  3817   Fri Oct 29 04:24:34 2010 KojiUpdateIOOPMC output increased: need attention[Kevin Koji]
- The PBS alignment increased
the transmitted power
  
  3830   Sat Oct 30 14:35:43 2010 KojiSummaryCDSCDS time delay measurementUnsatisfactory.
Neglecting the digital anti-imaging
 CDS_system_investigation_090323.pdf 
  3839   Mon Nov 1 16:43:24 2010 KojiSummaryCDSCDS time delay measurementUm, Beautiful.   
  3847   Tue Nov 2 16:24:07 2010 KojiUpdateAuxiliary lockingAlignment for the green in the X trans table [Kiwamu Koji]
Today we found the green beam
from the end was totally missing at the vertex.
  
  3851   Wed Nov 3 03:00:47 2010 KojiSummaryGreen Lockingcoarse locked green beat frequencyWow! Great guys!!   
  3874   Sat Nov 6 00:49:04 2010 KojiUpdateIOOIMC table work[Suresh, Koji]
- Removed MCT optics in the
  
  3878   Mon Nov 8 10:37:14 2010 KojiUpdateIOOThe 10% pick-off for MCREFL was replaced to a HR mirrorAs MC2 Trans mon QPD is temporary removed
for fixing, we needed a reference for the
MC alignment.
  
  3885   Wed Nov 10 11:46:19 2010 KojiSummaryIOOlimitation of current MC aligningIt didn't make sense in several points.
1. Is the Faraday aperture really
3mm? The beam has the gaussian radius of
  
  3887   Wed Nov 10 14:28:33 2010 KojiSummaryIOOlimitation of current MC aligning1. Look at the Faraday.
2. Look at the wiki. There is the
optical layout in PNG and PDF.
  
  3895   Thu Nov 11 11:51:30 2010 KojiSummaryCDSfound poor contact of DAC cable, previous A2L results were wrongThe cause is apparent!
The connectors on the cables are wrong!
  
  3901   Thu Nov 11 23:35:23 2010 KojiSummaryCDSfound poor contact of DAC cable, previous A2L results were wrong[Koji / Yuta]
There were
 IMG_3698.jpgbad-boys.pngIMG_3705.jpgIMG_3706.jpg 
  3910   Fri Nov 12 19:24:56 2010 KojiUpdateCDSTest of ADC noise[Koji Yuta]
We found one of the ADC cables were
left unconnected. This left the MC suspensions
  
  3921   Mon Nov 15 14:36:37 2010 KojiUpdatePSLC1PSL rebooted? Has C1PSL rebooted? Has burtrestore been
forgotten? Even without elog?
We found some settings are wrong
  
  3924   Mon Nov 15 15:02:00 2010 KojiSummaryPSLpower measurements around the PMC[Valera Yuta Kiwamu Koji]
Kiwamu burtrestored c1psl.  We measured
the power levels around the PMC.
  
  3955   Fri Nov 19 15:51:50 2010 KojiUpdateElectronicsREFL55 CharacterizationsRF Transimpedance of 200Ohm means the residual
impedance at the resonance (R_res) of 40,
  
  3973   Tue Nov 23 10:48:31 2010 KojiUpdateIOOthe plan of the day[Kiwamu/Koji]
- The tanks are open
Plan
  
  4013   Mon Dec 6 11:57:21 2010 KojiSummaryall down cond.power outageI checked the vacuum system and judged
there is no apparent issue.
The chambers and annulus had been
  
  4056   Wed Dec 15 12:46:18 2010 KojiSummaryIOOFinishing up the vac workWhat else?
v: Edit on Dec 15 10PM
  
  4058   Wed Dec 15 14:23:32 2010 KojiUpdateCDSETMY IO chassis updateGreat!

I wish this board works fine at least for
several days...
  
  4062   Wed Dec 15 23:10:40 2010 KojiUpdateIOOSRM Oplev / Dark Steering mirrors installedI helped the vacuum installation work in
the evening.
- Three steering mirrors after the
  
  4066   Fri Dec 17 00:30:05 2010 KojiUpdateIOOITMY / SRM / BS / PRM OPLEVs aligned[Steve and Koji]
The
invac OPLEV mirrros were aligned
  
  4067   Fri Dec 17 00:55:30 2010 KojiUpdateIOOThe dark port beams reached the AP table[Koji and Kiwamu]
We
obtained two dark port beams on the AP table:
  
  4072   Sat Dec 18 23:33:06 2010 KojiUpdateelogrestartedDid the same.

  
  4073   Sun Dec 19 11:19:42 2010 KojiUpdateelogrestartedDid it again. It seemed that Google bot
came to the elog and tried to obtain  "http://nodus.ligo.caltech.edu:8080/robots.txt".
That was the last of the log.
  
  4076   Mon Dec 20 10:47:29 2010 KojiUpdateIOOPlan for closing the vacuum chambersMonday

    Place the bars on the
  
  4088   Wed Dec 22 15:47:22 2010 KojiUpdateVACTank closing procedure[Jenne Kiwamu Joe Osamu Steve Koji]
Yesterday (21st), we closed the BSC
and the four testmass chambers.
  
  4091   Thu Dec 23 03:15:11 2010 KojiUpdateelogelogd is getting killed by SureshELOG has crashed and I restarted it.
Actually the filtering is not effective
so far as elog is not using apache but has
  
  4096   Thu Dec 23 22:13:50 2010 KojiUpdateGeneralPZT HV turned onThe four IOO PZTs have been turned on in
order to confirm the alignment of the IFO.
Once they are turned on, the spots
  
  4104   Tue Jan 4 11:06:32 2011 KojiUpdateIOOPower into Mode Cleaner increased- Previously MC TRANS was 9000~10000 when
the alignment was good. This means that the
MC TRANS PD is saturated if the full power
  
  4111   Wed Jan 5 10:45:51 2011 KojiUpdateelogrestartedGoogle bot  crashed the elog again.
Then, I found that Google bot (and I) can
crash elogd by trying to show the threaded
  
  4119   Thu Jan 6 00:03:05 2011 KojiUpdateCamerasAligned the Xarm, no big dealNice, nice! 
The power budget for the FPMI is
  
  4121   Thu Jan 6 10:47:11 2011 KojiUpdateelogELOG fixed (re: restarted)Fixed
the 40m elog crashing with the threaded display.
This
morning I found that Google bot crashed the
  
  4140   Wed Jan 12 01:38:52 2011 KojiUpdateIOOPut MC PZT offset onto MC board, instead of on awkward cartI can not think of any reason that the
input impedance of 13kOhm between the pos/neg
inputs produces such a big change at the
  
  4145   Wed Jan 12 22:19:54 2011 KojiUpdateIOOMC flakiness solved[Koji Suresh Kiwamu]
Suresh modified the MC board to have
+5V offset at the output. (To be reported
  
  4155   Fri Jan 14 12:29:57 2011 KojiUpdateLockingNext steps for the greenThese are the next steps for a better operation
of the arm locking. They are suitable for
the day time activities
  
  4156   Fri Jan 14 12:34:08 2011 KojiUpdateLSCX arm locked with C1LSC digital controlMy feeling was that the saturation was
caused by the LSC whitening filter which
was always on.
  
  4169   Wed Jan 19 10:45:00 2011 KojiUpdateElectronicsPOX Transfer FunctionsTF looks fine except for the large peak
at around 200MHz which has been reported
by Rana. The time series and the spectrum
  
  4188   Sat Jan 22 02:03:55 2011 KojiUpdateGreen LockingExamining the stability of VCO PLL at low frequenciesDamn.
If this figure is true, we were looking at
wrong signal. We should look at the feedback
  
  4190   Sat Jan 22 02:23:26 2011 KojiUpdateGreen Lockingsome more progressWhat is the point to use the error instead
of the feedback? It does not make sense to
me.
  
  4193   Mon Jan 24 10:19:21 2011 KojiUpdateGreen LockingX arm locked !Well... The ALS loop is engaged and the
error was suppressed. 
So, how is the IR error signal stabilized
  
  4197   Tue Jan 25 00:09:54 2011 KojiUpdateGeneralJenne laser is at PSL LabI found Tara's elog entry that Jenne laser
is at PSL Lab. 
Since we recently use it frequently,
  
  4202   Tue Jan 25 21:57:59 2011 KojiUpdateGreen LockingSlow servo for green laser1. The dewhitening filter CH6 had no output.
I disconnected the cable and put it to the
monitor out of the AI filter.
 110125_Xend_thermal.pdf 
  4203   Tue Jan 25 22:49:13 2011 KojiUpdateCDSFront End multiple crashSTATUS: 

    Rebooted c1lsc and
c1sus. Restarted fb many times.
  
  4204   Wed Jan 26 02:18:12 2011 KojiUpdateSUSETMX length to angle matrixI have put an offset of 1000 counts to
C1:SUS-ETMX_ALS_OFFSET. This actually misalign
the mirror a lot.
  
  4207   Wed Jan 26 12:03:45 2011 KojiUpdateCDSFront End multiple crashThis is definitely a nice magic to know
as the rebooting causes too much hustles.
Also, you and I should spend an hour
  
  4211   Thu Jan 27 11:04:27 2011 KojiUpdateGreen Lockingbeat freq scanExperiment in the night of Jan 26.
o The arm was locked for the IR beam
and was aligned for it.
 arm_scan.pdfarm_cav_scan3.png110126_ALS_inloop.pdf 
  4215   Thu Jan 27 21:43:37 2011 KojiUpdateGreen Lockingno transmission of ALS signalsNo signal is transmitted from C1:GCV-SCX_ETMX_ALS
(on c1gcv) to C1:GCV-SCX_ETMX_ALS (on c1scx)
I can't find RFM definition for ALS
  
  4221   Fri Jan 28 13:05:56 2011 KojiConfigurationComputersscript path fixedWe had some issues in terms of the script
paths. I have fixed it by replacing /cvs/cds/caltech/scripts
to /cvs/cds/rtcds/caltech/c1/scripts
  
  4228   Sun Jan 30 19:26:03 2011 KojiSummaryGreen LockingPrototype freq dividerA prototype freq divider has been made
which works up to ~40MHz.
74HC4060 (14bit binary ripple counter)
 freq_divider.pdfIMG_3813.jpgIMG_3814.jpg 
  4235   Tue Feb 1 15:09:41 2011 KojiOmnistructureGeneralProjector - fixedThe projector in the controls room has
been fixed the orange blinking of the status
LED.
  
ELOG V3.1.3-