  2044   Fri Oct 2 17:00:06 2009 AlbertoUpdateGeneral40m Update - Requirements on the 5x Frequency MultiplierHere's the gist of the requirements on
the 5x frequency multiplier for the upgrade
(see attachemnt - despite the preview down
 DesignOfTheMultiplier1-14-15.pdf 
  2045   Fri Oct 2 18:04:45 2009 robUpdateCDSDTT no good for OMC channelsI took the output of the OMC DAC and plugged
it directly into an OMC ADC channel to see
if I could isolate the OMC DAC weirdness
 omc_dac_dtt.pngomc_dac_sweepTDS.pngomc_dac_dtt_ts.png 
  2047   Sat Oct 3 14:53:24 2009 robUpdateLockingmore progressLate last night after the ETMY settled
down from the quake I made some more progress
in locking, with the handoff to RF CARM succeeding
  
  2048   Mon Oct 5 02:51:08 2009 robUpdateLockingalmost thereWorking well tonight: the handoff of CARM
to RF (REFL2I), successful reduction of CARM
offset to zero, and transition control of
  
  2050   Mon Oct 5 10:41:31 2009 KojiUpdatePSLPSL laser accidentally turned offThe PSL output looks smaller than the incident.
Try to FSS Slow actuator adj of -5.6 (nominal),
instead of -3.5.
  
  2051   Mon Oct 5 13:43:37 2009 ZachUpdatePSLPSL table photosI have been commissioned to take pictures
of the PSL table so that it can be diagrammed.
I am starting now (1:42 pm, 10/5/09).
  
  2052   Mon Oct 5 14:18:41 2009 ZachUpdatePSLPSL table photos

    
  
  2053   Mon Oct 5 14:37:29 2009 AlbertoUpdateABSLAbsolute Length Meaasurement NPRO is onIn the revival of the experiement length
measurement for the recycling cavities, I
turned the auxiliary NPRO back on. The shutter
  
  2054   Mon Oct 5 18:34:26 2009 JenneUpdateAdaptive FilteringAttempts to take a TF of the OAF system[Jenne, Sanjit]
As per Matt's instructions in his
OAF document (elog
 OAF_TF_CORRexc_EMPHout_2.png 
  2055   Mon Oct 5 19:39:26 2009 KojiUpdatePSLPSL laser accidentally turned offI set the FSS slow actuator adj to -5.6
at the lunch time. It gave a little help
at that time.  Now max of the MC Trans is
  
  2056   Tue Oct 6 01:41:20 2009 robUpdateLockingDC Readout Lock acquisition working well tonight. 
Was able to engage CM boost (not superboost)
with bandwidth of ~10kHz.  Also succeeded
  
  2057   Tue Oct 6 10:09:55 2009 ZachUpdatePSLMore picturesI'm back to terrorize the PSL table again.
The pictures I took yesterday were rubbish--today
I'm using a clamp that Steve was nice enough
  
  2058   Tue Oct 6 11:13:53 2009 JenneUpdateAdaptive FilteringAttempts to take a TF of the OAF system

    
        
  
  2061   Wed Oct 7 03:49:49 2009 ranaUpdateAdaptive FilteringAttempts to take a TF of the OAF system Here's a plot of the spectra of the
seismometers and MCL. The coherence shows
which axes are aligned right now: MC1_X is
 Untitled.png 
  2063   Wed Oct 7 07:42:55 2009 ranaUpdateAdaptive FilteringAttempts to take a TF of the OAF systemI remeasured
the OAF time delay using the OAF-TF template
  
  2065   Wed Oct 7 19:23:49 2009 JenneUpdateAdaptive Filtering(Final?) PEM cabling changes

    
        
  
  2066   Wed Oct 7 20:32:21 2009 ranaUpdateAdaptive Filteringextra delay and noise in PEM -> ASS/OAF system[Rana, Jenne]
There is some craziness going on
with the delay in the PEM path for the OAF. 
 a.gif 
  2067   Thu Oct 8 11:10:50 2009 josephb, jenneUpdateComputersEPICs Computer troublesAt around 9:45 the RFM/FB network alarm
went off, and I found c1asc, c1lsc, and c1iovme
not responding. 
  
  2068   Thu Oct 8 11:37:59 2009 josephbUpdateComputersReboot of dcuepics helped, c1susvme1 having problemsPower cycling c1dcuepics seems to have
fixed the EPICs channel problems, and c1lsc,
c1asc, and c1iovme are talking again.
  
  2069   Thu Oct 8 14:41:46 2009 jenneUpdateComputersc1susvme1 is back online

    
        
  
  2074   Fri Oct 9 03:53:56 2009 JenneUpdateAdaptive FilteringRemaking the ASSThe c1ass computer, which is now used for
the OAF system, has many remnants from the
days when it was actually used as an ASS. 
  
  2076   Fri Oct 9 16:36:13 2009 rob UpdateIOOfrequency noise problemI used the XARM as a reference to measure
the frequency noise after the MC.  It's
huge around 4kHz--hundreds of times larger
 freqnoiseaftermc.png 
  2077   Fri Oct 9 17:37:21 2009 JenneUpdateIOOMC2 trans beam is dumpedLast night while noise hunting, Rana found
that the MC2 trans beam has been left for
an unknown length of time just hitting the
  
  2078   Fri Oct 9 17:41:04 2009 JenneUpdatePEMAccelerometers relocated[Sanjit, Jenne]
The set of 6 accelerometers which
were semi-randomly placed underneath the
  
  2079   Sun Oct 11 04:12:44 2009 ranaUpdatePEMAccelerometers relocatedSome of these channels are not like the
others.
 Untitled.png 
  2080   Mon Oct 12 14:51:41 2009 robUpdateComputersc1susvme2 timing problems update update update

    
        
 srmcpu.png 
  2081   Mon Oct 12 17:14:39 2009 robUpdateLockingstabilityLast night, 2+ hour lock, probably broken
by me driving too hard (DARM_EXC).
 transpow.png 
  2083   Mon Oct 12 18:37:55 2009 ZachUpdatePSLInventory--Apologies for the late post--
I was at the PSL table taking an
inventory of the components for a while after
  
  2089   Tue Oct 13 10:31:11 2009 ZachUpdatePSLone more timeI am at the PSL table taking what is hopefully
the last set of pictures for the diagram.
Woohoo.
  
  2090   Tue Oct 13 10:50:58 2009 ZachUpdatePSLone more time

    
  
  2092   Wed Oct 14 16:59:37 2009 robUpdateLockingdaytime lockingThe IFO
can now be locked during the daytime. 
  
  2093   Wed Oct 14 23:02:41 2009 ranaUpdateLockingdaytime lockingThis is huge.  a.png 
  2095   Thu Oct 15 02:38:10 2009 rana, robUpdateOMCDark Port Mode Scan using the OMCBottom trace is proportional to the OMC
PZT voltage - top trace is the transmitted
light through the OMC. Interferometer is
 OMC-ModeScan_091015.png 
  2096   Thu Oct 15 02:41:04 2009 ranaUpdateCOCChoice of folding mirrors in the RC cavitiesIn addition to the main mirrors (PRM, SRM)
we will also have fold mirrors (called PR1,
PR2, SR1, SR2). I am curious to see if we
 Picture_9.png 
  2098   Thu Oct 15 12:35:09 2009 ZachUpdatePSLinventoryI'm at the PSL table taking inventory of
the elements I don't have down yet.
  
  2099   Thu Oct 15 12:57:23 2009 ZachUpdatePSLinventory

    
        
  
  2102   Fri Oct 16 10:15:02 2009 steveUpdateIOOIP ang & pos recenteredPointing stability of 4 days. Initial pointing
does not go through suspended optics. It
is launched  right after the Piezo Jena
 ip4d.jpg 
  2106   Fri Oct 16 16:44:39 2009 Alberto, SanjitUpdateComputerselog restartedThis afternoon the elog crashed. We just
restarted it.
  
  2111   Sun Oct 18 22:05:40 2009 kiwamuUpdateLSCLSC timing issueToday
I made a measurement to research the LSC
timitng issue as mentioned on 
 rough.pngdetail.png 
  2113   Sun Oct 18 23:02:03 2009 KojiUpdateLSCLSC timing issueYou yourself told me that tdsdata uses
some downconversion from 32k to 16k!
So, how does the downconversion appears
  
  2114   Mon Oct 19 10:00:52 2009 kiwamuUpdateLSCRE: LSC timing issueOf course I know there is a downconversion
in OMC signal from 32k to 16k.
But I was just wondering if the delay
  
  2116   Mon Oct 19 11:31:55 2009 JenneUpdateAdaptive Filteringextra delay and noise in PEM -> ASS/OAF system

    
        
 PEM-timing_19Oct2009.png 
  2117   Mon Oct 19 13:00:53 2009 MottUpdateGeneralPhase Noise MeasurementHere is the result for the measurement
of the phase noise.  We used the marconi
function generator and compared it with an
 PhaseNoiseWithError.jpgG.jpgPSD.jpg 
  2119   Mon Oct 19 17:12:54 2009 jenneUpdatePEMaccelerometers and seismomters are all good.

    
        
 SeismometersGoodSpectra_19Oct2009.png 
  2120   Mon Oct 19 18:14:28 2009 robUpdateCamerasvideo switch brokenThe Chameleon HB (by Knox) video switch
that we use for routing video signals into
the control room monitors is broken. 
  
  2121   Mon Oct 19 19:37:39 2009 Sanjit, JenneUpdateAdaptive Filteringextra delay and noise in PEM -> ASS/OAF systemRana pointed out that the delay may be
caused by the 110B DAQ, as it integrates
over 2ms (5 clock cycles at 2048Hz on the
 PEM_timingDealy_19OCT09_MCL2PEM2.png 
  2122   Mon Oct 19 23:14:32 2009 kiwamuUpdateLSCLSC timing issueI measured
the noise spectrum of LSC_DARM_IN1 and OMC-LSC_DRIVE_EXC
by using DTT,
 SPE20Hz.pngSPE200Hz.pngSPE2kHz.png 
  2123   Tue Oct 20 02:14:29 2009 robUpdateIOOMC2 alignment bias changedthe mode cleaner was having trouble locking
in a 00 mode, needing several tries. 
I changed the MC2 coil biases, and it seems
  
  2124   Tue Oct 20 10:46:18 2009 steveUpdateIOOclipping IP-ANG beam at ETMX chamberInitial pointing beam is clearly clipping
on 2" pick off mirror in  ETMX
vacuum chamber.
 PA200175.JPGPA200177.JPG 
  2125   Tue Oct 20 11:38:10 2009 rana, rolfUpdateAdaptive Filteringextra delay and noise in PEM -> ASS/OAF systemAn email from Rolf about the delay in
the 110Bs: 
  
ELOG V3.1.3-