Here's a ongoing summary of the substrate aging tests.

S1600619

Mark Optics with polished edges and CO2 polished, stored in the CR0 vacuum chamber.

Measurement date Elog link DCC link
2018/03/01 470 LIGO-S1600619-v5
2018/03/03   LIGO-S1600619-v6
2018/03/09   LIGO-S1600619-v7
2018/03/15   LIGO-S1600619-v8
2018/03/24   LIGO-S1600619-v9

S1600623

Mark Optics with polished edges, stored in standard wafer container in the dessicator cabinet

Measurement date Elog link DCC link
2018/03/01 469 LIGO-S1600623-v4
2018/03/08 480 LIGO-S1600623-v5
2018/03/16 488 LIGO-S1600623-v6

S1600624

Mark Optics with polished edges, stored in standard wafer container in vacuum sealed envelope with dessicant

Measurement date Elog link DCC link
2018/03/01 469 LIGO-S1600624-v4
2018/03/08 480 LIGO-S1600624-v5
2018/03/16 488 LIGO-S1600624-v6

S1600620

Mark Optics with polished edges and CO2 polished, stored in standard wafer container in the dessicator cabinet

Measurement date Elog link DCC link
2018/03/03 473

LIGO-S1600620-v5

2018/03/08 480 LIGO-S1600620-v6
2018/03/16 488 LIGO-S1600620-v7

S1600621

Mark Optics with polished edges, stored in standard wafer container in vacuum sealed envelope with dessicant

Measurement date Elog link DCC link
2018/03/03 473 LIGO-S1600621-v5
2018/03/08 480 LIGO-S1600621-v6
2018/03/16 488 LIGO-S1600621-v7

 

Attachment 1: S1600619_history.png  19 kB  Uploaded Fri Mar 2 11:19:01 2018  | Hide | Hide all
S1600619_history.png
Attachment 2: S1600623_history.png  14 kB  Uploaded Fri Mar 2 11:19:35 2018  | Hide | Hide all
S1600623_history.png
Attachment 3: S1600624_history.png  14 kB  Uploaded Fri Mar 2 11:20:06 2018  | Hide | Hide all
S1600624_history.png
Attachment 4: S1600620_history.png  14 kB  Uploaded Sat Mar 3 10:23:28 2018  | Hide | Hide all
S1600620_history.png
Attachment 5: S1600621_history.png  14 kB  Uploaded Sat Mar 3 10:24:39 2018  | Hide | Hide all
S1600621_history.png
Attachment 6: S1600619_history.png  17 kB  Uploaded Sun Mar 4 08:41:31 2018  | Hide | Hide all
S1600619_history.png
Attachment 7: S1600623_history.png  16 kB  Uploaded Fri Mar 9 14:16:18 2018  | Hide | Hide all
S1600623_history.png
Attachment 8: S1600624_history.png  16 kB  Uploaded Fri Mar 9 14:16:47 2018  | Hide | Hide all
S1600624_history.png
Attachment 9: S1600620_history.png  17 kB  Uploaded Fri Mar 9 14:17:45 2018  | Hide | Hide all
S1600620_history.png
Attachment 10: S1600621_history.png  17 kB  Uploaded Fri Mar 9 14:18:01 2018  | Hide | Hide all
S1600621_history.png
Attachment 11: S1600619_history.png  22 kB  Uploaded Fri Mar 16 11:55:16 2018  | Hide | Hide all
S1600619_history.png
Attachment 12: evolution.png  14 kB  Uploaded Fri Mar 16 11:55:43 2018  | Hide | Hide all
evolution.png
ELOG V3.1.3-