Message ID: 376     Entry time: Mon Jul 24 16:06:11 2017
Author: Gabriele 
Type: General 
Category: Measurements 
Subject: S1600530 S1600532 S1600537 S1600539 

2017-07-24

  • 3:55pm installed in chamber
    • S1600530 in CR1
    • S1600532 in CR2
    • S1600537 in CR3
    • S1600539 in CR4
  • 3:58pm roughing pump on
  • 4:06pm turbo pump on
  • Excitations:
    • Quiet time before excitation: 1184986754
      Excitation broadband: 1184986789
      Quiet time after excitation: 1184986814

    • Quiet time before excitation: 1184988044
      Excitation broadband: 1184988079
      Quiet time after excitation: 1184988104

    • Quiet time before excitation: 1184989334
      Excitation broadband: 1184989369
      Quiet time after excitation: 1184989394

    • Quiet time before excitation: 1184990625
      Excitation broadband: 1184990660
      Quiet time after excitation: 1184990685

    • Quiet time before excitation: 1184991915
      Excitation broadband: 1184991950
      Quiet time after excitation: 1184991975

    • Quiet time before excitation: 1184993205
      Excitation broadband: 1184993240
      Quiet time after excitation: 1184993265

    • Quiet time before excitation: 1184994495
      Excitation broadband: 1184994530
      Quiet time after excitation: 1184994555

    • Quiet time before excitation: 1184995785
      Excitation broadband: 1184995820
      Quiet time after excitation: 1184995845

2017-07-25

  • 11:00am valve closed, pumps stopped, venting