Message ID: 381     Entry time: Wed Jul 26 21:22:50 2017
Author: Zach 
Type: Electronics 
Category: Modeling 
Subject: Parametric Sweep Results 

2017-07-26

  • I resolved the major bugs in the parametric sweep scripts and ran low resolution sweeps of the gap between the ESD and sample (Gap Sweep) and the spacing between the ESD arms (ESD Arm Gap Sweep).
  • The arm gap sweep largely behaved in a reasonable way with a maximum excitation at a 1.25 mm gap. However modes 14, 19, and 25 did not follow the general trends and had sharp drops and increases compared to the other modes.
  • The sample gap sweep had less intuitive behavior, all of the modes followed the same general double peak trend that drops to zero when the gap is 1.5 mm. I cannot explain exactly why it is behaving that way, I will run a higher resolution sweep and examine the geometry in greater detail.

 