40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Coating Ring-down Measurement Lab elog  Not logged in ELOG logo
Message ID: 386     Entry time: Tue Aug 1 16:10:42 2017
Author: Zach 
Type: Electronics 
Category: Modeling 
Subject: Improved Gap Sweep 

2017-08-01

  • I completed an improved sweep of the gap between the ESD arms. I resolved some code issues, since it was passing the maximum value not the most extreme, smaller magnitude positive values were being included rather than the strongest force calculation.
  • There are still three modes that show unique behavior relative to the others: 14, 19, and 25. Mode 14 is the (2,2), mode 19 is the (2,3) and mode 25 is (3,2).
  • Plots of the mode shapes are included for reference. The black rectangle represents the region covered by the ESD.