862
Tue Apr 14 12:19:57 2020
Gabriele
General
Measurements
S1600775 S1600784 S1600788 S1600791
2020-04-14
12:18 pm
in chamber
S1600775 in CR1
S1600784
in CR2
S1600788 in CR3
S1600791
863
Tue Apr 14 18:35:59 2020
Gabriele
General
Measurements
S1600785 S1600789
2020-04-14
6:35pm in
chamber
S1600785 in CR1
S1600789
in CR2
6:40pm
864
Thu Apr 16 14:23:11 2020
Gabriele
General
Measurements
S1600775 S1600784 S1600788 S1600791
2020-04-16
2:21 pm
in chamber
S1600775 in CR1
S1600784
in CR2
S1600788 in CR3
S1600791
865
Fri Apr 17 10:18:17 2020
Gabriele
General
Measurements
S1600785 S1600789
2020-04-17
10:17am
in chamber
S1600785 in CR1
S1600789
in CR2
10:20am
866
Thu Apr 23 14:02:25 2020
Gabriele
General
Measurements
S1600776
2020-04-23
2:00pm in
chamber
S1600776 in CR1
2:02pm
roughing pump on
2:12pm turbo
867
Fri Apr 24 10:53:40 2020
Gabriele
General
Measurements
S1600801 S1600802 S1600803 S1600804
2020-04-24
10:51 am
in chamber
S1600801 in CR1
S1600802
in CR2
S1600803 in CR3
S1600804
868
Mon Apr 27 10:26:29 2020
Gabriele
General
Measurements
S1600805 S1600806 S1600807 S1600808
2020-04-24
10:25 am
in chamber
S1600805 in CR1
S1600806
in CR2
S1600807 in CR3
S1600808
869
Thu May 28 11:43:19 2020
Gabriele
General
Measurements
S1600801 S1600802 S1600803 S1600805 S1600806
2020-05-28
11:40 am
in chamber
S1600801 in CR1
S1600802
in CR2
S1600803 in CR3
S1600805
870
Fri May 29 10:10:51 2020
Gabriele
General
Measurements
S1600806
2020-05-28
10:00 am
in chamber
S1600806 in CR1
10:05
am roughing pumps on
10:15 am
871
Tue Jun 2 10:16:40 2020
Gabriele
General
Measurements
S1600801 S1600802
2020-06-02
10:15 am
in chamber
S1600801 in CR1
S1600802
in CR2
10:20 am
872
Fri Jun 5 18:55:27 2020
Gabriele
General
Measurements
S1600803 GaAs
2020-06-05
6:50 pm
in chamber
S1600803 in CR1
GaAs
in CR2
6:55 pm
873
Tue Jun 9 11:04:28 2020
Gabriele
General
Measurements
GaAs S1600805
2020-06-09
11:00 am
in chamber
GaAs in CR1
S1600805
in CR2
11:04 am
874
Mon Jun 15 19:32:31 2020
Gabriele
General
Measurements
S1600803 GaAs
2020-06-15
7:32 pm
in chamber
S1600803 in CR1
GaAs
in CR2
7:36 pm
875
Tue Jun 16 15:43:29 2020
Gabriele
General
Measurements
S1600805
2020-06-16
3:42 pm
in chamber
S1600805 in CR1
3:45
pm roughing pumps on
3:55 pm turbo
876
Thu Jun 18 17:46:51 2020
Gabriele
General
Measurements
S1600806
2020-06-18
5:45 pm
in chamber
S1600806 in CR1
5:50
pm roughing pumps on
6:00 pm turbo
877
Tue Jun 23 16:22:42 2020
Gabriele
General
Measurements
S1600806
2020-06-23
4:20 pm
in chamber
S1600806 in CR1
4:21
pm roughing pumps on
4:31 pm turbo
878
Wed Jun 24 14:17:45 2020
Gabriele
General
Measurements
S1600805 S1600806
2020-06-24
2:26 pm
in chamber
S1600805 in CR1
S1600806
in CR1
2:27 pm
879
Thu Jun 25 08:49:24 2020
Gabriele
General
Measurements
S1600803 S1600805 S1600806
2020-06-25
8:47 am
in chamber
S1600803 in CR1
S1600805
in CR2
S1600806 in CR3
8:49
880
Wed Jul 1 13:43:53 2020
Gabriele
General
Measurements
S1600803 in
2020-07-01
1:42 pm
in chamber
S1600803 in CR1
1:43
pm roughing pumps on
1:53 pm turbo
881
Thu Jul 2 14:43:09 2020
Gabriele
General
Measurements
S1600794 S1600795 S1600796 S1600797
2020-07-02
2:41 pm
in chamber
S1600794 in CR1
S1600795
in CR2
S1600796 in CR3
S1600797
882
Tue Jul 7 15:40:44 2020
Gabriele
General
Measurements
S1600809 S1600810 S160081 S1600812
2020-07-02
3:39 pm
in chamber
S1600809 in CR1
S1600810
in CR2
S1600811 in CR3
S1600812
351
Thu Jun 22 13:16:37 2017
Zach
Electronics
Modeling
Beginning with COMSOL
2017-06-21
4:30 pm-
Installed COMSOL, began modeling current
ESD by creating parameters and the first
352
Thu Jun 22 15:37:20 2017
Zach
Electronics
Modeling
Beginning modeling
2017-06-22
Created
the geometry of the ESD by creating blocks
and joining them with Unions. I then created
353
Fri Jun 23 12:02:12 2017
Zach
Electronics
Modeling
Plots
2017-06-23
I created
plots of the E field and potential from my
rough model of the ESD. This model has 1mm
356
Tue Jun 27 14:17:47 2017
Zach
Electronics
Modeling
Further plots and improving models
2017-06-27
I built
a new model of the ESD to determine whether
or not the spikes in the electric field at
359
Thu Jun 29 16:40:41 2017
Zach
Electronics
Modeling
Accurate model and force profile
2017-06-29
I created
a much more accurate model of the current
ESD setup from the technical drawings. My
360
Fri Jun 30 11:02:18 2017
Zach
Electronics
Modeling
Matching Forces
2017-06-30
I adjusted
the plot parameters slightly so that it only
showed the actual force profile on the sample
361
Fri Jun 30 16:27:56 2017
Zach
Electronics
Modeling
Double Checking Model
2017-06-30
In order
to confirm the accuracy of my model I checked
some easily computable quantities between
363
Wed Jul 5 12:01:51 2017
Zach
Electronics
Modeling
Force plots-Correct plots, force issue
2017-07-05
I sorted
out my mathematical lapse in logic and computed
the correct force profiles in the perpendicular
364
Wed Jul 5 16:40:51 2017
Zach
Electronics
Modeling
Force disparity-improvement
2017-07-05
In order
to improve my data I shrunk the region of
the finer meshing slightly and made the mesh
365
Thu Jul 6 12:08:35 2017
Zach
Electronics
Modeling
Checking physical parameters
2017-07-06
I compared
the electric field and the polarization to
make sure that those calculations made sense.
366
Thu Jul 6 12:48:54 2017
Zach
Electronics
Modeling
Resolving the factor of two
2017-07-06
I resolved the factor
of two from Griffiths' discussion of
dipoles in non-uniform electric fields. The
367
Wed Jul 12 15:08:59 2017
Zach
Electronics
Modeling
Model of actuator and sample
2017-07-12
I am attaching
the first fully functioning model of the
actuator and sample. I cleared both meshes
368
Fri Jul 14 16:43:24 2017
Zach
Electronics
Modeling
Force profile matlab script
2017-07-14
I have completed
a rough, but functioning script that calculates
the modal force profiles. The force values
371
Thu Jul 20 11:37:01 2017
Zach
Electronics
Modeling
Matlab Script
2017-07-20
I believe
my MATLAB script successfully calculates
the force distribution into each of the modes
375
Mon Jul 24 09:13:45 2017
Zach
Electronics
Modeling
Parametric Sweep
2017-07-24
I wrote
a MATLAB script that is capable of sweeping
parameters, the code is attached. The next
378
Tue Jul 25 13:38:30 2017
Zach
Electronics
Modeling
Parametric Sweep of ESD gap
2017-07-25
I completed
a short sweep of the gap between the drive
and the sample, between .5 and 1 mm in .1
379
Wed Jul 26 09:27:40 2017
Zach
Electronics
Modeling
Sweeping the space between ESD and sample
2017-07-26
I ran a
sweep of the gap between the ESD and the
sample, first from .5 mm to 1 mm. That sweep
381
Wed Jul 26 21:22:50 2017
Zach
Electronics
Modeling
Parametric Sweep Results
2017-07-26
I resolved
the major bugs in the parametric sweep scripts
and ran low resolution sweeps of the gap
382
Thu Jul 27 13:37:31 2017
Zach
Electronics
Modeling
Corrected sample gap sweep
2017-07-27
I resolved
a couple more data processing bugs and calculated
a sweep of the ESD-Sample gap from a distance
383
Thu Jul 27 16:56:03 2017
Zach
Electronics
Modeling
Offset Sweep
2017-07-27
I ran a
low resolution sweep of the offset in the
arms of the ESD, the space between the end
386
Tue Aug 1 16:10:42 2017
Zach
Electronics
Modeling
Improved Gap Sweep
2017-08-01
I completed
an improved sweep of the gap between the
ESD arms. I resolved some code issues, since
388
Wed Aug 2 13:47:47 2017
Zach
Electronics
Modeling
Arm width Sweep
2017-08-02
I ran a
sweep of the width of the ESD arms. There
appears to be a linear relationship across
389
Wed Aug 2 15:40:00 2017
Zach
Electronics
Modeling
Parameter diagram
I am posting a diagram of the geometric
parameters that I swept. The only one not
included is the vertical space between the
394
Mon Aug 7 13:19:48 2017
Zach
Electronics
Modeling
Normalized data
2017-08-07
I included
the modal mass factors in the code and renormalized
my data. The normalization has a noticeable
398
Tue Aug 8 16:20:24 2017
Zach
Electronics
Modeling
Rotated ESD
2017-08-08
I rotated
the ESD and calculated it's modal projections
by rotating the data array that MATLAB extracts
399
Wed Aug 9 12:10:47 2017
Zach
Electronics
Modeling
Preliminary improvement from ESD optimization
2017-08-09
I created
a plot of the ratio of the force in the optimized
design to the force in the original design.
400
Wed Aug 9 15:57:28 2017
Zach
Electronics
Modeling
Triangular Geometry
2017-08-09
I compared
the triangular geometry to the original geometry
and the excitation was only improved
401
Wed Aug 9 17:07:57 2017
Zachary
Electronics
Modeling
Optimization Summary
2017-08-09
p.p1 {margin: 0.0px 0.0px
0.0px 0.0px; font: 11.0px 'Helvetica Neue';
6x
402
Thu Aug 10 10:47:54 2017
Zach
Electronics
Modeling
Geometry Ratios
2017-08-10
The attached
plots compare the new and old geometries
with .5 mm and 1 mm sample gaps. They are
Goto page
Previous
1
,
2
,
3
...
16
, 17,
18
Next
ELOG V3.1.3-