40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Coating Ring-down Measurement Lab elog  Not logged in ELOG logo
Message ID: 188     Entry time: Tue Nov 15 10:08:28 2016
Author: Gabriele 
Type: General 
Category: Measurements 
Subject: S1600475 

2016-11-15

  • 10:01am in chamber, balanced
  • 10:03am, roughing pump on
  • 10:21am turbo pump on
  • 11:57am, excitation (3kV, 60s), quiet time before 1163275060, quiet time after 1163275168
  • 2:21pm, excitation (3kV, 60s), quiet time before 1163283684, quiet time after 1163283793
  • 3:27pm, pumps off

Results

2016-11-15 A

% Freq        Q                Q (C.I. 95%)        Q (C.I. 95%)
1111.4        7.0708e+06        7.0599e+06        7.0816e+06
2548.7        1.5867e+06        1.5859e+06        1.5876e+06
4438.1        2.7798e+06        2.7786e+06        2.7810e+06
4502.1        3.2580e+05        3.2004e+05        3.3178e+05
6768.6        2.4624e+06        2.4597e+06        2.4652e+06
6780.9        7.9199e+06        7.9148e+06        7.9250e+06
6841.2        1.7197e+06        1.7187e+06        1.7206e+06
9532.6        2.0042e+06        2.0003e+06        2.0082e+06
10221.8        8.7455e+06        8.7384e+06        8.7526e+06
10370.9        4.7482e+05        4.7142e+05        4.7827e+05
12719.2        1.6940e+06        1.6924e+06        1.6956e+06
12840.1        5.4075e+05        5.3459e+05        5.4704e+05
14190.7        6.7551e+06        6.7451e+06        6.7651e+06
16112.3        7.9161e+06        7.8847e+06        7.9478e+06
18660.2        4.6512e+06        4.6392e+06        4.6633e+06
20318.5        1.2487e+06        1.2411e+06        1.2563e+06
21381.3        8.8036e+06        8.7663e+06        8.8412e+06
23749.2        4.6262e+05        4.6261e+05        4.6263e+05
24133.5        1.1367e+06        1.1367e+06        1.1367e+06
24174.5        1.1856e+06        1.1856e+06        1.1857e+06
24732.5        1.0615e+06        1.0615e+06        1.0615e+06
25308.0        2.8236e+06        2.8235e+06        2.8237e+06
27162.8        4.9157e+06        4.9061e+06        4.9254e+06
29011.1        1.7786e+06        1.7786e+06        1.7787e+06
29094.1        1.0590e+07        1.0533e+07        1.0647e+07
31820.6        1.1840e+06        1.1840e+06        1.1840e+06
32083.0        2.9047e+06        2.9047e+06        2.9048e+06

 

2016-11-15 B

% Freq        Q                Q (C.I. 95%)        Q (C.I. 95%)
1111.4        5.3019e+06        5.2950e+06        5.3088e+06
2548.7        1.5590e+06        1.5539e+06        1.5642e+06
4438.1        1.8590e+06        1.8580e+06        1.8601e+06
4502.1        2.9799e+05        2.9699e+05        2.9901e+05
6768.6        1.5724e+06        1.5702e+06        1.5747e+06
6781.1        5.7773e+06        5.7746e+06        5.7800e+06
6841.3        1.2422e+06        1.2411e+06        1.2432e+06
9532.6        1.2514e+06        1.2433e+06        1.2597e+06
10221.8        5.6805e+06        5.6618e+06        5.6993e+06
10371.1        4.5285e+05        4.4967e+05        4.5607e+05
12719.3        1.0666e+06        1.0651e+06        1.0682e+06
12840.0        5.0460e+05        4.9209e+05        5.1776e+05
14190.7        4.2119e+06        4.1999e+06        4.2240e+06
16111.0        5.1330e+06        5.0960e+06        5.1705e+06
18089.0        9.7188e+05        9.7185e+05        9.7190e+05
18660.4        2.9670e+06        2.9374e+06        2.9973e+06
20318.7        8.0187e+05        7.9553e+05        8.0832e+05
21381.4        6.4885e+06        6.4474e+06        6.5302e+06
24133.0        8.2483e+05        8.2481e+05        8.2485e+05
24174.4        8.3029e+05        8.3027e+05        8.3030e+05
27163.0        3.6182e+06        3.6009e+06        3.6356e+06
28916.0        1.3350e+06        1.3349e+06        1.3350e+06
29094.3        8.9762e+06        8.9139e+06        9.0394e+06
29562.6        3.7546e+05        3.7545e+05        3.7547e+05
31820.5        1.0901e+06        1.0901e+06        1.0901e+06

 

 

ELOG V3.1.3-