40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Coating Ring-down Measurement Lab elog  Not logged in ELOG logo
Message ID: 390     Entry time: Thu Aug 3 11:55:18 2017
Author: Gabriele, Rosalie 
Type: General 
Category: Measurements 
Subject: S1600520 S1600521 S1600523 S1600524 

2017-08-03

  • 11:43am in chamber
    • S1600520 in CR1
    • S1600521 in CR2
    • S1600523 in CR3
    • S1600524 in CR4
  • 11:46am roughing pump on
  • 11:55am turbo pump on
  • Excitations:
    • Quiet time before excitation: 1185835692
      Excitation broadband: 1185835727
      Quiet time after excitation: 1185835752

    • Quiet time before excitation: 1185837582
      Excitation broadband: 1185837617
      Quiet time after excitation: 1185837642

    • Quiet time before excitation: 1185839472
      Excitation broadband: 1185839507
      Quiet time after excitation: 1185839532

    • Quiet time before excitation: 1185841362
      Excitation broadband: 1185841397
      Quiet time after excitation: 1185841422

    • Quiet time before excitation: 1185843252
      Excitation broadband: 1185843287
      Quiet time after excitation: 1185843312

    • Quiet time before excitation: 1185845143
      Excitation broadband: 1185845178
      Quiet time after excitation: 1185845203

    • Quiet time before excitation: 1185847033
      Excitation broadband: 1185847068
      Quiet time after excitation: 1185847093

    • Quiet time before excitation: 1185848923
      Excitation broadband: 1185848958
      Quiet time after excitation: 1185848983

2017-08-04

  • 2:00pm valve closed, pumps off, venting
ELOG V3.1.3-