S1600439, not annealed, as received from Mark Optics
Installation
- installed and balanced, pump down started at 4:38pm (roughing pump), turbo started at 4:51pm
- removed from the chamber on 10/20 at about 11:00am
Measurements
2016_10_19
- QPD centered at 9:25pm, excited (2000 V, 10 s) at 9:27pm, measurement ongoing.
The spectrum was noise than usual due to the roughing pump. I already found out in the past that I can reduce the noise by tweaking the position of the pump. This time however I wasn't successful.
 

Here are the results:

% Freq Q Qlow (C.I. 95%) Qhi (C.I. 95%)
1111.5 6.0958e+06 6.0641e+06 6.1279e+06
2549.6 3.6416e+06 3.6305e+06 3.6528e+06
4441.7 2.6916e+06 2.6879e+06 2.6953e+06
4512.9 2.1090e+05 2.0993e+05 2.1188e+05
6777.5 1.1797e+06 1.1790e+06 1.1803e+06
6790.9 3.8621e+06 3.8540e+06 3.8701e+06
6858.4 1.2434e+06 1.2295e+06 1.2577e+06
9548.0 1.2177e+05 1.1878e+05 1.2491e+05
10234.6 3.9934e+05 3.9351e+05 4.0535e+05
10399.0 2.8135e+05 2.7455e+05 2.8849e+05
12744.2 1.3145e+06 1.3115e+06 1.3174e+06
14211.3 3.8414e+06 3.8136e+06 3.8696e+06
16123.3 2.0276e+06 2.0181e+06 2.0372e+06
16135.8 5.2811e+06 5.2770e+06 5.2852e+06
16370.0 1.4976e+06 1.4922e+06 1.5031e+06
18689.3 4.2954e+06 4.2738e+06 4.3172e+06
23632.0 2.2796e+06 2.2528e+06 2.3070e+06
24797.4 8.7545e+05 8.5819e+05 8.9341e+05
27214.5 1.2566e+06 1.2374e+06 1.2764e+06
28947.5 1.7367e+06 1.7130e+06 1.7611e+06
29144.0 3.2148e+06 3.1213e+06 3.3142e+06
2016_10_20
- Roughing pump was creating too much noise, switched it off at 8:30am
- Excitation at 8:35am (2000 V, 30 s)
Here are the results:
 

And the measured Q values:

% Freq Q Qlow (C.I. 95%) Qhi (C.I. 95%)
1111.4 6.2206e+06 6.2061e+06 6.2351e+06
2549.6 4.1538e+06 4.1498e+06 4.1579e+06
2592.9 1.0952e+06 1.0887e+06 1.1017e+06
4441.7 2.8521e+06 2.8513e+06 2.8529e+06
4513.0 2.0592e+05 2.0455e+05 2.0730e+05
6777.5 1.1013e+06 1.1006e+06 1.1020e+06
6790.9 3.9913e+06 3.9879e+06 3.9947e+06
6858.2 1.3100e+06 1.3078e+06 1.3122e+06
9547.8 1.2492e+06 1.2469e+06 1.2514e+06
10234.7 3.4336e+06 3.4209e+06 3.4463e+06
10398.7 4.3217e+05 3.2860e+05 6.3104e+05
12744.2 4.5274e+05 4.5177e+05 4.5371e+05
14211.3 2.0254e+06 2.0081e+06 2.0430e+06
16123.0 2.1225e+06 2.1173e+06 2.1276e+06
16135.8 4.6547e+06 4.6529e+06 4.6564e+06
16370.3 1.4781e+06 1.4762e+06 1.4800e+06
18689.2 4.5978e+06 4.5891e+06 4.6064e+06
20299.5 4.1859e+05 4.1375e+05 4.2353e+05
20364.6 1.1099e+06 1.0630e+06 1.1612e+06
21418.2 4.5814e+06 4.5718e+06 4.5911e+06
23631.9 2.8907e+06 2.8700e+06 2.9116e+06
24797.4 1.1241e+06 1.1121e+06 1.1363e+06
27214.5 2.1015e+06 2.0752e+06 2.1285e+06
28947.3 2.1285e+06 2.1162e+06 2.1410e+06
29054.7 1.4873e+06 1.4631e+06 1.5124e+06
29143.8 4.1250e+06 4.1050e+06 4.1453e+06
29647.5 4.5456e+05 4.4215e+05 4.6768e+05
31135.4 7.5136e+05 7.3331e+05 7.7033e+05
32013.4 1.1846e+06 1.1565e+06 1.2140e+06 |