2016-11-15

  • 4:45pm in chamber, balanced
  • 4:46pm, roughing pump on
  • 4:56pm, turbo pump on
  • Excitations:

    • Quiet time before excitation: 1163303050
      Excitation (1100 Hz) at 1163303082 (60 s)
      1kHz excitation finished
      Excitation (broad band) at 1163303144 (60 s)
      Quiet time after excitation: 1163303206

    • Quiet time before excitation: 1163314036
      Excitation (1100 Hz) at 1163314068 (60 s)
      Excitation (broad band) at 1163314130 (60 s)
      Quiet time after excitation: 1163314192

    • Quiet time before excitation: 1163325022
      Excitation (1100 Hz) at 1163325054 (60 s)
      1kHz excitation finished
      Excitation (broad band) at 1163325116 (60 s)
      Quiet time after excitation: 1163325178

2016-11-16

  • 8:25am pumps off

Results

2016-11-15 A

% Freq        Q               Q (C.I. 95%)        Q (C.I. 95%)
1121.1        5.0944e+06        5.0905e+06        5.0982e+06
1140.0        1.1654e+06        1.1635e+06        1.1673e+06
2570.2        2.6712e+06        2.6699e+06        2.6724e+06
2608.7        9.7800e+05        9.7302e+05        9.8303e+05
4474.9        1.8629e+06        1.8624e+06        1.8634e+06
4538.1        3.2875e+05        3.2846e+05        3.2905e+05
6824.1        1.4823e+06        1.4812e+06        1.4834e+06
6840.2        7.3018e+06        7.2982e+06        7.3055e+06
6893.2        9.2821e+05        9.2713e+05        9.2929e+05
6962.9        4.9646e+04        4.9643e+04        4.9650e+04
9608.9        9.1232e+05        9.1133e+05        9.1332e+05
10308.9        5.1598e+06        5.0344e+06        5.2915e+06
10457.7        4.6941e+05        4.6647e+05        4.7239e+05
12819.2        1.0332e+06        1.0323e+06        1.0342e+06
12939.5        4.1373e+05        4.0825e+05        4.1935e+05
14310.4        3.0088e+06        3.0015e+06        3.0161e+06
16241.1        1.4065e+06        1.3908e+06        1.4227e+06
16251.8        5.8974e+06        5.8741e+06        5.9209e+06
16456.0        5.1136e+05        5.0798e+05        5.1478e+05
18816.0        2.8314e+06        2.7798e+06        2.8850e+06
18986.6        6.7793e+05        6.7791e+05        6.7795e+05
20432.7        1.5260e+05        1.5259e+05        1.5260e+05
20473.7        4.7475e+05        4.7474e+05        4.7476e+05
21560.7        5.5350e+06        5.4921e+06        5.5786e+06
24918.6        7.4993e+05        7.4992e+05        7.4995e+05
29247.5        9.5138e+05        9.5137e+05        9.5140e+05
29340.0        1.1583e+07        1.1439e+07        1.1730e+07
29822.7        8.1204e+05        8.1202e+05        8.1205e+05

2016-11-15 B

% Freq        Q                Q (C.I. 95%)        Q (C.I. 95%)
1121.1        4.6065e+06        4.6038e+06        4.6091e+06
1140.0        8.0197e+05        8.0001e+05        8.0393e+05
2570.2        2.3051e+06        2.3035e+06        2.3067e+06
2608.7        9.1341e+05        9.1205e+05        9.1477e+05
4017.5        2.8194e+04        2.8190e+04        2.8197e+04
4475.0        1.6430e+06        1.6421e+06        1.6440e+06
4538.1        3.2912e+05        3.2849e+05        3.2976e+05
6824.1        1.2995e+06        1.2986e+06        1.3005e+06
6840.2        6.5726e+06        6.5697e+06        6.5756e+06
6893.2        8.6042e+05        8.5868e+05        8.6217e+05
6963.0        5.0409e+04        5.0405e+04        5.0412e+04
9609.0        1.0692e+06        1.0604e+06        1.0782e+06
10309.0        5.1393e+06        4.9409e+06        5.3542e+06
10457.7        4.6470e+05        4.4160e+05        4.9034e+05
12819.3        9.0580e+05        9.0410e+05        9.0750e+05
12939.6        4.0804e+05        3.9544e+05        4.2148e+05
14310.5        2.6132e+06        2.6107e+06        2.6158e+06
16241.2        1.2941e+06        1.2868e+06        1.3015e+06
16251.9        5.9674e+06        5.9536e+06        5.9812e+06
16456.2        7.3080e+05        7.2814e+05        7.3347e+05
18816.1        2.5342e+06        2.5282e+06        2.5402e+06
18987.0        6.3654e+05        6.3652e+05        6.3656e+05
21560.9        5.2433e+06        5.1712e+06        5.3174e+06
21610.4        2.3102e+06        2.3102e+06        2.3103e+06
24918.9        6.6504e+05        6.5864e+05        6.7156e+05
27388.0        4.7256e+06        4.6897e+06        4.7619e+06
29153.6        1.2791e+06        1.2790e+06        1.2791e+06
29248.0        8.4919e+05        8.4918e+05        8.4921e+05
29340.0        1.0910e+07        1.0363e+07        1.1519e+07
31810.6        3.0968e+06        3.0967e+06        3.0968e+06

2016-11-15 C

% Freq        Q               Q (C.I. 95%)        Q (C.I. 95%)
1121.0        4.5968e+06        4.5942e+06        4.5994e+06
1140.0        8.9250e+05        8.9149e+05        8.9352e+05
2570.2        2.2831e+06        2.2817e+06        2.2845e+06
2608.7        8.9996e+05        8.9803e+05        9.0190e+05
4474.9        1.5002e+06        1.4983e+06        1.5021e+06
4538.1        3.2279e+05        3.2220e+05        3.2338e+05
6824.2        1.2882e+06        1.2858e+06        1.2906e+06
6840.3        6.5213e+06        6.5146e+06        6.5281e+06
6893.2        8.6464e+05        8.6311e+05        8.6617e+05
9608.9        1.0570e+06        1.0416e+06        1.0728e+06
10309.0        5.0851e+06        4.9675e+06        5.2084e+06
10457.8        4.5509e+05        4.4305e+05        4.6780e+05
12819.4        9.0619e+05        9.0128e+05        9.1116e+05
12940.0        4.2538e+05        4.2537e+05        4.2540e+05
14310.5        2.5765e+06        2.5717e+06        2.5814e+06
16241.2        1.2956e+06        1.2883e+06        1.3030e+06
16251.8        6.0038e+06        5.9865e+06        6.0211e+06
16456.3        7.4603e+05        7.4232e+05        7.4978e+05
18816.0        2.4942e+06        2.4808e+06        2.5077e+06
18987.0        6.4961e+05        6.4960e+05        6.4963e+05
20432.7        1.4994e+05        1.4993e+05        1.4994e+05
20474.1        4.3164e+05        4.3163e+05        4.3165e+05
21560.8        5.2562e+06        5.1891e+06        5.3251e+06
23792.3        1.9386e+06        1.9386e+06        1.9386e+06
24918.9        6.6629e+05        6.6628e+05        6.6631e+05
27387.9        4.7143e+06        4.6193e+06        4.8134e+06
29149.0        5.6268e+06        5.6267e+06        5.6269e+06
29248.0        8.5279e+05        8.5277e+05        8.5280e+05
29340.2        1.0748e+07        1.0565e+07        1.0937e+07
31811.0        3.0852e+06        3.0852e+06        3.0853e+06

 

 

 

 