Message ID: 159     Entry time: Fri Nov 4 14:56:35 2016
Author: Gabriele 
Type: General 
Category: Measurements 
Subject: S1600451 

2016-11-04

  • 2:45pm: re-aligned optical setup to horizontal reference
  • 2:55pm: installed in chamber, balanced
  • 2:56pm, starting roughing pump
  • 3:06pm, starting turbo pump
  • 4:37pm, excitation at GPS 1162337817: apparently I excited too much and the QPD signals are saturating!

  • 7:58pm: new excitation, amplitude 1kV, duration ~20s. Stopped at ~1162349974. This excitation looks good
  • 9:07pm:Started auto_excite.py script. It will wait 5 hours, then perfom two excitation with above parameters, separated by 3 hours
    • excitations at 1162372099 and 1162382978

2016-11-05

  • pumps stopped at 10:00am

Results

2016-11-04

 

% Freq        Q                 Q (C.I. 95%)      Q (C.I. 95%)
1097.0        1.1219e+07        1.1201e+07        1.1236e+07
2515.7        6.3988e+06        6.2433e+06        6.5622e+06
4379.6        9.6150e+06        9.6117e+06        9.6182e+06
4440.9        3.8684e+06        3.8668e+06        3.8701e+06
6678.8        2.7195e+05        2.7170e+05        2.7220e+05
6696.5        2.9698e+06        2.9684e+06        2.9712e+06
6750.6        1.3442e+07        1.3387e+07        1.3497e+07
6811.9        1.9344e+06        1.9288e+06        1.9402e+06
9403.6        1.4946e+05        1.4945e+05        1.4946e+05
10095.6        2.4035e+06        2.4001e+06        2.4069e+06
10237.1        6.5129e+05        6.4697e+05        6.5567e+05
12545.2        1.1434e+06        1.1392e+06        1.1476e+06
12662.5        1.7179e+06        1.7114e+06        1.7245e+06
15901.4        1.5770e+05        1.5769e+05        1.5770e+05
15914.3        2.6775e+06        2.6703e+06        2.6846e+06
16104.5        1.1722e+07        1.1685e+07        1.1760e+07
18110.0        2.1021e+06        2.0988e+06        2.1054e+06
18430.2        9.4278e+05        9.4276e+05        9.4281e+05
18594.0        4.3087e+06        4.3033e+06        4.3142e+06
21119.0        2.6590e+05        2.6589e+05        2.6590e+05
23305.8        2.9146e+06        2.9069e+06        2.9224e+06
24386.0        5.3982e+06        5.3779e+06        5.4187e+06
24654.5        1.2901e+06        1.2900e+06        1.2901e+06
24705.0        1.0320e+06        1.0319e+06        1.0320e+06
25798.0        2.0084e+06        2.0083e+06        2.0084e+06
26123.0        4.1997e+06        4.1996e+06        4.1998e+06
26831.0        5.9972e+05        5.9971e+05        5.9973e+05
28145.0        6.7827e+06        6.7546e+06        6.8110e+06
28555.7        3.7397e+06        3.7397e+06        3.7398e+06
28642.1        3.2190e+06        3.2189e+06        3.2190e+06
29175.0        2.3940e+06        2.3939e+06        2.3940e+06
29190.7        9.6877e+05        9.6876e+05        9.6879e+05
29885.0        1.1788e+06        1.1788e+06        1.1788e+06
30847.0        9.0157e+06        9.0155e+06        9.0158e+06
32238.4        2.3676e+06        2.3676e+06        2.3677e+06
32489.6        1.8718e+06        1.8718e+06        1.8719e+06

2016-11-05 A

% Freq        Q                 Q (C.I. 95%)      Q (C.I. 95%)
1097.5        1.0150e+07        1.0127e+07        1.0174e+07
2515.7        5.5427e+06        5.5405e+06        5.5448e+06
4341.0        3.9407e+06        3.9204e+06        3.9613e+06
4379.5        3.7580e+06        3.7570e+06        3.7589e+06
4418.3        4.0055e+06        3.9839e+06        4.0272e+06
4479.5        1.8248e+05        1.8246e+05        1.8250e+05
6640.4        3.1482e+06        3.1137e+06        3.1834e+06
6678.8        2.9326e+06        2.9319e+06        2.9334e+06
6696.5        1.2999e+07        1.2995e+07        1.3004e+07
6712.1        1.8502e+06        1.8416e+06        1.8589e+06
6750.6        1.8423e+06        1.8418e+06        1.8428e+06
6789.1        1.8641e+06        1.8557e+06        1.8726e+06
6812.0        1.2882e+05        1.2875e+05        1.2888e+05
9403.7        2.2149e+06        2.2119e+06        2.2178e+06
10095.7        6.7624e+05        6.7532e+05        6.7716e+05
10237.1        8.8267e+05        8.8113e+05        8.8423e+05
12545.3        1.7193e+06        1.7154e+06        1.7231e+06
12662.9        1.3162e+05        1.3162e+05        1.3163e+05
14015.5        7.8470e+06        7.6850e+06        8.0159e+06
14749.0        8.7237e+05        8.7234e+05        8.7240e+05
15901.5        2.6799e+06        2.6757e+06        2.6840e+06
16104.6        1.8324e+06        1.8309e+06        1.8340e+06
18109.3        9.6584e+05        9.6582e+05        9.6587e+05
18430.3        4.5212e+06        4.5195e+06        4.5229e+06
18659.2        2.5315e+06        2.5315e+06        2.5316e+06
19997.4        6.2817e+05        6.2816e+05        6.2819e+05
20036.5        1.3129e+06        1.3129e+06        1.3130e+06
20278.0        6.2428e+05        6.2426e+05        6.2429e+05
21119.1        3.4785e+06        3.4784e+06        3.4786e+06
22490.4        4.4881e+06        4.4880e+06        4.4882e+06
23305.9        5.3494e+06        5.3429e+06        5.3559e+06
24386.2        1.3629e+06        1.3628e+06        1.3629e+06
24654.4        9.2395e+05        9.2393e+05        9.2397e+05
24704.5        1.9166e+06        1.9132e+06        1.9201e+06
26123.2        6.4702e+05        6.4700e+05        6.4703e+05
26831.0        5.9846e+06        5.9684e+06        6.0009e+06
28555.8        2.9833e+06        2.9832e+06        2.9833e+06
28642.1        2.1156e+06        2.1156e+06        2.1157e+06
28742.9        1.0233e+07        1.0233e+07        1.0233e+07
29175.0        9.1788e+05        9.1786e+05        9.1789e+05
29191.0        1.1637e+06        1.1637e+06        1.1637e+06
29885.1        8.3480e+06        8.3478e+06        8.3481e+06
30846.5        2.2345e+06        2.2345e+06        2.2345e+06
31607.5        3.6183e+05        3.6183e+05        3.6184e+05
32489.4        5.7409e+06        5.7408e+06        5.7410e+06

2016-11-05 B

% Freq        Q                 Q (C.I. 95%)      Q (C.I. 95%)
1098.0        8.1698e+06        8.1032e+06        8.2374e+06
2477.0        5.0803e+06        4.9987e+06        5.1646e+06
2515.6        5.5435e+06        5.5413e+06        5.5458e+06
4341.1        3.6399e+06        3.6069e+06        3.6736e+06
4379.6        3.7430e+06        3.7422e+06        3.7439e+06
4418.0        3.6883e+06        3.6647e+06        3.7122e+06
4440.9        1.8011e+05        1.8009e+05        1.8013e+05
6678.7        2.9283e+06        2.9246e+06        2.9320e+06
6696.5        1.2927e+07        1.2908e+07        1.2946e+07
6750.6        1.8937e+06        1.8911e+06        1.8963e+06
6812.1        1.3790e+05        1.3789e+05        1.3791e+05
9365.0        2.2626e+06        2.2625e+06        2.2627e+06
9403.7        2.2105e+06        2.2094e+06        2.2117e+06
10095.5        6.4293e+05        6.4290e+05        6.4296e+05
10237.2        9.2890e+05        9.2885e+05        9.2894e+05
12545.3        1.7237e+06        1.7080e+06        1.7398e+06
15901.4        2.6697e+06        2.6697e+06        2.6698e+06
15914.5        1.1338e+07        1.1245e+07        1.1432e+07
16104.5        1.7841e+06        1.7840e+06        1.7841e+06
18109.5        9.4816e+05        9.4814e+05        9.4819e+05
18430.3        4.6575e+06        4.6555e+06        4.6594e+06
21119.1        3.7468e+06        3.7338e+06        3.7599e+06
23305.9        5.3687e+06        5.3582e+06        5.3792e+06
24386.1        1.3616e+06        1.3616e+06        1.3616e+06
24654.5        9.7495e+05        9.7493e+05        9.7497e+05
24704.4        1.9229e+06        1.9229e+06        1.9230e+06
26831.1        5.8344e+06        5.8342e+06        5.8345e+06
28556.0        3.0677e+06        3.0676e+06        3.0677e+06
29175.2        8.7856e+05        8.7855e+05        8.7858e+05
29190.8        1.1455e+06        1.1454e+06        1.1455e+06
29885.1        8.9158e+06        8.9157e+06        8.9160e+06
30846.6        2.1943e+06        2.1943e+06        2.1944e+06
32489.5        5.2642e+06        5.2641e+06        5.2642e+06

 