleElectronicsConfigurationEpics values now saved to frames

Apparently, there was a mismatch in the configuration, and DAQD was adding a wonderful 16 Hz comb all over the spectrum.

I stopped the processes, but couldn't restart x3cr1. It turned out that I can't save a channel to frames with a sampling frequency lower than 256 Hz. I changed the model, recompiled and restarted. Now the 16 Hz is gone.

Quote:

Now EPICS values are saved to frames, but they are all zero! I noticed that we always had the same problems with the cymac2 too.

So for the moment being I set up daqd to save X_NORM_IN1 and Y_NORM_IN1 at 32 Hz. In this way I can monitor the QPD centering.

Quote:

I was looking at some past trend data and discovered that EPICS values were not written to the frames. I added the following two lines to /opt/rtcds/tst/x3/target/fb/master to fix this:

/opt/rtcds/tst/x3/chans/daq/X3EDCU_CR1.ini
/opt/rtcds/tst/x3/chans/daq/X3EDCU_TST.ini

 

 

  143   Fri Oct 21 15:27:15 2016 GabrieleElectronicsConfigurationRemoved low pass filter in SUM

I removed the low pass filter in the QPD SUM signal, used for normalization. This reduced a lot the bump at ~20kHz due to laser intensity noise.

I also switched off the 500 Hz high pass filters in the X_NORM and Y_NORM signals.

  158   Fri Nov 4 11:31:11 2016 GabrieleElectronicsConfigurationAutocenter control and model modifications

Removed the peak meter lock from the model, since it's not used

Added and EPICS binary bit to control the autocenter, added corresponding buttons to the MEDM screen.

Now the GUI stops the autocentering when acquiring the reference spectrum.

The auto_excite.py also stops the autocentering 35 seconds before the excitation and until 35 second after the excitation, to provide for two reference quiet periods.

  173   Thu Nov 10 14:13:34 2016 gabrieleElectronicsConfigurationMATLAB code to control Thorlabs stages

To be used to automate the laser polishing.

  217   Tue Nov 29 17:06:13 2016 GabrieleElectronicsConfigurationChanged whitening filters of four more boards

I modified four more QPD boards to implement the new whitening filters detailed in elog 207.