Entry  Tue Sep 20 21:13:39 2011, Suresh, Update, IOO, MC aligned and PSL beam into MC readjusted 
Entry  Tue Sep 20 20:58:35 2011, Anamaria, Configuration, LSC, New AP Table Drawing APtableSep20th.pdf
Entry  Tue Sep 20 17:45:30 2011, kiwamu, Update, CDS, daqd is restarting by hisself ? 
   +  Reply  Tue Sep 20 16:38:25 2011, Keiko, Update, IOO, Small modulation depth 
Entry  Tue Sep 20 15:54:42 2011, kiwamu, Update, Cameras, MC refl camera is available 
   +  Reply  Tue Sep 20 15:39:57 2011, Koji, Update, SUS, free swinging test in vacuum condition 
   +  Reply  Tue Sep 20 14:53:13 2011, Jenne, Update, SUS, Jenne's Scripts started 
Entry  Tue Sep 20 13:57:44 2011, kiwamu, Update, IOO, incident beam to MC aligned 
Entry  Tue Sep 20 03:02:23 2011, Keiko, Update, LSC, locking activity tonight 
Entry  Tue Sep 20 02:21:10 2011, Koji, Update, LSC, LSC MEDM screen cleaning up 
Entry  Mon Sep 19 21:19:25 2011, Katrin, Update, Green Locking, Broadband photodiode characterization current_noise_S3399.pdfidet_S3399.pdfS3399_response.pdfcurrent_noise_S3399_v2.pdfidet_S3399_v2.pdf
Entry  Mon Sep 19 20:56:36 2011, Paul, Summary, SUS, Remaining SRM and ITMY OSEMs calibrations SRM_PITCH_calib_curve.pngSRM_YAW_calib_curve.pngITMY_PITCH_calib_curve.pngITMY_YAW_calib_curve.png
   +  Reply  Mon Sep 19 17:45:39 2011, rana, Update, SUS, Some screens fixed Untitled.png
Entry  Mon Sep 19 16:56:29 2011, Paul, Update, SUS, SRM oplev pitch calibration 
Entry  Mon Sep 19 16:44:16 2011, Keiko, HowTo, LSC, Procedure for the demodulation board check 
Entry  Mon Sep 19 16:20:35 2011, kiwamu, Update, LSC, AS55 whitening gain decreased 
Entry  Mon Sep 19 15:44:32 2011, Mirko, Update, LSC, RF modulation depth measurement P9190138.JPG
Entry  Mon Sep 19 15:30:22 2011, Paul, Update, SUS, SRM oplev OSEM yaw calibration curve SRM_YAW_calib_curve.png
   +  Reply  Mon Sep 19 14:57:36 2011, kiwamu, Summary, IOO, IP POS is back wiring.png
Entry  Mon Sep 19 13:13:10 2011, Paul, Update, SUS, ITMY oplev available for use: SRM not for the moment 
Entry  Mon Sep 19 12:23:30 2011, Paul, Update, SUS, ITMY and SRM oplev beam size reduced + next steps 
   +  Reply  Mon Sep 19 02:08:24 2011, kiwamu, Update, LSC, fixed POP clipping 
Entry  Mon Sep 19 01:38:00 2011, kiwamu, Update, LSC, today's locking activity 
Entry  Mon Sep 19 01:07:32 2011, kiwamu, Update, SUS, f2a filters on ITMs and ETMX f2a_ITMX.pngf2aITMY.pngf2a_ETMX.png
Entry  Sun Sep 18 16:42:00 2011, Koji, Bureaucracy, Environment, Clean up your mess 
Entry  Sun Sep 18 15:57:00 2011, Koji, Update, IOO, The PZT driver engaged to PZT1 
   +  Reply  Sun Sep 18 14:08:52 2011, rana, Update, SUS, Calibration plan for the oplevs 
   +  Reply  Sat Sep 17 14:04:45 2011, Koji, Update, IOO, PZT1 driver in place P9171579.JPGP9171580.JPG
   +  Reply  Sat Sep 17 02:07:10 2011, kiwamu, Update, SUS, ETMX input matrix : bad YAW-SIDE coupling 
Entry  Fri Sep 16 22:11:21 2011, Paul, Update, SUS, ITMY transfer function ITMY_osem_to_oplev_TF.pdf
Entry  Fri Sep 16 21:36:25 2011, Keiko, Update, LSC, POY11 and POY55 were added 
   +  Reply  Fri Sep 16 21:26:12 2011, Keiko, Update, LSC, 3f demodulation board check 
Entry  Fri Sep 16 17:09:07 2011, Paul, Update, SUS, ITMX oplev plan ITMX_oplev_plan.png
Entry  Fri Sep 16 16:34:54 2011, Paul, Update, SUS, ITMY SRM oplev telescope plan ITMY_SRM_telescope.png
   +  Reply  Fri Sep 16 16:29:05 2011, kiwamu, Update, SUS, f2a filters on SRM F2ASRM_Sep16.png
Entry  Fri Sep 16 16:07:28 2011, steve, Update, SAFETY, visitors safety training P1080241.JPG
Entry  Fri Sep 16 14:43:43 2011, Suresh, Update, Computer Scripts / Programs, Changed c1ioo model and restarted fb 
Entry  Fri Sep 16 14:03:53 2011, Paul, Update, SUS, SRM oplev QPD noise measurement SRM_oplev_dark_noise_vs_bright_noise.pdfSRM_ITMY_QPD_dark_noise_comparison.pdf
Entry  Fri Sep 16 03:22:11 2011, Anamaria, Update, LSC, More Refl PDs Work and Attempt at DRMI 
Entry  Fri Sep 16 00:08:30 2011, Paul, Update, SUS, ITMY Oplev QPD dark and bright noise spectra ITMY_oplev_dark_noise_vs_bright_noise.pdf
Entry  Thu Sep 15 22:26:32 2011, Paul, Update, SUS, ITMY Oplev QPD dark noise PSD ITM_dark_QPD_PSD.pdf
Entry  Thu Sep 15 21:56:01 2011, Mirko, Update, CDS, c1oaf check, possible shmem problem c1lsc_to_c1oaf_via_shmem.pngc1oaf_to_c1lsc_via_shmem_fixed_sine_inj_at_100Hz.pngc1oaf_to_c1lsc_via_shmem_white_noise_inj.pngc1pem_to_c1oaf_via_rfm.pngc1lsc_to_c1oaf_via_shmem.png
Entry  Thu Sep 15 20:30:52 2011, Mirko, Update, LSC, Plan for long term optical spec. analyzer setup DSC_3430b.jpg
Entry  Thu Sep 15 20:16:15 2011, jamie, Update, CDS, New c1oaf model installed and running 
   +  Reply  Thu Sep 15 18:31:27 2011, Paul, Update, SUS, ITMY and SRM Oplev current status - comparison with ITMY 
Entry  Thu Sep 15 17:12:29 2011, Mirko, Update, LSC, RF modulation depth measurement 
Entry  Thu Sep 15 17:00:10 2011, Paul and Steve, Update, SUS, New ITMY and SRM oplev plan oplev_plan1.png
Entry  Thu Sep 15 16:45:59 2011, Paul, Update, SUS, ITMY and SRM Oplev status 
Entry  Thu Sep 15 11:37:24 2011, Suresh, Update, Computer Scripts / Programs, fb restarted at Thu Sep 15 11:30:30 PDT 2011 
   +  Reply  Thu Sep 15 07:28:08 2011, steve, Update, SUS, PRM damping restored 