Message ID: 382     Entry time: Thu Jul 27 13:37:31 2017
Author: Zach 
Type: Electronics 
Category: Modeling 
Subject: Corrected sample gap sweep 

2017-07-27

  • I resolved a couple more data processing bugs and calculated a sweep of the ESD-Sample gap from a distance of .5 mm to 1.5 mm. The resulting data behaves far more like I would expect from a force generated by an electric field, it seems to drop off like distance squared. This is a very strong correlation with a good intuitive explanation, and would suggest that it is prudent to place the ESD as close to the sample as possible.
  • I also computed a higher resolution sweep of the gap between the arms of the ESD. It did not resolve the strange behavior at all, so I will investigate coupling into the mode pairs as a possible source.

Attachment 1: Fine_sample_gap.jpg  59 kB  | Hide | Hide all
Fine_sample_gap.jpg
Attachment 3: fine_arm_gap.jpg  65 kB  Uploaded Thu Jul 27 15:23:24 2017  | Hide | Hide all
fine_arm_gap.jpg