40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 99 of 344  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  4842   Mon Jun 20 16:44:02 2011 steveUpdateABSLI-P curve of LightWave M126-1064-700 
 Put the serial numbers into
the elog. So we can identify the laser and
  
  1685   Thu Jun 18 23:20:40 2009 robSummaryLSCI-Q ratio with RF detected DARMThis is a ratio of PD1_I to PD1_Q (so a
ratio of the two quadratures of AS166), measured
in an anti-spring state.  It's not flat
 IQratio.jpg 
  6809   Tue Jun 12 23:18:18 2012 yutaUpdateGreen LockingI-Q signals for the beat[Mengyao, Yuta]

 FINEIQplot20120612.pngCOARSEIQplot20120612.pngbeatysetup20120612.png 
  16012   Sat Apr 10 08:51:32 2021 JonUpdateCDSI/O Chassis AssemblyI installed three of the 16-bit ADC adapter
boards assembled
by Koji. Now, the only missing hardware is the
  
  16093   Thu Apr 29 10:51:35 2021 JonUpdateCDSI/O Chassis AssemblySummary

Yesterday I unpacked
and installed the three 18-bit DAC cards
received from Hanford. I then repeated the
  
  16116   Tue May 4 07:38:36 2021 JonUpdateCDSI/O Chassis AssemblyIOP models created

With all
the PCIe issues now resolved, yesterday I
proceeded to build an IOP model for
 Screen_Shot_2021-05-03_at_4.16.06_PM.png 
  16130   Tue May 11 16:29:55 2021 JonUpdateCDSI/O Chassis Assembly


Quote:


 Screen_Shot_2021-05-11_at_3.03.42_PM.png 
  16131   Tue May 11 17:43:09 2021 KojiUpdateCDSI/O Chassis AssemblyDid you match the local PC time with the
GPS time?
  
  17299   Tue Nov 22 15:33:02 2022 TegaUpdateCDSI/O chassis parts inventory[Tega, JC]

We received the following I/O chassis
parts from LLO:
  
  17304   Wed Nov 23 16:12:00 2022 TegaUpdateCDSI/O chassis parts inventory II[Tega, JC]

We picked up the following I/O
chassis components from Downs CDS testing
  
  6814   Wed Jun 13 11:19:05 2012 steveUpdateSUSIDC receptacles clampedThe MC_ IDC 64 pin cables from sat. amplifiers
to junction-interface-board towards 
whitening - dewhitening at the back of rack
 IMG_1341.JPG 
  10113   Mon Jun 30 16:55:24 2014 ericqUpdateGeneralIFO (mostly) alignedIR Alignment of the IFO is recovered!
Green alignment could use some attention. 
Arms
and PRC hold well, powers are within normal
  
  10114   Mon Jun 30 22:06:55 2014 JenneUpdateASCIFO (mostly) aligned - ASS working[Koji, Jenne]
The Yarm ASS is now working (as is
the Xarm ASS).  Both of the TT's pitch
  
  1830   Tue Aug 4 23:03:56 2009 albertoUpdateLockingIFO AlignmentAfter the mini boot fest that Jenne did
today, I checked whether that fixed the overflow
issues we yesterday prevented the alignemnt
  
  1833   Wed Aug 5 09:48:05 2009 albertoUpdateLockingIFO Alignment


   
        
            
 2009-08-09_FSStransPD.png2009-08-09_FSreflPD.png 
  2205   Sun Nov 8 22:50:29 2009 AlbertoUpdateASCIFO AlignmentTonight I aligned the IFO by running the
scripts one by one.
SRC was far off and I had to align
  
  8921   Thu Jul 25 02:53:00 2013 KojiUpdateGeneralIFO Alignment after TT flipping - no progressThere was no progress tonight after Jenne
left. 
I could not find any reasonable fringes
  
  551   Sun Jun 22 21:38:49 2008 robHowToGeneralIFO CONFIGURE
Now that we're getting back into locking,
it's nice to have a stable alignment of the
  
  9807   Mon Apr 14 13:20:45 2014 JenneUpdateLSCIFO Configure screen updated, CARM / DARM scripts addedI have compressed the IFO Configure screen. 
All PRMI things (sideband lock and carrier
lock) are in the PRMI button, all arm things
  
  1693   Wed Jun 24 09:21:19 2009 steveConfigurationVACIFO RGA scan with Maglev & Cryo


   
        
            
 nmagd1ifo.jpgnmagCryopres.jpg 
  14115   Mon Jul 30 11:05:44 2018 gautamUpdateSUSIFO SUS wonkyWhen I came in this morning:


PMC was unlocked.
Seis
BLRMS were off scale.
ITMX OSEM
 IMG_7102.JPG 
  16028   Wed Apr 14 14:52:42 2021 gautamUpdateGeneralIFO StateThe C1:IFO-STATE
variable is actually a bunch (16 to be precise)
 IFOSTATE.png 
  16030   Wed Apr 14 16:46:24 2021 AnchalUpdateGeneralIFO StateThat makes sense. I assumed that IFO-STATE
is configured as you have proposed it to
be configured. This could be implemented
  
  8085   Fri Feb 15 01:41:02 2013 Manasa, YutaSummaryAlignmentIFO aligned and ready for PRMI locking[Yuta, Manasa, Jenne, Jamie, Steve]
IFO aligned and ready for
  
  8086   Fri Feb 15 01:51:43 2013 JenneSummaryAlignmentIFO aligned and ready for PRMI locking 
Yuta and Manasa, you guys are awesome!
Small, inconsequential point: 
  
  10124   Wed Jul 2 16:18:32 2014 JenneUpdateASCIFO aligned, PRMI + 2 arms achievedAfter the meeting, I aligned the IFO to
the IR, and then I aligned the Ygreen to
the Yarm.  I then found the beatnotes
  
  613   Tue Jul 1 12:51:34 2008 JohnSummaryGeneralIFO alignmentRana, Rob, Yoichi, John

The recent computer problems and MZ work
 align080701.png 
  5267   Fri Aug 19 01:46:06 2011 SureshUpdateGeneralIFO alignment[Keiko, Jamie, Kiwamu, Anamaria,
We followed the procedure that we
laid-out in our elog
  
  8070   Tue Feb 12 20:42:36 2013 JamieUpdateAlignmentIFO alignment in prep for in-air PRMIYuta, Manasa, Jamie, Jenne, Steve, Rana
Starting this morning, we removed
the temporary half PRC mirror in front of
  
  8071   Tue Feb 12 20:57:47 2013 JenneUpdateAlignmentIFO alignment in prep for in-air PRMIWe should check MC spot positions to see
what they are. 
Also, I'm not thrilled about the
  
  8073   Tue Feb 12 23:24:17 2013 yutaUpdateAlignmentIFO alignment in prep for in-air PRMI[Manasa, Yuta]

Lot's of alignment work, 
  
  4673   Tue May 10 00:31:28 2011 kiwamuUpdateASCIFO alignment planThe alignment of the interferometer
goes basically step by step.
Tuesday will be an alignment day.
  
  10047   Mon Jun 16 23:15:44 2014 JenneUpdateLSCIFO alignment recoveryI noticed today, and Rana said that he
saw Saturday, that 
 Note_061614_230723_0.jpg 
  10051   Tue Jun 17 17:14:14 2014 ManasaUpdateLSCIFO alignment recovery 1. Recovered MC alignment and locked
it manually after the ottavia cron failed
to help.
  
  10053   Tue Jun 17 21:49:13 2014 JenneUpdateLSCIFO alignment recoveryPRMI locking with REFL33 is fine. 
As it was yesterday, it's a little wobbly
without the ASC (just PRM oplev), but I don't
  
  10055   Wed Jun 18 11:57:44 2014 not JenneUpdateLSCIFO alignment recovery

    

       
            
  
  13967   Thu Jun 14 19:30:12 2018 gautamUpdateGeneralIFO alignment restoredAll optics have been re-aligned. Jon/Johannes
will elog about the work today.
  
  10758   Fri Dec 5 02:44:43 2014 JenneUpdateGeneralIFO alignment shenanigans[Jenne, Q, Diego]
OMG, today sucked alignment-wise. 
Like, wow. 
  
  9342   Tue Nov 5 00:39:43 2013 manasaUpdateIOOIFO alignment tuningInformation acknowledged from Steve:
The last steering mirror mount for
IR on the PSL was swapped for a more robust
 MC_spot.png 
  9589   Fri Jan 31 18:41:25 2014 manasaUpdateGeneralIFO alignment update[EricQ, Gabriele, Manasa]
We found we had lost the Y arm pointing
from yesterday. We tried to recover the pointing
  
  9596   Tue Feb 4 16:43:50 2014 manasaUpdateGeneralIFO alignment update[EricQ, Manasa]
We are close to the end of the vent
except for a couple of issues.
  
  2508   Tue Jan 12 09:37:05 2010 AlbertoUpdateABSLIFO availableI finished measuring the AbsL for this
morning. The IFO is again available.
Please don't mess up with the
  
  11154   Sat Mar 21 05:19:49 2015 JenneUpdateLSCIFO awake[Jenne, Den]

The problem with the ASS
turned out to be a mode that was rung up
 carm_cm_up_zip.sh.gz 
  14284   Wed Nov 7 19:42:01 2018 gautamUpdateGeneralIFO checkup and DRMI locking prepEarlier today, I rebooted a few unresponsive
VME crates (susaux, auxey).

The IMC has been unhappy for a
  
  1619   Fri May 22 00:43:24 2009 robConfigurationComputer Scripts / ProgramsIFO configure scripts for XARM and YARMI edited the configure scripts (those called
from the C1IFO_CONFIGURE screen) for restore
XARM and YARM.  These used to misalign
  
  9722   Tue Mar 11 21:38:43 2014 manasaUpdateComputer Scripts / ProgramsIFO configure scripts in burt modifiedI have modified the IFOconfigure scripts
and the corresponding .req files for the
  
  4515   Tue Apr 12 12:01:30 2011 josephbUpdateGeneralIFO controls, now with 10% less lying (ITMX/ITMY controls swapped)The ITMX/ITMY control swap is complete.
The
steps from this
elog were followed.
  
  14636   Fri May 24 11:47:15 2019 gautamUpdateVACIFO is almost at nominal vacuum[chub, gautam]

Overnight, the pressure of the
main volume only rose by 10 mtorr, so there
 pumpdown_20190524.png 
  1604   Tue May 19 09:34:29 2009 steveConfigurationVACIFO is not pumped & CRYO is being regeneratedMorning Vacuum condition: IFO is not being
pumped, P1 pressure is 1.8 mTorr and rising
(see P1 pressure plot of 100 min ).
 cryoreg.jpgcryo30d.jpg 
  2563   Tue Feb 2 22:39:12 2010 JenneUpdatePSLIFO isn't playing nice tonight[Jenne, Kiwamu]
It's been an iffy last few hours
here at the 40m.  Kiwamu, Koji and I
  
ELOG V3.1.3-