Message ID: 362     Entry time: Wed Jul 5 10:01:29 2017
Author: Gabriele 
Type: General 
Category: Measurements 
Subject: S1600547 S1600548 S1600549 S1600550 

2017-07-05

  • NOTE: at 9:40am switched off turbo pump in CR0 to avoid  vibrations
  • NOTE: boxes are labeled as S1600546/547/548/549 but must be relabeled as S1600547/548/549/550
  • 9:53am, in chamber
    • S1600547 in CR1
    • S1600548 in CR2
    • S1600549 in CR3
    • S1600550 in CR4
  • 9:54am roughing pump on
  • 10:02am turbo pump on
  • Excitations:
    • Quiet time before excitation: 1183323620
      Excitation broadband: 1183323655
      Quiet time after excitation: 1183323680

    • Quiet time before excitation: 1183330910
      Excitation broadband: 1183330945
      Quiet time after excitation: 1183330970

    • Quiet time before excitation: 1183338200
      Excitation broadband: 1183338235
      Quiet time after excitation: 1183338260

    • Quiet time before excitation: 1183345490
      Excitation broadband: 1183345525
      Quiet time after excitation: 1183345550

    • Quiet time before excitation: 1183352780
      Excitation broadband: 1183352815
      Quiet time after excitation: 1183352840

    • Quiet time before excitation: 1183360070
      Excitation broadband: 1183360105
      Quiet time after excitation: 1183360130

    • Quiet time before excitation: 1183367360
      Excitation broadband: 1183367395
      Quiet time after excitation: 1183367420

    • Quiet time before excitation: 1183374650
      Excitation broadband: 1183374685
      Quiet time after excitation: 1183374710

2017-07-06

  • 3:45pm, valve closed, vented, pumps stopped