ID Date Author Type Category Subjectup Text Attachments
  415   Thu Aug 17 14:19:04 2017 ZachElectronicsModelingTwo ESD Optimization2017-08-17


I ran a
sweep of the position of the middle ESD to
determine the optimal arrangement. From the
 17x 
  296   Wed Feb 8 17:01:01 2017 GabrieleOpticsDaily ProgressTwo laser installed, setup alignedToday I swapped out the 8mW laser
and installed two 2.5 mW lasers. I rebuilt
the input part of the optical levers and
 photo_setup_new.png 
  300   Thu Feb 9 09:30:52 2017 GabrieleOpticsDaily ProgressTwo laser installed, setup alignedThe lasers are behaving well, there is
no high noise or wandering lines. The spectrum
below is taken in air: that explains the
 Screenshot.png 
  409   Tue Aug 15 16:43:58 2017 ZachElectronicsModelingUnchanged Mode Insight2017-08-15


It appears
to me that the major factor limiting the
improvement of the modes that either remain
 Double.pdfThin.pdfOriginal.pdf 
  447   Tue Dec 12 15:35:27 2017 GabrieleGeneralMeasurementsUniversity Wafers substrates (76.2mm/0.5mm) annelaed2017-12-12

Four substrates
from University Wafers (76.2mm / 0.5mm) in
chamber
  
  122   Thu Sep 22 13:39:40 2016 GabrieleOpticsConfigurationUpdated design for the new C.Ri.Me. setupToday I measured the amount of space available
on the table for the new (4-fold) C.Ri.Me.
setup. It's 1050 x 1220 mm, with the
 crime_v2.pdf 
  331   Fri Mar 10 16:44:13 2017 GabrieleOpticsDaily ProgressUpdated in vacuum periscope of CR0This afternoon I removed the old periscope
from CR0 and installed a new one with finely
adjustable mount, like those in the new chamber.
  
  66   Wed Jul 27 15:43:02 2016 GabrieleFacilityDaily ProgressVacuum chamber dismantled and ready for cleaning[Alena, Gabriele]

As decided at out Red Door meeting,
we're going to clean the vacuum chamber
 2016-07-27_15.34.10.jpg 
  31   Thu Jul 7 17:44:11 2016 GabrieleFacilityDaily ProgressVacuum chamber tests[Alena, Gabriele]

This afternoon we opened the tall
belljar vacuum chamber, and took everything
 2016-07-07_14.33.34.jpg2016-07-07_14.35.21.jpg2016-07-07_15.55.19.jpg2016-07-07_14.35.26.jpg2016-07-07_15.01.22.jpg 
  33   Fri Jul 8 15:26:37 2016 AlenaFacilityDaily ProgressVacuum chamber testsFixed the 307 gauge controller (a missing
contact on the rair panel). The low pressure
gauge was connected to 1G port and has measured
 WP_20160708_12_25_35_Pro.jpgWP_20160708_12_25_41_Pro.jpg 
  36   Mon Jul 11 14:56:45 2016 AlenaFacilityDaily ProgressVacuum chamber testsInstalled a gate valve between the roughing
and tubbo pump. See below a pump down curve.
The convection gauge is not calibrated. the
 20160711.png 
  38   Mon Jul 11 17:04:06 2016 AlenaFacilityDaily ProgressVacuum chamber testsAt 5pm the pressure was 6.5e-6 torr.

Checked again at:


9am, pressure was 2e-6
  
  52   Tue Jul 19 17:15:37 2016 GabrieleFacilityDaily ProgressVacuum pressure acquired[Alena, Gabriele]

We connected the analog output
of the vacuum gauge controller to one of
  
  186   Mon Nov 14 11:28:33 2016 GabrieleGeneralVacuumViton padsI added three 1"x1" viton pads
below the base plate, and realigned the entire
optical system to the horizontal reference
 2016-11-14_10.41.47.jpg2016-11-14_10.41.57.jpgviton.png 
  287   Wed Feb 1 15:23:42 2017 GabrieleOpticsNoise huntingWandering line is due to the laserThe wandering line I mentioned in my previous
elog, which is spoiling most of the sensitivity,
turns out to be power noise of the laser. 
 laser_noise_rin.pngUntitled.avi 
  95   Sun Aug 21 13:45:56 2016 GabrieleOpticsDaily ProgressWierd behavior of ring downs and Improved setupThe last two ring downs I measured today
showed a weird behavior of the lowest modes:

 second_ring_downs.pngthird_ring_downs.png2016-08-21_08.46.11.jpg2016-08-21_13.29.24.jpg2016-08-21_13.29.32.jpg 
  413   Wed Aug 16 14:35:05 2017 GabrieleGeneralComputersWorkstation is downWhile I was working, the network connection
went down. I tried to reboot the workstation,
but I won't boot anymore.
  
  418   Fri Aug 18 14:05:36 2017 GabrieleGeneralComputersWorkstation is now upReinstalled Debian 8, all packages and
CDS software.

Everything seems to be working
  
  504   Fri Mar 30 19:12:15 2018 GabrieleGeneralMeasurementsZirconia S1600519 S1600522 S16005652018-03-30


7:10pm in
chamber

S1800634 (Zirconia)
in CR1
S1600519 in CR2
S1600522
  
  2   Fri Jul 13 10:34:35 2012 janoschOpticsCharacterizationcamera imageWe were confused a bit about how the camera
image changes when you move the arm that
holds the camera and lens around the
  
  288   Wed Feb 1 15:35:30 2017 GabrieleGeneralDaily Progressexcitation not working - FIXEDMy bad, a cable was disconnected.




  
  5   Wed Jul 18 18:43:34 2012 janoschOpticsCharacterizationgone with the windHere a little purple video. It starts with
scattering angle around 15deg and stops at
about 80deg. 
 Purple.avi 
  4   Tue Jul 17 18:32:11 2012 janoschOpticsCharacterizationpurple imagesWe have the new 405nm laser pointer. 
The image to the left shows the scattered
light from the red laser, the image to the
 Red_30deg.pngPurple_30deg.png 
  6   Fri Jul 20 18:35:42 2012 janoschOpticsCharacterizationpurple improvements and first uncalibrated BSDF curvesToday we improved alignment of the lens-camera
arm. We discovered earlier that this alignment
affects the amount of "snowfall"
 Purple.mp4Red.mp4Purple_BSDF.pngRed_BSDF.png 
  8   Fri Oct 12 16:23:20 2012 janoschOpticsDaily Progressreassembled setupNothing has happened since Steve, the visiting
highschool teacher, has left. Meanwhile,
some parts of the multi-color BRDF setup
  
  131   Wed Sep 28 10:26:58 2016 ranaGeneralGeneralreferences on ideal glassesSome easy to read reviews on
thin films and ideal glass for people getting
started in this Q measuring game.



  
  1   Wed Jul 11 23:01:01 2012 janoschOpticsCharacterizationstarting the multi-color scatter experimentSteve Maloney, a visiting highschool teacher,
and I have started to set up a new scattering
experiment in the Richter lab. The idea is
 DSCF3148.JPGDSCF3151.JPGDSCF3150.JPG 
  7   Tue Jul 24 10:59:59 2012 janoschOpticsCharacterizationsum of purple and redWe played around with Matlab today. The
first step was to convert light wavelengths
into RGB colors. In this way we can combine
 ImageSum.png 
  41   Thu Jul 14 16:56:00 2016 AlenaFacilityDaily Progresstest vacuum systemPlease see prosidures for pumping down
and venting with air for the test vacuum
chamber here
  
  3   Fri Jul 13 20:53:35 2012 janoschOpticsCharacterizationtwo imagesThe following two pictures were taken from
the same angle with green (left) and red
(right) incident laser at an angle of 15deg
 Green.pngRed.png 
ELOG V3.1.3-