  • I sorted out my mathematical lapse in logic and computed the correct force profiles in the perpendicular direction in both disks. The issue is that now the force profiles don't match up. The fact that there is a measured force distribution for the E^2 case outside the disk is only an artifact of the numerics because it is being calculated only from the electric field data which is defined outside the sample. It can be easily removed for final plots once the force distributions are matched by either redefining the cut plane or putting a data filter specifically on the E^2 plot. The jumps in the E^2 plot suggest that the meshing is still too large, I will try to fix this first, hopefully it will help resolve the difference.