40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Coating Ring-down Measurement Lab elog  Not logged in ELOG logo
Message ID: 364     Entry time: Wed Jul 5 16:40:51 2017
Author: Zach 
Type: Electronics 
Category: Modeling 
Subject: Force disparity-improvement 

2017-07-05

  • In order to improve my data I shrunk the region of the finer meshing slightly and made the mesh even smaller and then recalculated the force profiles. This time I tried sampling regions inside the disc rather than immediately at the surface. The attached graphs were sampled at the center of the disc. These two techniques vastly improved the data, now the profiles appear the same, but the magnitudes differ by a factor of 2 again. Previously this was due to an error in my calculation of the force, now I do not believe this to be the case. I will leave my work here for the purposes of my first report, it is an interesting result. I also restricted my data set to the finely meshed box which resolved the earlier data display issue. 