2016-11-09

  • 9:45am in chamber, balanced
  • 9:46am roughing pump on
  • 9:57am turbo pump on
  • 1:02pm: quiet time before excitation 1162760526, excitation ampl. 3kV, duration ~20s, quiet time after 1162760661
  • 2:25pm, another excitation, quiet time after 1162765583
  • 3:30pm, pumps off

Results

2016-11-08 A

% Freq        Q                 Q (C.I. 95%)      Q (C.I. 95%)
1112.3        1.5917e+07        1.5885e+07        1.5948e+07
1944.9        2.7053e+07        2.6225e+07        2.7935e+07
2512.9        5.8309e+05        5.8297e+05        5.8321e+05
2551.4        6.1779e+05        6.1606e+05        6.1953e+05
4444.4        6.9722e+05        6.9646e+05        6.9798e+05
4471.6        1.6717e+05        1.6715e+05        1.6719e+05
4502.5        5.2860e+04        5.2854e+04        5.2866e+04
4510.2        1.7001e+05        1.6995e+05        1.7008e+05
4518.0        5.2761e+04        5.2755e+04        5.2767e+04
4548.8        1.6907e+05        1.6906e+05        1.6909e+05
6741.5        1.6607e+06        1.6606e+06        1.6608e+06
6780.0        1.6527e+06        1.6523e+06        1.6531e+06
6803.6        9.9399e+06        9.9362e+06        9.9437e+06
6818.5        1.6635e+06        1.6633e+06        1.6636e+06
6856.0        1.2917e+06        1.2866e+06        1.2968e+06
9548.9        6.6037e+05        6.5927e+05        6.6147e+05
10252.2        1.1877e+07        1.1873e+07        1.1881e+07
10406.4        9.5454e+05        9.5449e+05        9.5458e+05
12742.3        2.5129e+05        2.5128e+05        2.5130e+05
14231.9        5.2480e+05        5.2478e+05        5.2482e+05
16143.0        2.1547e+06        2.1546e+06        2.1547e+06
16165.5        9.9736e+06        9.9305e+06        1.0017e+07
16324.1        2.0684e+06        2.0684e+06        2.0685e+06
16362.7        2.0847e+06        2.0838e+06        2.0857e+06
16401.2        2.0931e+06        2.0931e+06        2.0932e+06
18713.5        3.0002e+06        3.0001e+06        3.0002e+06
20305.5        3.7687e+05        3.7686e+05        3.7688e+05
20356.6        5.7487e+05        5.7486e+05        5.7488e+05
21448.8        5.5873e+06        5.5759e+06        5.5988e+06
23660.7        3.4572e+06        3.4454e+06        3.4690e+06
24779.6        6.1454e+05        6.1453e+05        6.1455e+05
27248.5        4.3485e+06        4.3485e+06        4.3486e+06
29080.9        3.2828e+06        3.2828e+06        3.2829e+06
29192.0        1.1073e+07        1.0994e+07        1.1153e+07
29668.3        1.1949e+06        1.1949e+06        1.1949e+06
31978.4        3.9904e+06        3.9904e+06        3.9905e+06

2016-11-09 B

% Freq        Q                 Q (C.I. 95%)      Q (C.I. 95%)
1112.3        1.5872e+07        1.5840e+07        1.5903e+07
1945.0        2.9329e+07        2.8527e+07        3.0177e+07
2224.4        1.6491e+07        1.6262e+07        1.6727e+07
2512.9        7.2946e+05        7.2513e+05        7.3384e+05
2551.5        7.7884e+05        7.7715e+05        7.8054e+05
4444.4        6.8441e+05        6.8422e+05        6.8459e+05
4471.6        1.7717e+05        1.7715e+05        1.7719e+05
4502.5        6.9790e+04        6.9783e+04        6.9798e+04
4510.3        1.7365e+05        1.7357e+05        1.7373e+05
4517.7        6.9972e+04        6.9964e+04        6.9980e+04
4548.8        1.7984e+05        1.7982e+05        1.7986e+05
6741.5        1.7916e+06        1.7915e+06        1.7917e+06
6780.0        1.8821e+06        1.8817e+06        1.8825e+06
6803.6        1.1061e+07        1.1050e+07        1.1071e+07
6818.5        1.8161e+06        1.8160e+06        1.8163e+06
6855.9        1.3496e+06        1.3472e+06        1.3521e+06
9549.0        6.6677e+05        6.6557e+05        6.6798e+05
10252.1        1.1961e+07        1.1945e+07        1.1977e+07
10406.4        9.8990e+05        9.8647e+05        9.9336e+05
12742.4        2.3726e+05        2.3725e+05        2.3727e+05
12829.0        3.7039e+05        3.7038e+05        3.7041e+05
12860.0        1.6576e+05        1.6576e+05        1.6577e+05
12867.9        3.7196e+05        3.6849e+05        3.7549e+05
12875.0        1.6658e+05        1.6657e+05        1.6658e+05
14231.9        5.1978e+05        5.1976e+05        5.1980e+05
16143.0        2.2069e+06        2.2068e+06        2.2069e+06
16165.5        1.0126e+07        1.0110e+07        1.0143e+07
16324.3        2.0036e+06        2.0035e+06        2.0036e+06
16362.7        2.0305e+06        2.0295e+06        2.0316e+06
16401.4        2.0320e+06        2.0319e+06        2.0320e+06
20356.7        5.8725e+05        5.8724e+05        5.8727e+05
21449.0        7.7227e+06        7.6377e+06        7.8096e+06
23660.8        3.2698e+06        3.2604e+06        3.2792e+06
24779.8        6.2124e+05        6.2123e+05        6.2125e+05
27248.5        4.2218e+06        4.2217e+06        4.2219e+06
29081.0        3.3153e+06        3.3152e+06        3.3153e+06
29192.1        1.0923e+07        1.0847e+07        1.1000e+07
29668.0        1.2406e+06        1.2406e+06        1.2407e+06
31978.4        3.5580e+06        3.5580e+06        3.5581e+06

 