Entry  Thu Aug 17 14:19:04 2017, Zach, Electronics, Modeling, Two ESD Optimization 17x
2017-08-17


I ran a sweep of the position of the middle ESD to determine the optimal arrangement. From the original geometry I offset
the central ESD between -2 mm and 11 mm. From the plots below I conclude that the optimal geometry is the one that is shifted 2 mm to the right of the
original design. 
The first plot is the sweep data as a ratio to the data of the current geometry for all modes. The second plot is the
Entry  Wed Feb 8 17:01:01 2017, Gabriele, Optics, Daily Progress, Two laser installed, setup aligned photo_setup_new.png
Today I swapped out the 8mW laser and installed two 2.5 mW lasers. I rebuilt the input part of the optical levers and re-aligned everything. See
below for a picture of the new setup: red beams are input, yellow beams are output. I also installed a protective screen all around the table, to abvoid
any suprios beam to get out.
    Reply  Thu Feb 9 09:30:52 2017, Gabriele, Optics, Daily Progress, Two laser installed, setup aligned Screenshot.png
The lasers are behaving well, there is no high noise or wandering lines. The spectrum below is taken in air: that explains the excess of noise in the
few kHz region.

Entry  Tue Aug 15 16:43:58 2017, Zach, Electronics, Modeling, Unchanged Mode Insight Double.pdfThin.pdfOriginal.pdf
2017-08-15


It appears to me that the major factor limiting the improvement of the modes that either remain equal or diminish is that
the original design was already quite good at exciting those modes. As can be seen in the attached plots, the original design is about as well centered
over the 5 modes as a rectangle on the x axis can be. As a result, maintaing a constant potential on the ESD it would be difficult to improve the coupled
Entry  Tue Dec 12 15:35:27 2017, Gabriele, General, Measurements, University Wafers substrates (76.2mm/0.5mm) annelaed 
2017-12-12

Four substrates from University Wafers (76.2mm / 0.5mm) in chamber


3:32pm in chamber (CR1 - CR4)
3:35pm roughing pump on
3:45pm turbo pump on
Excitations:

Quiet
time before excitation: 1197168131
Entry  Thu Sep 22 13:39:40 2016, Gabriele, Optics, Configuration, Updated design for the new C.Ri.Me. setup crime_v2.pdf
Today I measured the amount of space available on the table for the new (4-fold) C.Ri.Me. setup. It's 1050 x 1220 mm, with the table hole in it. 

So I updated the optical layout to fit into this space, and optimized the telescope to have a beam spot on the QPD of the order of 350 um. The
average lever arm length is 1.5 m, so the optical gain will be about 7000 /rad.
Entry  Fri Mar 10 16:44:13 2017, Gabriele, Optics, Daily Progress, Updated in vacuum periscope of CR0 
This afternoon I removed the old periscope from CR0 and installed a new one with finely adjustable mount, like those in the new chamber. I realigned
the optical lever to the horizontal refererence.
Entry  Wed Jul 27 15:43:02 2016, Gabriele, Facility, Daily Progress, Vacuum chamber dismantled and ready for cleaning 2016-07-27_15.34.10.jpg
[Alena, Gabriele]

As decided at out Red Door meeting, we're going to clean the vacuum chamber and move it to the large table, which will be enclosed in a clean
room.
Entry  Thu Jul 7 17:44:11 2016, Gabriele, Facility, Daily Progress, Vacuum chamber tests 2016-07-07_14.33.34.jpg2016-07-07_14.35.21.jpg2016-07-07_15.55.19.jpg2016-07-07_14.35.26.jpg2016-07-07_15.01.22.jpg
[Alena, Gabriele]

This afternoon we opened the tall belljar vacuum chamber, and took everything out of it. All the stuff that was inside the chamber is "temporarily"
stored on the floor beside the optical table.
Entry  Fri Jul 8 15:26:37 2016, Alena, Facility, Daily Progress, Vacuum chamber tests WP_20160708_12_25_35_Pro.jpgWP_20160708_12_25_41_Pro.jpg
Fixed the 307 gauge controller (a missing contact on the rair panel). The low pressure gauge was connected to 1G port and has measured 1.7E-6 torr. We
are not sure since how long the turbo was operating (no vacuum logger yet).

 
Entry  Mon Jul 11 14:56:45 2016, Alena, Facility, Daily Progress, Vacuum chamber tests 20160711.png
Installed a gate valve between the roughing and tubbo pump. See below a pump down curve. The convection gauge is not calibrated. the turbo started at
14th min (at about 3 torr)
    Reply  Mon Jul 11 17:04:06 2016, Alena, Facility, Daily Progress, Vacuum chamber tests 
At 5pm the pressure was 6.5e-6 torr.

Checked again at:


9am, pressure was 2e-6 torr
11:30am, pressure was 1.5e-6 torr
5pm, pressure was 1.4e-6 torr


Entry  Tue Jul 19 17:15:37 2016, Gabriele, Facility, Daily Progress, Vacuum pressure acquired 
[Alena, Gabriele]

We connected the analog output of the vacuum gauge controller to one of the ADC channels. The signal is calibrated so that the pressure is 10^(X3:CR1-PRESSURE_LOGTORR_OUT).
Unfortunately the RTG does not know how to compute 10^x...
Entry  Mon Nov 14 11:28:33 2016, Gabriele, General, Vacuum, Viton pads 2016-11-14_10.41.47.jpg2016-11-14_10.41.57.jpgviton.png
I added three 1"x1" viton pads below the base plate, and realigned the entire optical system to the horizontal reference

Entry  Wed Feb 1 15:23:42 2017, Gabriele, Optics, Noise hunting, Wandering line is due to the laser laser_noise_rin.pngUntitled.avi
The wandering line I mentioned in my previous elog, which is spoiling most of the sensitivity, turns out to be power noise of the laser. 

I used a Thorlabs PDA100 and a SR785 to measure the power noise out of the laser directly, and saw a huge forest of peaks above 20kHz. Among
them, a couple of peaks are moving up and down in frequency very fast. The plot below compares two different times of the Thorlabs HNL210L laser (the new
Entry  Sun Aug 21 13:45:56 2016, Gabriele, Optics, Daily Progress, Wierd behavior of ring downs and Improved setup second_ring_downs.pngthird_ring_downs.png2016-08-21_08.46.11.jpg2016-08-21_13.29.24.jpg2016-08-21_13.29.32.jpg
The last two ring downs I measured today showed a weird behavior of the lowest modes:

Entry  Wed Aug 16 14:35:05 2017, Gabriele, General, Computers, Workstation is down 
While I was working, the network connection went down. I tried to reboot the workstation, but I won't boot anymore.


First issue: firmware of network card disappeared. I managed to download it on a USB stick and install it back
Second issue:
mismatch of NVIDIA graphic card drivers and kernel. Can't start X


Working on it...
    Reply  Fri Aug 18 14:05:36 2017, Gabriele, General, Computers, Workstation is now up 
Reinstalled Debian 8, all packages and CDS software.

Everything seems to be working fine now.




Entry  Fri Mar 30 19:12:15 2018, Gabriele, General, Measurements, Zirconia S1600519 S1600522 S1600565 
2018-03-30


7:10pm in chamber

S1800634 (Zirconia) in CR1
S1600519 in CR2
S1600522 in CR3
S1600565
in CR4


7:12pm roughing pump on
7:20pm turbo pump on
Entry  Fri Jul 13 10:34:35 2012, janosch, Optics, Characterization, camera image 
We were confused a bit about how the camera image changes when you move the arm that holds the camera and lens around the mirror. It seems that
scattering centers move in ways that cannot be explained by a misaligned rotation axis. So we wanted to make sure that the mirror surface is actually imaged
as we intended to. We generated a white grid with 0.7cm spacing and black background on a monitor. The image that we saw is exactly how
    Reply  Wed Feb 1 15:35:30 2017, Gabriele, General, Daily Progress, excitation not working - FIXED 
My bad, a cable was disconnected.




Quote:



 
Entry  Wed Jul 18 18:43:34 2012, janosch, Optics, Characterization, gone with the wind Purple.avi
Here a little purple video. It starts with scattering angle around 15deg and stops at about 80deg. 
There are some clear point defects visible especially at small angles. 
I will not start to think about some other interesting details of this video before I got the new lens.
Entry  Tue Jul 17 18:32:11 2012, janosch, Optics, Characterization, purple images Red_30deg.pngPurple_30deg.png
We have the new 405nm laser pointer.  The image to the left shows the scattered light from the red laser, the image to the right scattered
light from the purple laser. Both images were taken 30deg with respect to the normal of the mirror surface. Also, we got a new gallon of Methanol. After
cleaning the mirror multiple times, the scattered light became significantly weaker. So the purple images look very different from red and green.
Entry  Fri Jul 20 18:35:42 2012, janosch, Optics, Characterization, purple improvements and first uncalibrated BSDF curves Purple.mp4Red.mp4Purple_BSDF.pngRed_BSDF.png
Today we improved alignment of the lens-camera arm. We discovered earlier that this alignment affects the amount of "snowfall" on the scattering
images. Looking at the latest 405nm video (see attachment), one can still see snowfall, but it is considerably weaker now and the true scatter image is
clearly visible. We took a set of scatter images at certain scattering angles and produced BSDF curves. The shape of these curves has partially to do with
Entry  Fri Oct 12 16:23:20 2012, janosch, Optics, Daily Progress, reassembled setup 
Nothing has happened since Steve, the visiting highschool teacher, has left. Meanwhile, some parts of the multi-color BRDF setup were delivered.
I assembled everything today and realigned the lasers. Everything is ready now for a three-color BRDF measurement (the previous Richter record was 2 colors).
I will claim back my video capture device as soon as possible from my neighbors and then take new images.
Entry  Wed Sep 28 10:26:58 2016, rana, General, General, references on ideal glasses 
Some easy to read reviews on thin films and ideal glass for people getting started in this Q measuring game.



M.
D. Ediger, in PNAS  (2014), pp. 11232–11233.


A. J. Leggett and D. C. Vural, arXiv cond-mat.dis-nn, arXiv:1310.3387 (2013).
Entry  Wed Jul 11 23:01:01 2012, janosch, Optics, Characterization, starting the multi-color scatter experiment DSCF3148.JPGDSCF3151.JPGDSCF3150.JPG
Steve Maloney, a visiting highschool teacher, and I have started to set up a new scattering experiment in the Richter lab. The idea is to take images
of large-angle scattered light using different lasers. We have one 633nm laser, and 532nm and 405nm laser pointers. The goal is to uniformly illuminate
the same disk of about 1cm diameter on a silver-coated mirror with all three colors. We use a silver-coated mirror to make sure that the light is reflected
Entry  Tue Jul 24 10:59:59 2012, janosch, Optics, Characterization, sum of purple and red ImageSum.png
We played around with Matlab today. The first step was to convert light wavelengths into RGB colors. In this way we can combine images taken at different
colors. The picture shows the purple and red images (stored in gray scale) in heat colormap. Then the sum of these two images is calculated in their natural
RGB colors.
Entry  Thu Jul 14 16:56:00 2016, Alena, Facility, Daily Progress, test vacuum system 
Please see prosidures for pumping down and venting with air for the test vacuum chamber here https://dcc.ligo.org/T1600304
Entry  Fri Jul 13 20:53:35 2012, janosch, Optics, Characterization, two images Green.pngRed.png
The following two pictures were taken from the same angle with green (left) and red (right) incident laser at an angle of 15deg from the incident beam
(reflected to about -5deg). Some scattering centers are collocated. The green laser power is about 5 times as high as the red laser power, but this
factor does not seem to calibrate the image well (the green image becomes too dark dividing all pixel values by 5). So there seems to be a significant