Message ID: 377     Entry time: Tue Jul 25 11:22:37 2017
Author: Gabriele 
Type: General 
Category: Measurements 
Subject: S1600548 S1600550 S1600538 

2017-07-25

  • 11:12am in chamber (non standard order is not a typo!!)
    • S1600548 in CR1
    • S1600550 in CR2
    • S1600538 in CR3
  • 11:13am roughing pump on
  • 11:22am turbo pump on
  • Excitations:
    • Quiet time before excitation: 1185056320
      Excitation broadband: 1185056355
      Quiet time after excitation: 1185056380

    • Quiet time before excitation: 1185057610
      Excitation broadband: 1185057645
      Quiet time after excitation: 1185057670

    • Quiet time before excitation: 1185058900
      Excitation broadband: 1185058935
      Quiet time after excitation: 1185058960

    • Quiet time before excitation: 1185060190
      Excitation broadband: 1185060226
      Quiet time after excitation: 1185060251

    • Quiet time before excitation: 1185061481
      Excitation broadband: 1185061516
      Quiet time after excitation: 1185061541

    • Quiet time before excitation: 1185062771
      Excitation broadband: 1185062806
      Quiet time after excitation: 1185062831

    • Quiet time before excitation: 1185064061
      Excitation broadband: 1185064096
      Quiet time after excitation: 1185064121

    • Quiet time before excitation: 1185065351
      Excitation broadband: 1185065386
      Quiet time after excitation: 1185065411

2017-07-26

  • 4:05pm valve closed, pumps stopped, venting