40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 9 of 336  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  13238   Tue Aug 22 02:19:11 2017 gautamUpdateALSALS OLTFsAttachment #1 shows the
results of my measurements tonight (SR785
data in Attachment #2).
 ALS_OLTFs.pdfALS_OLTF_Aug2017.zip 
  13244   Tue Aug 22 23:27:14 2017 ranaUpdateALSALS OLTFsDidn't someone look at what the OLG
req. should be for these servos at some point?
I wonder if we can make a parallel digital
  
  13246   Wed Aug 23 17:22:36 2017 gautamUpdateALSFiber ALS - reinstalledI completed the revamp of the box, and
re-installed the box on the PSL table today.
I think it would be ideal to install this
  
  13254   Fri Aug 25 15:54:14 2017 gautamUpdateALSFiber ALS noise measurement[Kira, gautam]

Attachment #1 - Photo
of the revamped beat setup. The top panel
 IMG_7497.JPGFOL_schematic.pdf20170825_IR_ALS.pdf 
  13255   Fri Aug 25 17:11:07 2017 ranaUpdateALSFiber ALS noise measurementIs it better to mount the box in the PSL
under the existing shelf, or in a nearby
PSL rack?
  
  13257   Sun Aug 27 11:57:31 2017 ranaUpdateALSFiber ALS noise measurementIt seems like the main contribution to
the RMS comes from the high frequency bump.
When using the ALS loop to lock the arm to
  
  13266   Tue Aug 29 02:08:39 2017 gautamUpdateALSFiber ALS noise measurementI was having a chat with EricQ about this
today, just noting some points from our discussion
down here so that I remember to look into
  
  13288   Fri Sep 1 19:15:40 2017 gautamUpdateALSFiber ALS noise measurementSummary:

I
did some work today to see if I could use
 IR_ALS_noise.pdf 
  13325   Thu Sep 21 01:32:00 2017 gautamUpdateALSAUX X Innolight AM measurement running[rana,gautam]

We set up a measurement of the
AUX X laser AM today. Some notes:
 Innolight_AM.pdfInnolight_AM.tar.gzIMG_7599.JPG20170921_203741_TFAG4395A_21-09-2017_115547_FourSquare.pdf 
  13326   Thu Sep 21 01:55:16 2017 ranaUpdateALSX End table of ShameImage #1: No - we do not use magnetic mounts
for beam dumps. Use a real clamp. It has
to be rigid. "its not going anywhere"
 20170921_003143.jpg20170921_002430.jpg20170921_002243.jpg20170921_001906.jpg 
  13327   Thu Sep 21 15:23:04 2017 gautamOmnistructureALSLong cable from LSC->IOO[steve,gautam]

We laid out a 45m long BNC cable
from the LSC rack to the IOO rack via overhead
  
  13333   Tue Sep 26 19:10:13 2017 gautamUpdateALSFiber ALS setup neatened[steve, gautam]

The Fiber ALS box has been installed
on the existing shelf on the PSL table. We
 IMG_7605.JPG 
  13335   Wed Sep 27 00:20:19 2017 gautamUpdateALSMore AM sweepsAttachment #1: Result
of AM sweeps with EX laser crystal at nominal
operating temperature ~ 31.75 C.
 TFAG4395A_26-09-2017_202344_FourSquare.pdflowTemp.tgzTFAG4395A_26-09-2017_231630_FourSquare.pdfhighTemp.tgz 
  13337   Wed Sep 27 23:44:45 2017 gautamUpdateALSProposed PM measurement setupAttachment #1 is
a sketch of the proposed setup to measure
the PM response of the EX NPRO. Previously,
 IMG_7609.JPG 
  13346   Fri Sep 29 11:16:52 2017 SteveUpdateALSY End table correctedThe first Faraday isolater rejected beam
path from the NPRO is fixed.

 
 ETMYf1.jpg 
  13366   Fri Oct 6 17:08:09 2017 SteveUpdateALSX End table beam traps correctedThere are no more double sided tape on
this table.

 
 c1.jpgc2.jpgc3.jpgc4.jpg 
  13502   Thu Jan 4 12:46:27 2018 gautamUpdateALSFiber ALS assayAttachment
#1 is the updated
 FiberALS.pdfFiberALS.svg.zip 
  13519   Tue Jan 9 21:38:00 2018 gautamUpdateALSALS recovery
Aligned IFO to IR.

Ran
dither alignment to maximize arm transmission.
Centered
Oplev reflections onto their respective QPDs
 GreenLockStability.pngALS_OLTFs_20180109.pdfALS_OLTF_data_20180109.tar.bz2 
  13531   Thu Jan 11 14:22:40 2018 gautamUpdateALSFiber ALS assayI did a cursory check of the ALS signal
chain in preparation for commissioning the
IR ALS system. The main elements of this
  
  13534   Thu Jan 11 20:51:20 2018 gautamUpdateALSFiber ALS assayAfter labeling cables I would disconnect,
I pulled the box out of the LSC rack. Attachment
#1 is a picture of the insides of the box
 IMG_5112.JPG 
  13552   Tue Jan 16 21:50:53 2018 gautamUpdateALSFiber ALS assayWith Johannes' help, I re-installed
the box in the LSC electronics rack. In the
end, I couldn't find a good solution
  
  13557   Thu Jan 18 00:35:00 2018 gautamUpdateALSFiber ALS assaySummary:

I
am facing two problems:
 IR_ALS_20180118.pdfC2B4C1DD-6528-4067-9C13-6BD248629AD6.MOV 
  13559   Fri Jan 19 11:34:21 2018 gautamUpdateALSFiber ALS assayI swapped the inputs to the ZHL-3A at the
PSL table - so now the X beat RF signals
from the beat mouth are going through what
 IR_ALS_20180119.pdf 
  13562   Fri Jan 19 23:04:11 2018 gautamUpdateALSFiber ALS assay[rana, kevin, udit, gautam]

quick notes of some discussions
we had today:
  
  13571   Wed Jan 24 00:33:31 2018 gautamUpdateALSFiber ALS assayI did some work on the PSL table today.
Main
 IMG_6866.JPG 
  13573   Wed Jan 24 00:58:59 2018 gautamUpdateALSX Green PDH modulation depthOn Friday, while Udit and I were doing
some characterization of the EX+PSL IR beat
at the LSC rack, I noticed that there were
  
  13574   Wed Jan 24 10:45:14 2018 gautamUpdateALSFiber ALS assayI was looking into the physics of polarization
maintaining fibers, and then I was trying
to remember whether the fibers we use are
  
  13583   Thu Jan 25 13:18:41 2018 gautamUpdateALSFiber ALS assayI was looking at this a little more closely.
As I understand it, the purpose of the audio
differential IF amplifier is:
 preampProposed.pdf 
  13586   Thu Jan 25 23:59:14 2018 gautamUpdateALSFiber ALS assayI tried to couple the PSL pickoff into
the fiber today for several hours, but got
nowhere really, achieved a maximum coupling
  
  13587   Fri Jan 26 20:03:09 2018 gautamUpdateALSFiber ALS assayI think part of the problem was that the
rejected beam from the PBS was not really
very Gaussian - looking at the spot on the
  
  13591   Wed Jan 31 15:45:22 2018 gautamUpdateALSFiber ALS assayAttachment #1 shows the current situation
of the PSL table IR pickoff. It isn't
the greatest photo but it's hard to get
 IMG_6875.JPG 
  13593   Wed Jan 31 16:29:42 2018 gautamUpdateALSModulation depthsI used the Beat
Mouth to make a quick
 PMCmodDepth.pdfXPDH.pdf 
  13594   Wed Jan 31 16:33:53 2018 gautamUpdateALSALS electronics at LSC rack[steve,
gautam]

We installed some 
  
  13595   Wed Jan 31 22:32:11 2018 gautamUpdateALSALS signal chain + power budgetSummary:

 FiberALS_PowerBudget.pdfpreampProposed.pdf 
  13596   Thu Feb 1 01:24:56 2018 gautamUpdateALSD0902745 revamp underwayI effected the change to the Audio IF preamp
stage on channels 3 and 4 (Xarm and Yarm
respectively) using the resistors Steve ordered
 PSLinterlock.png 
  13597   Thu Feb 1 15:31:12 2018 gautamUpdateALSALS signal chain + power budgetSummary:

A
  
  13599   Fri Feb 2 00:26:34 2018 gautamUpdateALSD0902745 revamp underwayI saw some interesting behaviour of the
Audio IF amplifier stage on the demod board
today, by accident. I was testing the board
  
  13600   Fri Feb 2 13:16:55 2018 gautamUpdateALSALS signals whitening switchingWhile setting up for this measurement,
I noticed something odd with the whitening
switching for the ALS channels. For the usual
 ALS_whitening_switching.pdfALS_whitening_switching_works.pdf 
  13606   Mon Feb 5 14:11:01 2018 gautamUpdateALSHuge harmonics in ALS channelsI've been trying to setup for the THD
measuremetn at the LSC rack for a couple
of days now, but am plagued by a problem
 ALSpowerlineHarmonics.pdf2A1B3AC4-4059-416A-AD88-8AB0431D7A55.jpeg 
  13608   Mon Feb 5 22:57:28 2018 gautamUpdateALSHuge harmonics in ALS channelsDid some quick additional checks to figure
out what's going on here.


The SOS/dewhite board for
  
  13609   Tue Feb 6 11:13:26 2018 gautamUpdateALSPossible source of ground loop identifiedI think I've narrowed down the source
of this ground loop. 
 A68AF89C-E8A9-416D-BBD2-A1AD0A51E0B5.jpeg 
  13612   Tue Feb 6 22:55:51 2018 gautamUpdateALSPossible source of ground loop identified[koji, gautam]

We discussed possible solutions
  
  13613   Wed Feb 7 10:16:26 2018 gautamUpdateALSALS signal chain + power budgetAfter emailing the technical team at Menlo,
I have uploaded the more detailed information
they have given me on our wiki.
  
  13616   Wed Feb 7 15:51:15 2018 gautamUpdateALSD0902745 revamp completeSummary of my tests of the demod boards,
post gain modification:


DC tests (supply voltage,
 6613CD37-5014-44AE-B1FE-6F6A8137DF62.jpeg 
  13621   Thu Feb 8 00:33:20 2018 gautamUpdateALSD990694 characterization / THD measurement planI decided to try doing the THD measurement
with a function generator. Did some quick
trials tonight to verify that the measurement
 D990694THD_trial.pdf 
  13622   Thu Feb 8 01:27:16 2018 KojiUpdateALSD990694 characterization / THD measurement plan>
So my question is - should we just cut the
  
  13623   Thu Feb 8 12:00:09 2018 gautamUpdateALSD990694 is NOT differential receivingCorrecting a mistake   
  13625   Thu Feb 8 13:13:14 2018 gautamUpdateALSD990694 pulled outAfter labeling all cables, I pulled out
one of the D990694s in the LSC rack (the
one used for the ALS X signals, it is Rev-B1,
 IMG_5131.JPGIMG_5133.JPGD990694-B_cuttingPlan.pdf 
  13627   Thu Feb 8 18:10:36 2018 gautamUpdateALSD990694 pulled outThis is proving much more challenging than
I thought - while Cut #1 was easy to identify
and execute, my initial plan for Cut #2 seems
  
  13628   Fri Feb 9 13:37:44 2018 gautamUpdateALSTHD measurement trialI quickly put together some code that calculates
the THD from CDS data and generates a plot
(see e.g. Attachment #1).
 THD_trial.pdf 
ELOG V3.1.3-