  8752   Wed Jun 26 01:30:31 2013 ranaSummaryPEMVariation in 10-30 Hz seismic RMSFor quite a while (no one knows how long),
we've seen fluctuations in the 10-30 Hz seismic
motion. This shows up as the purple trace
 gur1z_rms.pdfgur1z.pdf 
  8764   Thu Jun 27 15:50:03 2013 JenneUpdatePEMBLRMS are going crazyThe BLRMS are totally crazy today! 
I'm not sure what the story is, since it's
been this way all day (so it's not an earthquake,
 WeirdBLRMSincrease_27June2013_rawSeis.pngWeirdBLRMSincrease_27June2013_lowFreqBLRMS.pngWeirdBLRMSincrease_27June2013_Gur1xBLRMS.png 
  8765   Thu Jun 27 15:58:27 2013 SteveUpdatePEMPSL enclosure particle counts 
 Particle counts were measured
inside the PSL enclosure at 40VAC variac
  
  8773   Thu Jun 27 21:45:48 2013 ranaUpdatePEMBLRMS are going crazyIts an increase in the microseismic peak.
Don't know what its due to though.
 useism.pdf 
  8856   Tue Jul 16 13:48:26 2013 SteveUpdatePEMcranes cleanedKeven and Steve,
The 3 cranes tested and  wiped
off as preparation for upcoming vent.
  
  8925   Thu Jul 25 14:45:06 2013 ranaUpdatePEMGuralp specgram with ligoDV and NDS2 Once you install a matlab newer than
2012a, you can install ligoDV as a matlab
app and get the NDS2 client software for
 a.pdf 
  8954   Thu Aug 1 16:33:39 2013 SujanUpdatePEMGuralp2 seismometer installed at North side of POX table1)Power to the seismometers were turned
down,
2)Guralp2 was moved to North side
 IMG_1213.JPG 
  8987   Thu Aug 8 18:43:12 2013 SujanSummaryPEMOptimally subtracting signals from two seismometers.An exercise of optimally subtracting one
seismometer signal by  another using weiner
filters was done. Results have been summarized
 Results.pdf 
  8988   Thu Aug 8 18:47:41 2013 SujanSummaryPEMUsing weiner filters for subtracting signals MC_L and GUR2_XI used MC_L signal from the Mode Cleaner
as the desired signal with  GUR2_X as witness
signals. I observed good subtraction where
 Results.zip 
  9003   Tue Aug 13 11:04:44 2013 SteveUpdatePEMfluorecent lightsOur fluorecent
lights became obsolete.  We'll have
change fixtures over to some more energy
  
  9098   Tue Sep 3 14:23:21 2013 SteveUpdatePEM earthquakes ~Vancuver, Canada earthquakes: magnitude
6,  5  and more shaking
 
 EQm6&5.png 
  9140   Thu Sep 19 10:24:58 2013 SteveUpdatePEMPRM damping restored after earth quakeLocal m3.8
eq shakes PRM lose.
 eq3.8mLaVerne.png 
  9154   Sun Sep 22 23:04:52 2013 ranaUpdatePEMGuralp needs recentering After seeing all of these spikes
in the BLRMS at high frequency for awhile,
I power cycled the Guralp interface box (@
 seis.pdf 
  9180   Tue Oct 1 10:06:27 2013 SteveUpdatePEMparticle countsHow can we improve the  3xJuly4Cal.pngwhichOne.jpg 
  9181   Tue Oct 1 11:24:02 2013 ranaUpdatePEMparticle counts Probably more important is to establish
quantitatively how particle counts affects
the lock acquisition or noise in the interferometer.
 pepelepew.jpg 
  9192   Thu Oct 3 02:46:58 2013 ranaMetaphysicsPEMUSGS Furlough   ObamaCare_GOP.png 
  9221   Tue Oct 8 11:29:30 2013 SteveUpdatePEMno Janitor day todayThis was the second week without wet mopping
the floor and wet wipe down of the vacuum
envelope.
 dirtyVacpump.jpg 
  9224   Wed Oct 9 15:00:48 2013 SteveUpdatePEMfreshmen tour [Alan, Koji, Manasa]
Record number of 50 freshmen were
given tour of the 40m this afternoon.
 freshmen2013.jpg 
  9253   Fri Oct 18 08:12:08 2013 SteveUpdatePEM1000 days trends   trend1000days.png 
  9254   Fri Oct 18 15:18:49 2013 SteveUpdatePEM particle count peak or ...Sunday evening fireworks. Manasa heard
it.
 PEMcount?.pngPemCountPeak?No.png 
  9257   Tue Oct 22 10:12:33 2013 SteveUpdatePEM south arm AC intake duct checked  The 4th week of no wet mopping
of the floor  and no wet wiping 
the vacuum envelope.
 PEM0.5micron60d.pngsouthArmIntakeNorth.jpgSouthArmMidIntakeWipe.jpg 
  9269   Wed Oct 23 19:14:10 2013 JenneUpdatePEMSeismometer statusAs you may recall, Den designed some nice
seismometer stations for us with the help
of Steve. The granite base was installed
  
  9300   Sun Oct 27 19:19:42 2013 DenUpdatePEMSeismometer status

    

       
            
 TrilliumPlate.PDFGuralpPlate-1_final.pdf 
  9301   Sun Oct 27 23:26:44 2013 ranaUpdatePEMSeismometer status It would be nice if we could use
the existing seismometer cable and place
a 2-terminal temperature sensor within the
  
  9369   Tue Nov 12 23:05:06 2013 ranaUpdatePEMthump noise from particle counter[quote]The particle counter is back on the
IOOC location on a piece of  FOAM 
It needs this isolation, so when the pump
  
  9374   Wed Nov 13 11:30:07 2013 SteveUpdatePEM particle counter MOVEDParticle counter moved from the top of IOOC
to the east wall
 Met1Moved.JPG 
  9489   Wed Dec 18 15:35:48 2013 SteveUpdatePEMexcess seismic noiseThis is not a test. Life can be dangerous
in the 40m Control  Room.
 seismicCar.jpg 
  9556   Wed Jan 15 13:05:30 2014 JenneUpdatePEM4.4 EQ in Fontana, CAIt looks like there was a 4.4 magnitude
earthquake near Fontana, CA around 1:30am
today.  This tripped all of the suspension
  
  9559   Thu Jan 16 08:19:29 2014 SteveUpdatePEM4.4 and 3.8M local earth quakes

    

       
            
 local4.4eq.pnglocal3.8eq.png 
  9591   Mon Feb 3 10:17:14 2014 SteveUpdatePEMdusty surfacesPlease wet WIPE  AP-ISCT.jpgBSC-rim.jpgITMX-ISCT.jpg12daysAtm.png 
  9623   Tue Feb 11 16:49:36 2014 SteveUpdatePEM floor cleaning Keven, Steve
 
The floor was cleaned under the east
  
  9643   Tue Feb 18 10:10:07 2014 SteveUpdatePEM floor cleaning under racks

    

       
            
  
  9675   Tue Feb 25 23:38:05 2014 rana, jenneUpdatePEMGUR1 Z channel excess noise: oscillating Z channelLast night we noticed an excess in the
GUR1Z seis BLRMS on the StripTool. It was
in the 0.1 - 0.3 Hz band. The rumor in the
 gur1z.pdf 
  9689   Tue Mar 4 17:07:27 2014 SteveUpdatePEM floor cleaning under racks

    

       
            
  
  9743   Fri Mar 21 14:59:44 2014 steveUpdatePEMcontroling dustPlease take a look at the table top with
the flashlight before
 IMG_0044.JPG 
  9771   Tue Apr 1 20:56:27 2014 JenneUpdatePEMNo noticeable effect from Chile's M8.2 earthquakeKoji locked the MC, arms, and PRMI, with
no troubles, after the M8.2 earthquake off
the coast of Chile, that happened about 4
  
  9775   Wed Apr 2 09:31:22 2014 SteveUpdatePEMlocal 3.0M earthquake

    

       
            
 local3.0Meq.png8.2MegChili?.png 
  9778   Wed Apr 2 20:13:04 2014 JenneUpdatePEMMore Chile EQs2 more earthquakes in Chile:  a M6.4
and a M7.8. 
We got them about 15 minutes ago
  
  9808   Mon Apr 14 17:59:05 2014 JenneConfigurationPEMNew T-240 cableAs payment for borrowing 2 of our seismometers,
Zach has made us a new Trillium cable, to
go from the granite station to the readout
  
  9914   Tue May 6 09:46:50 2014 steveUpdatePEMcleaning day Keven and Steve,
We cleaned around the Vertex chambers,
PSL and MC2 floor areas.
 120d.png 
  9958   Thu May 15 15:10:02 2014 SteveUpdatePEMseismic activities Our only seismometer is at the east end
now.
Atm1, Ditch Day morning puzzle. The
 DichDay.pngDitchday8am.jpgAztecsGone.jpg 
  9967   Sat May 17 14:48:06 2014 denUpdatePEMyend sei isolation kit is setYend seismometer isolation kit (elog
8461) hosts Guralp seismometer. I made
a cable for inside connection, assembled
 IMG_1405.JPGIMG_1406.JPG 
  9971   Mon May 19 22:44:21 2014 denUpdatePEMxend sei isolation kit is set

    

       
            
  
  10003   Thu May 29 08:43:34 2014 manasaUpdatePEMAnt season already inAnt season has set in. I spotted and killed
 a few ants around the optics
  
  10023   Wed Jun 11 08:57:49 2014 SteveUpdatePEM air cond maintenance tomorrow morning

    

       
            
  
  10075   Thu Jun 19 17:11:52 2014 steveUpdatePEMit is warmer today The PSL HEPA was running at 30VAC-variac.
It is 1 degree C warmer than usual. The HEPA
fan motor turned up to 60 V
 warmertoday.png 
  10119   Wed Jul 2 11:32:44 2014 Jenne, TaraVUpdatePEMStatus of seismometer stations, Yend Guralp moved[Jenne, TaraV]
We had a look this morning at
the status of the seismometer array, so that
  
  10141   Mon Jul 7 16:39:26 2014 SteveUpdatePEMants on the PSL table

    

       
            
  
  10368   Tue Aug 12 13:31:58 2014 JenneUpdatePEMSeismometer cables in place, ready for sensors[TaraV, Jenne]
The short cable from the slab to
the sensor has been assembled and installed
  
  10523   Mon Sep 22 10:18:58 2014 steveUpdatePEMlab temperatures 
 
 summerheat.png 