Thu Aug 24 07:40:33 2017, Gabriele, General, Measurements, Excitations with new ESD
|
Fri Aug 25 07:25:32 2017, Gabriele, General, Measurements, Excitations with new ESD
|
Fri Aug 25 19:29:07 2017, Gabriele, General, Measurements, Excitations with new ESD
|
|
Message ID: 425
Entry time: Fri Aug 25 19:29:07 2017
In reply to: 424
|
Author: |
Gabriele |
Type: |
General |
Category: |
Measurements |
Subject: |
Excitations with new ESD |
|
|
New set of excitations after raising the ESD:
- Quiet time before excitation: 1187676942
Excitation broadband: 1187676974
Quiet time after excitation: 1187676996
- Quiet time before excitation: 1187684226
Excitation broadband: 1187684258
Quiet time after excitation: 1187684280
- Quiet time before excitation: 1187691510
Excitation broadband: 1187691542
Quiet time after excitation: 1187691564
- Quiet time before excitation: 1187698794
Excitation broadband: 1187698826
Quiet time after excitation: 1187698848
Q values are now reasonable
. 
Quote: |
The results show very low Q values, so we suspected some issues. Yesterday we openend the chamber and moved the ESD up, as high as possible. New excitation followed:
-
Quiet time before excitation: 1187676942
Excitation broadband: 1187676974
Quiet time after excitation: 1187676996
-
Quiet time before excitation: 1187684226
Excitation broadband: 1187684258
Quiet time after excitation: 1187684280
-
Quiet time before excitation: 1187691510
Excitation broadband: 1187691542
Quiet time after excitation: 1187691564
-
Quiet time before excitation: 1187698794
Excitation broadband: 1187698826
Quiet time after excitation: 1187698848
Quote: |
2017-08-23
- Excitations
-
Quiet time before excitation: 1187577794
Excitation broadband: 1187577826
Quiet time after excitation: 1187577848
-
Quiet time before excitation: 1187585078
Excitation broadband: 1187585111
Quiet time after excitation: 1187585133
-
Quiet time before excitation: 1187592363
Excitation broadband: 1187592395
Quiet time after excitation: 1187592417
-
Quiet time before excitation: 1187599647
Excitation broadband: 1187599679
Quiet time after excitation: 1187599701
-
Quiet time before excitation: 1187606931
Excitation broadband: 1187606964
Quiet time after excitation: 1187606986
-
Quiet time before excitation: 1187614217
Excitation broadband: 1187614249
Quiet time after excitation: 1187614271
|
|
|