40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  Coating Ring-down Measurement Lab elog  Not logged in ELOG logo
Message ID: 177     Entry time: Fri Nov 11 10:29:57 2016
Author: Gabriele 
Type: General 
Category: Measurements 
Subject: S1600454 

Note: Marked at "damaged?" by Alena

2016-11-11

  • 10:28am, in chamber, balanced
  • 10:29am, roughing pump started
  • 10:42am, turbo pump started
  • 12:50am, excitation 2kV, 30s , quiet time before 1162929094+30s, quiet time after 1162929206+30s
    • something happened after ~850 seconds...
  • 1:42pm, excitation 2kV, 30s, quiet time before 1162935703+30s, quiet time after 1162935801+30s
  • 3:07pm, pumps stopped

Results

2016-11-11 A

% Freq        Q                 Q (C.I. 95%)      Q (C.I. 95%)
1113.5        1.1749e+07        1.1593e+07        1.1908e+07
2553.4        4.0388e+06        4.0359e+06        4.0417e+06
4446.6        4.6170e+06        4.6141e+06        4.6199e+06
4514.3        2.9059e+05        2.9012e+05        2.9107e+05
6782.6        1.0254e+06        1.0241e+06        1.0266e+06
6801.5        1.9269e+06        1.9255e+06        1.9282e+06
6860.7        1.3774e+06        1.3769e+06        1.3779e+06
9552.2        1.9909e+06        1.9848e+06        1.9971e+06
10407.0        2.5039e+06        2.5001e+06        2.5078e+06
12746.0        1.1864e+06        1.1843e+06        1.1885e+06
14230.5        8.0322e+05        8.0158e+05        8.0486e+05
16141.9        6.6250e+05        6.5746e+05        6.6761e+05
16160.8        3.9976e+06        3.9902e+06        4.0050e+06
16367.6        1.4247e+06        1.4121e+06        1.4376e+06
18888.5        1.1559e+05        1.1559e+05        1.1560e+05
21839.5        1.0733e+06        1.0733e+06        1.0734e+06
23660.1        5.7483e+05        5.7481e+05        5.7484e+05
24786.0        8.8886e+05        8.8884e+05        8.8887e+05
25534.0        6.0001e+05        6.0000e+05        6.0002e+05
27247.3        1.2955e+06        1.2955e+06        1.2956e+06
28977.5        1.2581e+06        1.2581e+06        1.2581e+06
29076.5        1.2993e+06        1.2934e+06        1.3052e+06
29342.0        1.2664e+06        1.2664e+06        1.2665e+06
31088.0        4.7656e+05        4.7655e+05        4.7657e+05
31713.0        1.6862e+06        1.6862e+06        1.6862e+06

2016-11-11 B

% Freq        Q                 Q (C.I. 95%)      Q (C.I. 95%)
1113.5        4.6063e+06        4.5931e+06        4.6196e+06
2553.5        4.8384e+05        4.7913e+05        4.8864e+05
2594.3        6.9375e+05        6.9006e+05        6.9748e+05
4446.5        3.6254e+06        3.6244e+06        3.6265e+06
4514.3        2.8637e+05        2.8360e+05        2.8918e+05
6782.7        1.6890e+06        1.6826e+06        1.6954e+06
6801.5        3.6093e+06        3.5426e+06        3.6786e+06
6860.7        1.3362e+06        1.3356e+06        1.3368e+06
9552.2        1.6879e+06        1.6392e+06        1.7395e+06
10407.1        2.6518e+06        2.6339e+06        2.6699e+06
12746.1        1.1566e+06        1.1388e+06        1.1750e+06
14230.6        8.4460e+05        8.3550e+05        8.5390e+05
16142.0        6.0038e+05        6.0036e+05        6.0039e+05
16160.9        3.5967e+06        3.5844e+06        3.6090e+06
16367.8        1.0885e+06        1.0782e+06        1.0991e+06
27247.6        1.1635e+06        1.1039e+06        1.2299e+06
28977.8        1.2100e+06        1.2100e+06        1.2100e+06
29076.9        1.7618e+06        1.7392e+06        1.7851e+06
29186.8        3.2163e+06        3.2162e+06        3.2164e+06
29341.5        1.0715e+06        1.0714e+06        1.0715e+06
29680.0        1.1609e+06        1.1608e+06        1.1609e+06
31976.4        1.0149e+06        1.0149e+06        1.0149e+06

 

Attachment 5: spectra.png  37 kB  Uploaded Fri Nov 11 14:55:12 2016  | Hide | Hide all
spectra.png
ELOG V3.1.3-